Specifications of 9-1393792-9

Contact Arrangement
DPDT
Dc Coil Voltage
24 V
Coil Current
8.33 mA
Mounting
Through Hole
Contact Data
Type: Single button contact, forcibly guided.
Arrangements: 4 NO + 2NC, 3 NO + 3 NC or 5 NO + 1 NC.
Material: Silver-tin oxide.
Expected Mechanical Life: 10 million operations.
Ratings:
Minimum Contact Load: >50mW.
Initial Contact Resistance:
Initial Dielectric Strength
Between Open Contacts: 1,000Vrms.
Between Coil and Contacts: 3,000Vrms.
Between Contact Sets: 3,000Vrms.
Creepage/Clearance: Contact-to-coil: 5.5/5.5mm.
All values are given for coil without preenergization, at 20°C ambient.
At 70°C after preenergization with 1.1 x nominal voltage, the maximum
operating voltage is 85% of nominal.
At 70°C maximum coil voltage is 1.1 x nominal.
• 4 NO + 2NC, 3 NO + 3 NC or 5 NO + 1 NC contacts.
• Polarized, 800mW coil.
• 6 kV surge resistance between poles.
• Well suited for emergency shut-off, machine control, elevator and
Coil Data DC @ 20°C
Nominal Coil Power: 800mW.
Dimensions are shown for
reference purposes only.
Features
escalator control, light barrier control
Nominal
Current: 8A.
Voltage: 250VAC.
Voltage (breaking): 440VAC.
Power (breaking): 2,000VA.
Voltage
VDC
12
15
18
21
24
36
40
48
5
6
9
2,000 ± 10%
2,880 ± 10%
1,620 ± 10%
180 ± 10%
281 ± 10%
405 ± 10%
551 ± 10%
720 ± 10%
Resistance
101 ± 10%
31 ± 10%
45 ± 10%
Ohms
DC
in
Between Contact Sets: 5.5/5.5mm.
≤ 100 millohms/1A/24VDC;
≤ 20 millohms/10mA/5VDC.
Operate
Voltage
Must
VDC
27 .0
30.0
25.0
11.3
13.5
15.8
18.0
3.8
4.5
6.8
9.0
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Drop-out
Voltage
VDC
0.5
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.6
4.0
4.8
Nominal
Current
161.3
133.3
(mA)
89.1
66.7
53.4
44.4
38.1
33.3
22.2
20.0
16.7
Coil
Catalog 1308242
Issued 3-03
SR6 Sensitive
Sensitive “Safety Relay” with six
forcibly guided contacts.
Users should thoroughly review the technical data before selecting a product
part number. It is recommended that users also seek out the pertinent
approvals files of the agencies/laboratories and review them to ensure the
product meets the requirements for a given application.
Operate Data
Must Operate Voltage: See Coil Data table.
Operate Time /Release Time (typical): 11 ms / 3ms.
Switching Rate: 3,600 ops./hr. max. at rated load.
Max. DC Load Breaking Capacity
Initial Insulation Resistance
Between Mutually Insulated Elements: 10 6 ohms.
Environmental Data
Temperature Range: Operating: -20°C to +70°C.
Vibration (10-200 Hz.): NO: 8g; NC: 5g.
Shock (functional) 16ms, half-sine: NO: 8g; NC: 6g.
Mechanical Data
Termination: Printed circuit terminals.
Enclosure (94 V-0 rated): Sealed (RTIII) plastic case.
Weight: 1.06 oz. (30 g) approximately.
Specifications and availability