D4MC-1020 Omron, D4MC-1020 Datasheet - Page 2

no-image

D4MC-1020

Manufacturer Part Number
D4MC-1020
Description
LIMIT SWITCH
Manufacturer
Omron
Series
D4MCr
Datasheet

Specifications of D4MC-1020

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
10A @ 125VAC
Actuator Type
Lever, Straight
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
255gf
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
D4MC1020
Ratings
Note: 1. The above figures are for steady-state currents.
Characteristics
*1. Only for models with plungers. (Contact your OMRON representative for
*2. Less than 1 ms under a free state at the operating limits.
Structure and Nomenclature
Structure
Changing the Terminal Protective Cover
around allows the cable to be pulled out
from either the right or the left.
M4 binding head screws (with toothed
washers) are used as the terminal screws.
125 VAC
250 VAC
480 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Degree of protection
Durability
Operating speed
Operating
frequency
Rated frequency
Insulation resistance
Contact resistance
Dielectric
strength
Rated insulation voltage (Ui)
Pollution degree
(operating environment)
Protection against electric shock
PTI (tracking characteristics)
Switch category
Rated operating current (Ie)
Rated operating voltage (Ue)
Vibration
resistance
Shock
resistance
Ambient operating temperature
Ambient operating humidity
Weight
voltage
current
Inrush
Rated
information on other models.)
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The above ratings were tested under the following conditions.
constant of 7 ms max. (DC).
(1) Ambient temperature: +20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency: 20 operations/min
Resistive load
Mechanical
Electrical
Mechanical
Electrical
Between terminals of the
same polarity
Between each terminal and
non-current-carrying part
Malfunction
Destruction
Malfunction
NC
NC
NO
Non-inductive load (A)
0.25
0.5
10
10
10
10
3
6
NO
30 A max.
15 A max.
NC
2.5
1.5
0.4
0.2
Lamp load
3
3
3
3
IP67
10,000,000 operations min.
500,000 operations min.
0.05 mm/s to 0.5 m/s *1
120 operations/min
20 operations/min
50/60 Hz
100 MΩ min. (at 500 VDC)
15 mΩ max. (initial value for the built-in
switch when tested alone)
1,000 VAC, 50/60 Hz for 1 min
2,000 VAC, 50/60 Hz for 1 min
1,000 VAC
3 (IEC947-5-1)
Class II
175
D (IEC335)
10 A
250 VAC
10 to 55 Hz, 1.5-mm double amplitude *2
1,000 m/s
100 m/s
−10°C to +80°C (with no icing)
35% to 95%RH
Approx. 71 g (in case of panel mount plunger)
1.25
0.75
NO
1.5
1.5
1.5
1.5
0.4
0.2
2
min. *1 *2
Inductive load
2
NC
min.
0.05
0.03
Inductive load (A)
2.5
10
10
Pushbutton
6
6
5
Terminal
Protective
Cover
NO
terminal (COM)
0.05
0.03
NC
Motor load
1.5
Common
5
3
5
5
5
0.75
0.05
0.03
NO
Normally open
terminal (NO)
2.5
1.5
2.5
2.5
2.5
Roller
Normally closed
terminal (NC)
Case
Approved Standard Ratings
UL/CSA
A300
EN60947-5-1
CCC (GB14048.5)
Engineering Data
Electrical Durability
Mechanical Durability (D4MC-5000)
Rated voltage
10,000
10,000
5,000
2,000
1,000
7,000
5,000
3,000
1,000
500
200
100
700
500
300
100
120 VAC
240 VAC
70
50
30
10
Built-in switch
0.01 0.02
0
Applicable category and ratings
Seal rubber
AC-12 10 A/250 VAC
2
0.05 0.1
Operating temperature: +20
Operating humidity: 65
Operating frequency: 20 operations/min
125 VAC cosφ=1
4
current
125 VAC cosφ=0.4
Operating temperature: +20
Operating humidity: 65
No load
Operating frequency: 120 operations/min
Carry
10A
250 VAC cosφ=1
0.2
250 VAC cosφ=0.4
6
0.5
Contact Form
Switching Current (A)
1
Make
8
±
(COM) 1
±
5%RH
60
30
5%RH
Current (A)
2
±
±
2 ° C
2°C
10
OT (mm)
5 10
Break
12
6
3
Volt-amperes (VA)
Make
7,200
2 (NC)
4 (NO)
D4MC
Break
720
2

Related parts for D4MC-1020