78M6612SP-EVM-1 Maxim Integrated Products, 78M6612SP-EVM-1 Datasheet - Page 19

no-image

78M6612SP-EVM-1

Manufacturer Part Number
78M6612SP-EVM-1
Description
Power Management Modules & Development Tools 78M6612 Eval Kit Phase EV Board
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of 78M6612SP-EVM-1

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
UM_6612_044
3.8
Registers can be read via the command line interface by sending a “)” symbol, followed by the register
address (in hexadecimal), and a carriage return <CR> character. Data is returned in hexadecimal.
Example: )26 will read the RMS voltage for Line 2. )26 is equivalent to )26$. Use )26? for the decimal
format.
Rev. 1.0
Address
(hex)
0
1
2
6
7
26
2A
2B
2C
2D
46
47
6A
6B
6C
6D
80
93
94
95
Measurement Results Registers
Variable
Name
TEMP
FREQ
STATUS
VrmsA
WattA
VrmsB
IrmsA
VARA
VAsA
PFA
Vrms3
WattB
IrmsB
VARB
VAsB
PFB
WattT
IrmsT
VART
VAT
Notes
Signed °C
unsigned Hz
boolean
unsigned mv
unsigned mva
unsigned mv
unsigned ma
unsigned mva
unsigned mva
unsigned
unsigned mva
unsigned mva
unsigned ma
unsigned mva
unsigned mva
unsigned
unsigned mva
unsigned ma
unsigned mva
unsigned mva
Table 7: CLI Measurement Results Registers
Description
Temperature delta from 25°C
Line Frequency
Alarms and other stati (see STATUS section)
Line 1 RMS voltage
Line 1 active power (W1)
Line 2 RMS voltage (V2)
Line 1 RMS current (I2)
Line 1 reactive power
Line 1 volt-amperes (Irms x Vrms)
Line 1 Power Factor (0 to 1.0)
Line-to-line RMS voltage
Line 2 active power (W2)
Line 2 RMS current
Line 2 reactive power
Line 2 volt-amperes (Irms x Vrms)
Line 2 power factor (0 to 1.0)
Total active power
Total RMS current
Total reactive power
Total volt-amperes
78M6612 Split Phase Evaluation Board User Manual