107201634 Lineage Power, 107201634 Datasheet - Page 11

no-image

107201634

Manufacturer Part Number
107201634
Description
Module DC-DC 1-OUT 5V 10A 50W 9-Pin
Manufacturer
Lineage Power
Type
Step Downr
Datasheet

Specifications of 107201634

Output Current
10 A
Output Voltage
5 V
Input Voltage
28 V
Number Of Outputs
1
Output Power
50 W
Feature Descriptions
Output Voltage Set-Point Adjustment
(Trim)
Figure 21. Circuit Configuration to Increase
Figure 22. Resistor Selection for Increased Output
Output Overvoltage Clamp
The ouput overvoltage clamp consists of control cir-
cuitry, independent of the primary regulation loop, that
monitors the voltage on the output terminals. The con-
trol loop of the clamp has a higher voltage set point
than the primary loop (see Feature specifications
table). this provides a redundant voltage control that
reduces the risk of output overvoltage.
V
ON/OFF
CASE
V
100k
I
I
10M
(+)
(–)
10k
1M
March 2008
Lineage Power
(continued)
0
Output Voltage
Voltage
SENSE(+)
SENSE(–)
% CHANGE IN OUTPUT VOLTAGE (Δ%)
2
V
TRIM
V
O
O
(+)
(–)
4
(continued)
6
R
adj-up
8
R
LOAD
10
8-715 (C).d
8-880a
18 Vdc to 36 Vdc Input, 5 Vdc Output; 50 W to 100 W
Overtermperature Protection (Shutdown)
The 100 W module features an overtemperature pro-
tection circuit to safeguard against thermal damage.
The circuit shuts down the module when the maximum
case temperature is exceeded. The module restarts
automatically after cooling.
Thermal Considerations
Introduction
The power modules operate in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation of the unit.
Heat-dissipating components inside the unit are ther-
mally coupled to the case. Heat is removed by conduc-
tion, convection,a nd radiation to the surrounding
environment. Proper cooling can be verified by mea-
suring the case temperature. Peak temperature (Tc)
occurs at the position indicated in Figure 23.
Note: Top view, pin locations are for reference.
Figure 23. Case Temperature Measurement
The temperature at this location should not exceed
100 °C. The output power of the module should not
exceed the rated power for the module as listed in the
Ordering Information table.
Although the maximum case temperature of the power
modules is 100 °C, you can limit this temperature to a
lower value for extremely high reliability.
For additional information on these modules, refer to the
Thermal Management JC-, JFC-, JW-, and JFW-Series
50 W to 150 W Board-Mounted Power Modules Technical
Note (TN97-008EPS).
7.6 (0.3)
Measurements shown in millimeters and (inches).
Location
V
ON/OFF
CASE
V
I
I
(+)
(–)
38.0 (1.50)
+ SEN
– SEN
V
TRIM
V
O
O
(+)
(–)
MEASURE CASE
TEMPERATURE HERE
8-716 (C).f
11