BP-FRN-R-40 Cooper/Bussmann, BP-FRN-R-40 Datasheet

BP-FRN-R-40

Manufacturer Part Number
BP-FRN-R-40
Description
Manufacturer
Cooper/Bussmann
Type
Dual Elementr
Datasheet

Specifications of BP-FRN-R-40

Acting
Slow Blow
Voltage Rating (vac)
250V
Voltage Rating (vdc)
125V
Current Rating
40A
Mounting
Surface Mount
Product Depth (mm)
Not Requiredmm
Product Height (mm)
Not Requiredmm
Lead Free Status / RoHS Status
Not Compliant
Catalog Symbol: FRN-R
Current-Limiting
Dual-Element, Time-Delay – 10 seconds (minimum) at 500%
Ampere Rating: 70 to 600A
Voltage Rating:
Interrupting Rating:
Agency Information:
UL Listed, Std. 248-12, Class RK5, Guide JDDZ, File E4273
CSA Certified, C22.2 No. 248.12, Class 1422-01, File 53787
Catalog Numbers
FRN-R-70
FRN-R-75
FRN-R-80
FRN-R-85
FRN-R-90
FRN-R-100
FRN-R-110
Carton Quantity and Weight
Ampere
Ratings
70–100
101–200
201–400
401–600
*Weight per carton.
Fusetron
Dual-Element, Time-Delay Fuses
Class RK5 – 250 Volt
4-2-03
rated current
To obtain information for 0-60A, access Data Sheet: 1019
250Vac (or less)
125Vdc (70-200A)
250Vdc (201-600A)
200,000A RMS Sym.
20,000A AIC
SB03091
Carton
Qty.
5
1
1
1
®
FRN-R-125
FRN-R-150
FRN-R-175
FRN-R-200
FRN-R-225
FRN-R-250
FRN-R-300
Lbs.
0.77
1.52
1.5
3.0
Weight*
FRN-R-350
FRN-R-400
FRN-R-450
FRN-R-500
FRN-R-600
0.680
0.349
0.689
Kg.
1.4
Dimensional Data
General Information:
• Provides motor overload, ground fault and short-circuit
• Helps protect motors against burnout from overloads and
• Simplifies and improves blackout prevention (selective
• Dual-element fuses can be applied in circuits subject to
• The overload element provides protection against low level
Fuse Reducers For Class R Fuses
Equipment
Fuse Clips
*Single reducer only (pair not required).
450A to 600A
70A to 100A
110A to 200A
225A to 400A
200A
400A
600A
protection.
single phasing when sized properly.
coordination).
temporary motor overloads and surge currents to provide
both high performance short-circuit and overload
protection.
overcurrent of overloads and will hold on inrush current
which is five times greater than the ampere rating of the
fuse for a minimum of ten seconds.
CE logo denotes compliance with European Union Low Voltage Directive
Bussmann Application Engineering at 636-527-1270 for more information.
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
( 0.062)
5.88"
( 0.062)
7.13"
( 0.094)
8.63"
( 0.094)
10.38"
Desired Fuse
(Case) Size
1.06" ( 0.008)
100A
100A
200A
100A
200A
400A
1.56" ( 0.008)
2.06" ( 0.008)
2.59" ( 0.008)
Bussmann
Form No. FRN-R 70-600
Catalog Number
70-600A
(Pairs) 250V
No. 2621-R
No. 2641-R
No. 242-R
No. 2661-R
No. 2662-R
No. 2664-R*
FRN-R
Data Sheet: 1020
Page 1 of 3
®

Related parts for BP-FRN-R-40

BP-FRN-R-40 Summary of contents

Page 1

... Helps protect motors against burnout from overloads and single phasing when sized properly. • Simplifies and improves blackout prevention (selective coordination). • Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection. ...

Page 2

... Fusetron ® Dual-Element, Time-Delay Fuses Class RK5 – 250 Volt Recommended fuseblocks for Class R 250V fuses See Data Sheet 1110 4-2-03 SB03091 Time-Current Characteristic Curves–Average Melt 300 100 .01 CURRENT IN AMPERES Bussmann ® FRN-R 70-600A AMPERE RATING Form No. FRN-R 70-600 Page ...

Page 3

... Fusetron ® Dual-Element, Time-Delay Fuses Class RK5 – 250 Volt Current-Limitation Curves The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products ...

Related keywords