MT88E45BN1 Zarlink, MT88E45BN1 Datasheet - Page 4

no-image

MT88E45BN1

Manufacturer Part Number
MT88E45BN1
Description
Caller ID CMOS 3.58MHz 3.3V 20-Pin SSOP Tube
Manufacturer
Zarlink
Datasheet

Specifications of MT88E45BN1

Package
20SSOP
Telecommunication Standards Supported
ANSI/TIA/EIA-716|ETSI/ETS 300 778-1|GR-30|SIN227|SIN242|SR-TSV-002476|TIA/EIA-777
Fabrication Technology
CMOS
Maximum Data Rate
1212 Bd
Typical Operating Supply Voltage
3.3 V
Typical Supply Current
2.8 mA
Minimum Operating Temperature
-40 °C
Maximum Operating Temperature
85 °C
Operating Frequency
3.58 MHz

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT88E45BN1
Manufacturer:
Zarlink
Quantity:
7
Part Number:
MT88E45BN1
Manufacturer:
ZARLINK
Quantity:
595
Advance Information
Pin Description (continued)
Pin # Name
10
11
12
13
14
15
16
17
18
19
20
DR/STD 3-wire FSK Interface Data Ready/CAS Detection Delayed Steering (CMOS Output). Active
ST/GT CAS Detection Steering/Guard Time (CMOS Output/Analog Input). It is used in conjunction
DATA 3-wire FSK Interface Data (CMOS Output). Mark frequency corresponds to logical 1. Space
IN2+
EST
CB1
CB2
GS2
Vdd
IN2-
CD
frequency corresponds to logical 0.
In mode 0 (when the CB0 pin is logic low) the FSK serial bit stream is output to the DATA pin
directly.
In mode 1 (when the CB0 pin is logic high) the start bit is stripped off, the data byte and the trailing
stop bit are stored in a 9 bit buffer. At the end of each word signalled by the DR/STD pin, the
microcontroller should shift the byte out onto the DATA pin by applying 8 read pulses to the DCLK
pin. A 9th DCLK pulse will shift out the stop bit for framing error checking.
low.
When FSK demodulation is enabled via the CB1 and CB2 pins this pin is the Data Ready output.
It denotes the end of a word. In both FSK interface modes 0 and 1, it is normally hi and goes low
for half a bit time at the end of a word. But in mode 1 if DCLK starts during DR low, the first rising
edge of the DCLK input will return DR to high. This feature allows an interrupt requested by a low
going DR to be cleared upon reading the first DATA bit.
When CAS detection is enabled via the CB1 and CB2 pins this pin is the Delayed Steering output.
It goes low to indicate that a time qualified CAS has been detected.
CAS Detection Early Steering (CMOS Output). Active high. This pin is the raw CAS detection
output. It goes high to indicate the presence of a signal meeting the CAS accept frequencies and
signal level. It is used in conjunction with the ST/GT pin and external components to time qualify
the detection to determine whether the signal is a real CAS.
with the EST pin and external components to time qualify the detection to determine whether the
signal is a real CAS.
A voltage greater than V
detected by asserting the DR/STD pin low. A voltage less than V
accept a new CAS and returns DR/STD to high.
Carrier Detect (CMOS Output). Active low.
A logic low indicates that an FSK signal is present. A time hysteresis is provided to allow for
momentary signal discontinuity. The demodulated FSK data is inhibited until carrier detect has
been activated.
Positive power supply.
Control Bit 1 (CMOS Input). Together with CB2 this pin selects the MT88E45’s functionality
between FSK demodulation, Tip/Ring CAS detection and Hybrid CAS detection.
When CB0 is high and CB1, CB2 are both low the MT88E45 is put into a power down state
consuming minimal power supply current. See Tables 1 and 2.
Control Bit 2 (CMOS Input). Together with CB1 this pin selects the MT88E45’s functionality
between FSK demodulation, Tip/Ring CAS detection and Hybrid CAS detection.
When CB0 is high and CB1, CB2 are both low the MT88E45 is put into a power down state
consuming minimal power supply current. See Tables 1 and 2.
Hybrid Gain Select (Output). This is the output of the hybrid receive connection op-amp. The op-
amp should be used to connect the MT88E45 to the telephone hybrid or speech IC receive pair.
The hybrid receive signal can be amplified or attenuated at GS2 via selection of the feedback
resistor between GS2 and IN2-. When the CPE is off-hook CAS detection of the GS2 signal
should be enabled via the CB1 and CB2 pins. See Tables 1 and 2.
Hybrid Op-amp Inverting (Input).
Hybrid Op-amp Non-Inverting (Input).
TGt
at this pin causes the MT88E45 to indicate that a CAS has been
Description
TGt
frees up the MT88E45 to
MT88E45
3

Related parts for MT88E45BN1