930222 CROPICO, 930222 Datasheet - Page 3

no-image

930222

Manufacturer Part Number
930222
Description
THERMOMETER, DIGITAL, 3001
Manufacturer
CROPICO
Datasheet

Specifications of 930222

Temperature Tester Type
Thermocouple
Thermocouple Type
B, E, J, K, N, R, S, T, D, C
Operating Temperature Range
0°C To +40°C
External Depth
110mm
External Length / Height
315mm
External Width
219mm
Lead Free Status / RoHS Status
na
THE 3000 SERIES
TEMPERATURE MEASURING INSTRUMENTS
The 3000 series scanner option provides for multi inputs of either thermocouples or Pt100 sensors. Two channel cards may be fitted each with four
input channels, which may be either thermocouples or Pt100. The flexibility of the system is such that scanner cards can be interchanged giving 10
channels for Pt100, 10 channels for thermocouples, or 4 channels thermocouples plus 4 channels Pt100 plus the two front panel inputs, which may
be either Pt100 or thermocouples. No other instrument in this price range gives the versatility and accuracy of measurement to match the 3000.
D D i i s s p p l l a a y y
LCD Graphics panel with backlight
T T e e r r m m i i n n a a l l s s
4mm safety sockets and 6 pin Lemo socket
W W o o r r k k i i n n g g T T e e m m p p e e r r a a t t u u r r e e
0°C to +40°C re. humidity 80% max. non-condensing
S S t t o o r r a a g g e e T T e e m m p p e e r r a a t t u u r r e e
-20°C to +50°C
M M a a i i n n s s S S u u p p p p l l y y
100/120/220/240 Volts +10% to 13%
47Hz to 63Hz 40VA
S S a a f f e e t t y y
EN 61010-1 EMC-EN 61236
D D i i m m e e n n s s i i o o n n s s
219mm x 315mm x 110mm (W H D) approx
1/2 19” Rack 2U high
M M a a s s s s
5.5kg approx
C C a a l l i i b b r r a a t t i i o o n n
Digital Pass code protected
B B a a t t t t e e r r y y
Sealed Lead acid battery with internal intelligent charger.
14 hours approx operation from full charge, may be used
whilst charging
Code
3000-01
3000-03
3000-04
3000-05
3000-06
3000-07
3000-A-10
3000-A-11
3000-A-12
3000-A-13
3000-A-20
3000-A22
RSL-02
Item
RS232 interface
IEEE-488 interface
Analogue output
Scanner option, input cards to be ordered separately
Scanner card for Pt100 4 channels. Scanner option 3000-05 must be installed
Scanner card for thermocouple inputs 4 channels. Scanner option 3000-05
must be installed
Calibration cable
Calibration standards for Pt100 channels, consisting of 3 standard resistors 100, 250,
and 400 ohm
Adapter box 4mm copper terminals to Lemo plug
RTD Lemo input plug
Thermocouple plug with screw terminals materials type R S B J T E K available please
specify when ordering
External thermocouple reference junction
RS232 Cable
3000 series options
Bracken Hill, South West Industrial Estate, Peterlee, County Durham, SR8 2SW United Kingdom
Tel: +44 (0) 191 586 3511 Fax: +44 (0) 191 586 0227 Email: sales@cropico.com Web: www.cropico.com
Scanner Options
I I n n p p u u t t s s
Thermocouples via 4mm sockets in copper block on 19mm
pitch, adaptor plugs available for direct thermocouple wire
connection. PRT via Lemo low thermal sockets. 3002 model has
low thermal E.M.F sockets only
A A v v e e r r a a g g e e
Automatic average and display of PRT measurements with
forward and reverse current
A A u u t t o o T T e e m m p p e e r r a a t t u u r r e e C C o o m m p p e e n n s s a a t t i i o o n n f f o o r r T T h h e e r r m m o o c c o o u u p p l l e e s s
Automatic Internal- Automatically references measurement to
temperature of 20°C or other user defined temperature.
User coefficients may be used
Automatic External- External Pt100 sensor temperature manual
value can also be used
H H i i / / L L o o w w L L i i m m i i t t s s
Limit values can be set over entire measurement range
I I n n t t e e r r f f a a c c e e s s
Interface cards are available as option, only one card may be fitted.
RS232: To specification ANSI/EIA/TIA/-232-E-1991
IEEE-488: Conforms to ANSI-IEEE Std 488, 1-1987 and performs
the following functions: SH1, AH1,T5,TEO, L3, LEO, SR1, RL1,
PPO, DT1, CO, E2. Interface may be set to ‘talk only’ mode to
permit stand alone printer output
Scanner Option: 2 additional input cards may be fitted, each card
has 4 measurement channels. Measurement and scan sequences
may be configured from the front panel. Full accuracy is maintained
T T h h e e r r m m o o c c o o u u p p l l e e s s
The above readings apply to values with the reference junction
switched off. Reference junction uncertainty when used in
automatic mode is better than 0.1°C at 20 °C with a deviation of
not more than 0.01 °C/°C over the range 0 to 100 °C. RTD types
linearised to ITS-90 conforms to EN 60751. Thermocouples are
not available on 3002 model
3000
I
I
I
I
I
I
I
I
I
I
I
I
I
3001
I
I
I
I
I
I
I
I
I
I
I
I
I
3002
I
I
I
I
I
I
I
I
I
I
I
I
I