Specifications of FLK-TI50FT-20

Temperature Measuring Range
-20° To 350°C (-4° To 662°F)
Temperature Tester Type
Thermal Imager
Accuracy %
2%
Lead Free Status / RoHS Status
na
*Standard 20 mm Germanium lens
General specifications
Ordering information
3 Fluke Corporation
Optical lenses (continued)
10.5 mm wide angle lens
Image and data storage
Storage medium
File formats supported
Interface and software
Interface
Software
Laser
Classification
Laser targeting
Controls and adjustments
Set-up controls
Image controls
On-screen indicators
Power
Battery type
Battery operating time
Battery charging
Continuous ac operation
Power saving
Environmental and mechanical design
Operating temperature
Storage temperature
Relative humidity
Water and dust resistant
Weight (including batteries)
Camera size (H x W x D)
Other
Warranty
Included with product
Heavy duty carrying case, 2 rechargeable
battery packs, battery charger, ac adapter
(for Ti45FT and Ti55FT only), video cable,
512 MB compact flash card, compact flash
card reader and USB cable, PCMCIA
compact flash card reader, neck strap,
printed getting started guide, SmartView
reporting and analysis, software on CD,
complete user manual on CD
FLK-Ti40FT-20
FLK-Ti45FT-20
FLK-Ti50FT-20
FLK-Ti55FT-20
Ti5XFT and Ti4XFT Thermal Imagers with IR-Fusion
IR FlexCam Thermal Imager with IR-Fusion
IR FlexCam Thermal Imager with IR-Fusion
IR FlexCam Thermal Imager with IR-Fusion
IR FlexCam Thermal Imager with IR-Fusion
AC adapter 110/220 V ac,
Fluke Ti55FT
50/60 Hz
Spatial resolution (IFOV): 2.45 mrad
Date/time, temperature units C/F, language, scale, LCD intensity (high/normal/low)
14 bit measurement data included. Exportable Images: bmp, gif, jpg, png, tiff;
Battery status, target emissivity, background temperature and realtime clock
Compact flash card stores over 1000 IR images (512 MB card standard)
Laser dot visible on screen when blending thermal and visible image
Li-Ion smart battery, rechargeable, field-replaceable (two included)
SmartView; Full analysis and reporting software included
Data formats: comma separated (csv), tab separated (txt).
162 mm x 262 mm x 101 mm (6.5 in x 10.5 in x 4.0 in)
Operating and storage 10 % to 95 %, non-condensing
Automatic shutdown and sleep modes (user specified)
Two bay intelligent charger powered via ac outlet
Field of view (FOV): 42° horizontal x 32° vertical
Two hours continuous operation (per battery)
Level, span, auto adjust (continuous/manual)
Fluke Ti50FT
Compact flash card reader included
Min focus distance: 0.3 m (0.98 ft)
-40 °C to +70 °C (-40 °F to 158 °F)
-10 °C to +50 °C (14 °F to 122 °F)
High precision Germanium lens
1.95 kg (4.3 lb)
Two-years
Class II
IP54
AC adapter 110/220 V ac,
Fluke Ti45FT
50/60 Hz
Spatial resolution (IFOV): 4.9 mrad
Fluke. Keeping your world
Fluke Corporation
PO Box 9090, Everett, WA U.S.A. 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2007 Fluke Corporation. All rights reserved.
Specifications subject to change without notice.
Printed in U.S.A. 8/2007 2674273 D-EN-N Rev C
up and running.
Fluke Ti40FT
®