THERMAL IMAGER, -20°C TO 350°C

FLK-TI50FT-10/20

Manufacturer Part Number
FLK-TI50FT-10/20
Description
THERMAL IMAGER, -20°C TO 350°C
Manufacturer
Fluke
Datasheet

Specifications of FLK-TI50FT-10/20

Temperature Measuring Range
-20°C To 350°C
Temperature Tester Type
Thermal Imager
Accuracy %
2%
Operating Temperature Range
-10°C To +50°C
Lead Free Status / RoHS Status
na
Detailed specifications
*Standard 20 mm Germanium lens
Detailed Specifications
2 Fluke Corporation
Imaging performance
Field of view (FOV)*
Spatial resolution (IFOV)*
Min focus distance*
Thermal sensitivity (NETD)
Detector data acquisition/image
frequency
Focus
IR digital zoom
Detector type
Spectral band
Digital image enhancement
On camera operating modes
Visible light camera
Visible light digital zoom
Temperature measurement
Calibrated temperature range
Accuracy
Measurement modes
Emissivity correction
Image presentation
Digital display
LCD backlight
Video output
Palettes
Optical lenses
54 mm telephoto lens
10.5 mm wide angle lens
Ti55FT and Ti50FT Thermal Imagers with IR-Fusion
-20 °C to 600 °C (-4 °F to 1112 °F)
in three ranges
Range one =-20 °C to
100 °C (-4 °F to 212 °F)
Range two = -20 °C to
350 °C (32 °F to 662 °F)
Range three = 250 °C to 600 °C
(482 °F to 1112 °F)
Centerpoint, center box (area min/max, average),
moveable spots/boxes, user defined field/text
annotations, automatic hot and cold point
detection, visible color alarm above and below
320 x 240 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer
≤ 0.05 °C at 30 °C (50 mK)
Grayscale, grayscale inverted, blue red, high contrast, hot metal,
Fluke Ti55FT
13 cm (5 in) diagonal large high-resolution digital display
2x, 4x, 8x
2x, 4x
SmartFocus; one finger continuous focus (manual)
Field of view (FOV): 42° horizontal x 32° vertical
RS170 EIA/NTSC or CCIR/PAL composite video
Field of view (FOV): 9° horizontal x 6° vertical
Full thermal, full visual light or merged
± 2 °C or 2 % (whichever is greater)
Spatial resolution (IFOV): 0.47 mrad
Spatial resolution (IFOV): 2.45 mrad
Min focus distance: 0.3 m (0.98 ft)
Min focus distance: 0.6 m (1.97 ft)
ironbow, amber, amber inverted
High precision Germanium lens
High precision Germanium lens
Automatic full time enhanced
1280 x 1024 pixels, full color
23° horizontal x 17° vertical
Sunlight readable color LCD
0.1 to 1.0 (0.01 increments)
thermal-visual images.
Picture-in-Picture
0.15 m (5.9 in)
8 µm to 14 µm
60 Hz/60 Hz
1.30 mrad
-20 °C to 350 °C (-4 °F
to 662 °F) in two ranges
Range one = -20 °C to
100 °C (-4 °F to 212 °F)
Range two = -20 °C to
350 °C (32 °F to 662 °F)
Centerpoint, center box
(area min/max, average)
≤ 0.07 °C at 30 °C (70 mK)
Fluke Ti50FT
2x
2x