MAX2308EGI Maxim Integrated Products, MAX2308EGI Datasheet - Page 11

no-image

MAX2308EGI

Manufacturer Part Number
MAX2308EGI
Description
Modulator / Demodulator CDMA IF VGAs and I-Q Demodulators with V
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX2308EGI

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Note: H = high, L = low, 1 = logic high, 0 = logic low, X = don’t care, blank = independent parameter
When the part initially powers up or changes state, the
synthesizer acquisition time can be reduced by using
the Turbo feature, enabled by the TURBOCHARGE
(TC) control bit. Turbo functionality provides a larger
charge-pump current during acquisition mode. Once
the VCO frequency is acquired, the charge-pump out-
put current magnitude automatically returns to the pre-
programmed state to maintain loop stability and
minimize spurs in the VCO output signal.
The lock detect output indicates when the PLL is
locked with a logic high.
The MAX2306 family incorporates a 3-wire interface for
synthesizer programming and device configuration
(Figure 5). The 3-wire interface consists of clock, data,
and enable signals. It controls the VCO dividers (M1
and M2), reference frequency dividers (R1 and R2),
and a 13-bit control register. The control register is
used to set up the operational modes (Table 4). The
input shift is 17 data bits long and requires a total of 18
clock bits (Figure 6). A single clock pulse is required
before enable drops low to initialize the data bus.
Table 2. MAX2308 Control Register States
OPERATIONAL
SHUTDOWN
SHUTDOWN
STANDBY
MODE
CDMA
FM_IQ
FM_I
3-Wire Interface and Registers
______________________________________________________________________________________
Shutdown pin completely shuts down
chip
0 in shutdown register bit leaves seri-
al port active
0 in standby pin turns off VGA and
modulator only
CDMA operation
FM IQ quadrature operation
FM I operation
CDMA IF VGAs and I/Q Demodulators
RESULT
ACTION
with VCO and Synthesizer
P
N
H
H
H
H
H
L
I
M
S
B
X
X
Whenever the M or R divide register value is pro-
grammed and downloaded, the control register must
also be subsequently updated. This prevents turbolock
from going active when not desired.
The SHDN control bit is notable because it differs from
the SHDN pin. When the SHDN control bit is low, the
registers and serial interface are left active, retaining
the values stored in the latches, while the rest of the
device is shut off. In contrast, the SHDN pin, when low,
shuts down everything, including the registers and seri-
al interface. See Functional Diagram.
Figure 7 shows the programming logic. The 17-bit shift
register is programmed by clocking in data at the rising
edge of CLK. Before the shift register is able to accept
data, it must be initialized by driving it with at least one
full clock cycle at the CLK input with EN high (see
Figure 6). Pulling enable low will allow data to be
clocked into the shift register; pulling enable high loads
the register addressed by A0, A1, and A2, respectively
(Figure 7). Table 5 lists the power-on default values of
all registers. Table 6 lists the charge-pump current,
depending on CP0 and CP1.
X
X
X
X
0
0
0
0
X
X
CONTROL REGISTER
X
X
X
X
M
S
B
X
X
0
0
0
0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0
1
Registers
X
X
1
0
0
X
X
0
1
1
1
L
S
B
X
L
1
1
1
1
11

Related parts for MAX2308EGI