FB00FCY TELEDYNE, FB00FCY Datasheet - Page 4

no-image

FB00FCY

Manufacturer Part Number
FB00FCY
Description
Relay SSR 50mA 3.25V DC-IN 1A 180V DC-OUT
Manufacturer
TELEDYNE
Datasheet
© 2002 TELEDYNE RELAYS
NOTES:
1.
2.
3.
4.
5.
6.
7.
A) BI-DIRECTIONAL AND DC CONFIGURATION (SEE NOTE 4)
Series resistor required to limit input current to 50 mA
max.
The rated input current is 25 mA for all tests unless
otherwise specified.
Surge current is specified for 25°C, 10 cycles maximum at
a 1 Hz repetition rate with 10% duty cycle and 0.1 s.
duration.
Relays may drive loads connected to either positive or
negative referenced power supply lines. Inductive loads
must be diode suppressed.
Continuous load current is rated under the condition of still
air.
To calculate the maximum ON resistance for a given
junction temperature, find the normalized ON resistance
factor (NR) from Figure 4. Calculate the new ON
resistance as follows:
R
Relays are tested in the bi-directional configuration only.
(ON)
INPUT CURRENT VS TURN-ON TIME
= NR X R
B) DC CONFIGURATION (SEE NOTE 4)
WIRING CONFIGURATIONS
(ON)
@ 25°C
FIGURE 2
FIGURE 1
(800) 284-7007 • www.teledynerelays.com
NORMALIZED ON RESISTANCE VS JUNCTION
OUTPUT TURN-ON AND OFF TIMING
LOAD CURRENT DERATING CURVE
FIGURE 4 (SEE NOTE 6)
TEMPERATURE.
FIGURE 3
FIGURE 5
Series FB
FB\072002\Q1
FB 93