FLK-TIS 9HZ Fluke, FLK-TIS 9HZ Datasheet - Page 3

THERMAL IMAGING SCANNER, -20°C TO +100°C

FLK-TIS 9HZ

Manufacturer Part Number
FLK-TIS 9HZ
Description
THERMAL IMAGING SCANNER, -20°C TO +100°C
Manufacturer
Fluke
Type
Thermal Imagerr
Datasheet

Specifications of FLK-TIS 9HZ

Temperature Measuring Range
-20°C To +100°C
Temperature Tester Type
Thermal Imager
Accuracy %
5%
Operating Temperature Range
-10°C To +50°C
Batteries
Charge Time: 2.5 hours to full charge
Battery Life
Three to four hours continuous use (assumes 50% brightness of LCD)
Detector Type
120 × 120 Focal Plane Array, uncooled microbolometer
Dimensions
10.5"(H) × 5.0"(W) × 6.0"(L)
Display
LCD, 9.3 cm (3.7 in.)
Frequency
Image Capture: 9 Hz Refresh Rate
Memory
Review: Sequential image navigation and review
Sensitivity
Thermal: ≤0.1°C at 30°C target temp. (100 mK)
Shock Resistance
25 g, IEC 68-2-29
Software
SmartView® full analysis and reporting software included
Temperature Accuracy
±5°C or 5% (at 25°C nominal, whichever is greater)
Temperature Range
Measuring Range: –20°C to +100°C
Vibration
0.03 g2/Hz (3.8 grms), IEC 68-2-6
Warranty
Two Years
Weight
(Battery Included): 2.6 Lbs.
Lead Free Status / RoHS Status
na
Ordering information
Included: TiS Thermal Imaging Scanner with standard infrared lens; ac power supply/battery
charger (including mains adapters); SD memory card; multi-format USB memory card reader for
downloading images into your computer; SmartView
life; rugged, hard carrying case; soft transport bag; adjustable hand strap; users manual on CD;
warranty registration card; interactive training DVD.
FLK-TiS 9Hz Thermal Imaging Scanner
Optional accessories
TI-CAR-CHARGER Thermal Imager Vehicle Charger
TI-VISOR Thermal Imager Visor
BOOK-ITP Introduction to Thermography Principles Book
TI-TRIPOD Tripod Mounting Base Accessory
®
software with free software upgrades for
Key benefits of Fluke thermal imagers
in building inspections:
• Expand your business offering with infrared inspections
• Differentiate your service from competition
• Find hidden problems
• Identify issues faster
• Identify areas for customers to reduce energy usage
• Document and validate your work
• Reduce liability
• Increase safety
Applications for building inspections
Residential:
• Air infiltration (energy usage/comfort)
• Missing, improperly installed or settled insulation
• Roof leak inspection
• Duct leaks
• HVAC testing
• In floor heating
• Dryer vents
• Residential electrical
• Moisture intrusion and condensation issues
Commercial:
• Roof leak inspection
• Commercial HVAC
• Moisture detection
• Steam traps
• Electrical inspections
• Electrical motors
• Pumps and hydraulics
• Commercial energy loss (building envelope inspection)
• Plumbing
Fluke. Not just infrared.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2010 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 6/2010 3804542A D-EN-N
Modification of this document is not permitted
without written permission from Fluke Corporation.
Infrared you can use.