Description
AC/DC Power Supply Single-OUT 12V 10.3A 125W 14-Pin
Manufacturer
Astec Power
Datasheet

Specifications of LPS203-M

Input Voltage
90 to 264 V
Output Voltage
12 V
Maximum Output Current
10.3 A
Number Of Outputs
1
Maximum Output Power
125 W
Efficiency
86(Typ) %
Input Frequency
47 to 63 Hz
Operating Temperature
0 to 50 °C
Safety
• TUV
• UL
• cULus
• CB
• CE
LPS200-M Series
250 Watts
Total Power:
Input Voltage:
# of Outputs:
Special Features
• Medical and ITE safeties
• Active power factor correction
• 3” x 5” footprint
• Less than 1U high
• EN61000-3-2 compliant
• Remote sense
• Power fail
• Adjustable main output
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection
• Thermal overload protection
• Isolated 12V Fan output
• LPX200 enclosure kit available
60950, 60601-1
60950, 60601-1
60950, 60601-1
Certificate & report
Mark (LVD)
125 - 250 Watts
90 - 264 Vac
Single
Electrical Specifications
Input
Input ra nge:
Frequency:
Inrush current:
Efficiency:
EMI/RFI:
Power factor:
Safety ground
leakage current:
Output
Maximum power:
Adjustment range:
Fan output:
Hold-up time:
Overload protection:
Overvoltage protection: 15-50% above nominal output
Logical Control
Power failure:
Remote sense:
90 - 264 Vac; 120 - 300 Vdc
47-63 Hz
50 A max., cold start @ 25 °C
86% typical at full load
FCC Class B conducted; CISPR22 Class B conducted;
EN55022 Class B conducted; VDE0878PT3 Class B conducted
0.99 typical
275 uA @ 50/60 Hz, 264 Vac input
125 W for convection (100 W for LPS202-M) ; 250 W (200 W for LPS202-M)
with 30CFM forced air
±10% minimum on the main outputs
12 V @ 0.5 A convection, @ 1 A forced air isolated, ±10%
16 ms @ 250 W load, 120 Vac input
Short circuit protection on all outputs. Case overload protected @ 110-160%
above rating
Open collector logic signal goes high 100-500 msec after main output; it
goes low at least 6 msec before loss of regulation
Compensates for 0.5 V lead drop min. Will operate without remote sense
connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev. 03.08.10_#98
LPS200-M Series
1 of 3

Related parts for LPS203-M

LPS203-M Summary of contents

Page 1

LPS200-M Series 250 Watts Total Power: 125 - 250 Watts Input Voltage 264 Vac # of Outputs: Single Special Features • Medical and ITE safeties • Active power factor correction • 3” x 5” footprint • Less than ...

Page 2

... IEC68-2-6 to the levels of IEC721-3-2 MTBF calculated: 1 million hours at full load and 25 °C ambient conditions. 230 Vac input, Bellcore Ordering Information Model Output Minimum Number Voltage Load LPS202 LPS203 LPS204 LPS205 LPS208 Peak current lasting <30 seconds with a maximum 10% duty cycle 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. ...

Page 3

Mechanical Drawing 3.00 (76.2) 2.55 (64.8) MH1 SK1 3 1 4.55 (115.6) 2 SK2 MH2 0.15 Dia. 4 Places 5.00 (127.0) SK3 1 1.32 (33. 0.197” (5.0) VR1 SK3 Minimum Output Voltage Standoff Height Adjust Pot Embedded ...

Related keywords