SWITCH BASIC SPDT 3A 150GF

D2F-T

Manufacturer Part Number
D2F-T
Description
SWITCH BASIC SPDT 3A 150GF
Manufacturer
Omron
Series
D2Fr
Datasheet

Specifications of D2F-T

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
3A @ 125VAC
Actuator Type
Round (Pin Plunger)
Mounting Type
Through Hole
Termination Style
PC Pin
Operating Force
150gf
Actuator
Plunger, Pin
Contact Form
SPDT
Contact Rating
3 Amps at 125 Volts, 2 Amps at 30 Volts
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
D2F-T
D2FT
SW1149
Specifications
■ Characteristics
Note: 1. Data shown are of initial value.
■ Ratings
Note: 1. When using an inductive load or motor load, consult OMRON.
■ Approvals
Contact Omron to obtain standards approvals on specific models.
UL Recognized, CSA Certified
Note: The rated values approved by each of the safety standards
32
Operating speed
Operating frequency
Contact resistance
Insulation resistance
Dielectric strength (See note 2)
Vibration resistance (See note 3)
Shock resistance (See note 3)
Degree of protection
Degree of protection against
electric shock
Proof tracking index (PTI)
Ambient operating temperature
Ambient operating Humidity
Service life
(Consult Omron for test conditions)
Weight
Rated Voltage
125 VAC
30 VDC
Rated voltage
125 VAC
30 VDC
2. The dielectric strength shown in the table indicates a value for models with a separator.
3. For pin plunger models, the values are measured at the free position and total travel position. For the lever models, they are measured
2.
(e.g.UL,CSA) may be different from the performance character-
istics individually defined in this catalog.
at the total travel position.
The ratings apply under the following test conditions: Ambient Temperature = 20
Snap Action Switch
Standard
Force
3 A
2 A
Resistive load
Microvoltage/current (D2F-01 models)
Low force
0.1 A
D2F
Low Force
0.5 A
1 to 500 mm/second (pin plunger models)
Mechanical: 200 operations per minute max.
Electrical: 30 operations per minute max.
General Purpose: 30 mΩ max. (Standard force versions)
Microload:
100 MΩ min. at 500 VDC
600 VAC, 50/60 Hz for 1 minute between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 minute between current-carrying metal parts and ground, and between each
terminal and non-current-carrying metal parts
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Destruction: 1,000 m/s
Malfunction: 300 m/s
IEC IP40
Class I
175
85% max. (for 5° to 35°C)
Mechanical: 1 million operations min. at 60 operations/minute.
Electrical: 30,000 operations min. at 30 operations/minute.
Approx. 0.5 g (pin plunger models)
-25° to 65°C (at 60% RH) with no icing
D2F
1A
D2F-01
0.1 A
- - -
Standard
0.1 A
50 mΩ max. (Low force versions)
100 mΩ max.
2
(approx. 30 g min.) max.
2
(approx. 100G) max.
■ Contact Specifications
Note: Minimum applicable loads are indicated by N standard
Item
Specification
Material
Gap
(Standard value)
Minimum Applicable Load
(See note)
±
2
°
C, Ambient Humidity = 65
reference values. This value represents the failure rate at a
60% (λ
The equation λ
rate of 1/2,000,000 operations can be expected at a reliability
level of 60%.
General-purpose (D2F models)
Low force
1 A
0.5 A
60
) reliability level (JIS C5003).
60
=0.5 x 10
±
5%, Operating frequency = 30 operations/min.
D2F
Crossbar
Silver alloy
0.25 mm
100 mA at 5 VDC 1 mA at 5VDC
-6
/operations indicates that a failure
Standard
3 A
2 A
Gold alloy
D2F-01