MF-R014/250U-0 Bourns Inc., MF-R014/250U-0 Datasheet

PTC Resettable Fuses 250v Max 3Amps Max

MF-R014/250U-0

Manufacturer Part Number
MF-R014/250U-0
Description
PTC Resettable Fuses 250v Max 3Amps Max
Manufacturer
Bourns Inc.
Type
Telecom PTC Resettable Fusesr
Series
MF-RX/250r
Datasheet

Specifications of MF-R014/250U-0

Hold Current
0.14 Amp
Trip Current
0.28 Amp
Current Rating (max)
40 Amps
Resistance
6.5 Ohms
Maximum Voltage
60 VoltsDC
Termination Style
Radial
Mounting Style
Through Hole
Current Rating
0.14 Amp
Dimensions
6 mm L x 4.7 mm W x 10 mm H
Lead Spacing
5.1 mm
Operating Temperature Range
- 40 C to + 85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Operating/Storage Temperature ..............................-40 °C to +85 °C
Maximum Device Surface Temperature
Passive Aging ..........................................................+85 °C, 1000 hours ........................................................±15 % typical resistance change
Humidity Aging ........................................................+85 °C, 85 % R.H. 500 hours ..........................................±15 % typical resistance change
Thermal Shock ........................................................MIL-STD-202F, Method 107G, ........................................±10 % typical resistance change
Solvent Resistance ..................................................MIL-STD-202, Method 215B............................................No change
Lead Solderability ....................................................ANSI/J-STD-002 ..............................................................>95 % coverage
Flammability ............................................................IEC 695-2-2......................................................................No Flame for 60 secs.
Vibration ..................................................................MIL-STD-883C, Method 2007.1, Condition A..................±5 % typical resistance change
Test
Visual/Mech. ......................................................Verify dimensions and materials..................Per MF physical description
Resistance ..........................................................In still air @ 23 °C ........................................Rmin ≤ R ≤ R1max
Time to Trip ........................................................5 times Ihold, Vmax, 23 °C..........................T ≤ typical time to trip (seconds)
Hold Current ......................................................30 min. at Ihold............................................No trip
Trip Cycle Life ....................................................Vmax, Imax, 100 cycles ..............................No arcing or burning
Trip Endurance....................................................Vmax, 48 hours ..........................................No arcing or burning
UL File Number ..................................................E 174545S
CSA File Number ................................................CA 110338
TÜV File Number ................................................R02057213
“U” suffix indicates product without insulation coating.
MF-R008/250U
MF-R008/250
MF-R011/250U
MF-R012/250
MF-R012/250-A
MF-R012/250-C
MF-R012/250-F
MF-R012/250-1
MF-R012/250-2
MF-R012/250U
MF-R014/250
MF-R014/250-A
MF-R014/250-B
MF-R014/250U
MF-R018/250U
in Tripped State......................................................125 °C
Electrical Characteristics
Environmental Characteristics
Test Procedures And Requirements For Model MF-R/250 Series
Model
Operating
Voltage
Max.
(Vdc)
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
Test Conditions
+60°C, 1000 hours
+125 °C to -55 °C,10 times
MF-R/250 Series -
Features
Radial Leaded Devices
High ability to withstand lightning surges
Ideal lightning surge coordination device
Binned and sorted narrow resistance
ranges available
Lead free option available
Agency recognition:
(Vrms)
Volts
Max.
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
Interrupt
Ratings
Max.
Amps
Max.
10.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
(A)
Telecom PTC Resettable Fuses
T V Rheinland
Current
Amps
0.145
0.145
0.145
0.145
Hold
23 °C
0.08
0.08
0.11
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.18
at
I H
Accept/Reject Criteria
Applications
±15 % typical resistance change
±15 % typical resistance change
Customer Premise Equipment (CPE)
Central Office / Telecom Centers (CO)
Access equipment
Ohms
23 °C
Min.
14.0
15.0
5.0
4.0
7.0
5.5
6.0
6.0
8.0
6.0
3.0
3.0
4.5
3.5
0.8
at
Resistance
Initial
Ohms
23 °C
Max.
20.0
22.0
10.5
10.5
10.0
9.0
8.0
9.0
7.5
9.0
6.0
5.5
6.0
6.5
2.0
at
Resistance
One Hour
Post-Trip
Ohms
23 °C
Max.
33.0
33.0
16.0
16.0
16.0
14.0
16.0
16.0
16.0
16.0
12.0
12.0
14.0
12.0
4.0
at

Related parts for MF-R014/250U-0

MF-R014/250U-0 Summary of contents

Page 1

... Lead Solderability ....................................................ANSI/J-STD-002 ..............................................................>95 % coverage Flammability ............................................................IEC 695-2-2......................................................................No Flame for 60 secs. Vibration ..................................................................MIL-STD-883C, Method 2007.1, Condition A..................±5 % typical resistance change Test Procedures And Requirements For Model MF-R/250 Series Test Visual/Mech. ......................................................Verify dimensions and materials..................Per MF physical description Resistance ..........................................................In still air @ 23 °C ........................................Rmin ≤ R ≤ R1max Time to Trip ........................................................5 times Ihold, Vmax, 23 ° ...

Page 2

... Additional Features ■ Assists equipment with meeting ITU-T K.20/K.21/K.45 ■ Assists equipment with meeting Telcordia GR-1089-C Intrabuilding MF-R/250 Series - Thermal Derating Chart - I hold (Amps) Model -40 ˚C -20 ˚C MF-R008/250 0.124 0.110 MF-R011/250U 0.171 0.151 MF-R012/250 0.186 0.165 MF-R014/250 0.255 0.199 MF-R018/250U 0.269 ...

Page 3

... MF-R/250 Series - How to Order 012/250 Multifuse ® Product Designator Series R = Radial Leaded Component Hold Current, Ihold 008-018 (0.08 - 0.18 Amps) Max. Interrupt Voltage, V 250 (250 Volts) Telecom Options U = Uncoated (radial parts only Pre-tripped Resistance Sorted Narrow resistance ranges Resistance Bins of 0.5 ohms ...

Page 4

... MF-R, MF-RX, MF-R/90, MF-R/250, MF-RX/250 & MF-R/600 Series Tape and Reel Specifications Devices taped using EIA468–B/IEC286-2 standards. See table below and Figures 1 and 2 for details. Dimension Description Carrier tape width Hold down tape width: MF-R/600 Hold down tape width: all others ...

Page 5

... MF-R, MF-RX, MF-R/90, MF-R/250, MF-RX/250 & MF-R/600 Series Tape and Reel Specifications Dimension Description Space between flanges less device Arbor hole diameter Core diameter: MF-R, MF-RX, MF-R/90 & MF-R/250 Core diameter: MF-RX/250 & MF-R/600 Box: MF-R, MF-RX, MF-R/90 & MF-R/250 Box: MF-RX/250 ...

Related keywords