CC109125952 Lineage Power, CC109125952 Datasheet - Page 18

no-image

CC109125952

Manufacturer Part Number
CC109125952
Description
SMD 4.5V/14.0V INPUT, 0.59V/3.63 OUTPUT TR
Manufacturer
Lineage Power
Datasheet

Specifications of CC109125952

Number Of Outputs
1
Output Current
3A
Input Voltage
4.5 to 14V
Screening Level
Industrial
Mounting Style
Surface Mount
Pin Count
10
Package / Case
SMT
Lead Free Status / Rohs Status
Compliant
Data Sheet
November 22, 2010
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should
always be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-
up is shown in Figure 49. The preferred airflow
direction for the module is in Figure 50.
The thermal reference points, T
specifications are also shown in Figure 50. For
reliable operation the temperatures at these points
should not exceed 120
module should not exceed the rated power of the
module (Vo,set x Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
LINEAGE
Wind Tunnel
PWBs
POWER
Figure 49. Thermal Test Setup.
o
C. The output power of the
flow
Air
(0.50)
x
12.7_
(3.0)
76.2_
25.4_
(1.0)
4.5 – 14Vdc input; 0.59Vdc to 5.5Vdc output; 3A output current
ref
used in the
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
12V Pico TLynx
TM
Figure 50. Preferred airflow direction and
locations of hot-spots of the module (Tref).
3A: Non-isolated DC-DC Power Modules
18

Related parts for CC109125952