HC2-S

Manufacturer Part Number
HC2-S
Description
HUMIDITY PROBE, PRECISION
Manufacturer
ROTRONIC
Datasheet

Specifications of HC2-S

Humidity Range
0% To 100%
Resolution (°c)
0.01K
External Height
92mm
Lead Free Status / RoHS Status
na

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HC2-SF-K
Manufacturer:
Panasonic Electric Works
Quantity:
135
Part Number:
HC2-SFD-K
Manufacturer:
AMPHENOL
Quantity:
136
Part Number:
HC2-SFD-S
Manufacturer:
Panasonic Electric Works
Quantity:
135
tech n ic al i n fo r m atio n.
Factory Adjustment.
Three different adjustment profiles are available from the factory; this
means that measurement accuracy can be matched to the application
need. The custom adjustment profile consists of 20 Humidity values
at 3 Temperatures to ensure optimum performance over a required
working range. Calibration data is stored within the probe and can be
retrieved later for audit purposes.
Probe Output Signal.
When connected to a PC the HygroClip2 probes can be rescaled with
different ranges to suit the application need. It is also possible to
assign the internally calculated dew or frost point value to one of these
outputs; thus converting the HygroClip2 into a dew point probe.
Sensor Diagnostics.
The intelligence of AirChip3000 technology enables advanced sensor
diagnostics. Should the RH sensor deviate from factory defined
parameters (for example because of chemical contamination)
measurement values can be automatically compensated and a digital
alarm triggered. The HygroClip2 probe can also be programmed to
generate an alarm in the form of pre-defined analog output signals
in the event of a problem with either the RH or temperature sensor.
The user has full control over these features using ROTRONIC HW4
software.
Data Logging and Alarm Generation.
Up to 2,000 measurement values can be stored in the HygroClip2
probe; the user is able to configure the measurement interval, set
alarm limits, scale the output signal and download data using optional
ROTRONIC HW4 software. The HygroClip2 probe can be programmed
with set limits to generate an alarm which is available when the probe
is communicating with a PC or compatible ROTRONIC device. Thus,
the HygroClip2 can be integrated in any application.
temperature and humidity measurements. You can find detailed information about our probes
at www.rotronic-humidity.com. We would also be happy to advise you in person or on the phone.
ROTRONIC AG, Grindelstrasse 6, CH - 8303 Bassersdorf, Tel. +41 44 838 11 11, Fax +41 44 836 44 24, www.rotronic.ch
ROTRONIC Instruments (UK) Ltd, Crompton Fields, Crompton Way, Crawley, West Sussex, RH10 9EE, UK, Phone +44 (0)1293 571000, Fax +44 (0)1293 571008, www.rotronic.co.uk
ROTRONIC Instrument Corp, 160 E. Main Street, Huntington, NY 11743, USA , Phone, +1 631 427-3898, Fax, +1 631 427-3902, www.rotronic-usa.com
Change over now to the HygroClip2 probes with integrated AirChip3000 technology for your
92 mm
85 mm
Humidity sensor
Temperature sensor
Accuracy with Standard
adjustment profile
Accuracy with High Precision
adjustment profile
Accuracy with Custom
adjustment profile
Resolution, AirChip3000
Long-term stability
Humidity response time t 63
Measurement range
Electronics operating range
Analog output signals
(standard, user scalable)
PC interface UART
(standard)
Sensor diagnosis function
Alarm function
Audit Trail & Electronic Records
Power supply & consumption
Housing/probe material
Filter
Standards
Electrical connections:
ROTRONIC Hygromer
Pt100 1/3 Class B
at 23 °C and 10, 35, 80 %rh
± 0.8%rh / ± 0.1 K
at 23 °C and 10, 20, 30, 40, 50, 60,
70, 80, 90 % rh ± 0.5%rh/ 0.1 K
at 3 freely selectable temperatures
between -10 and 70 °C and 20 freely
selectable %rh values (10…90 %rh)
± 0.5 %rh / 0.1 K
Typically 0.02 %rh, 0.01 K
< 1 %rh, 0.1 °C / year
3...12 seconds
(depending on probe type)
0…100 %rh, -100…200 °C
(depending on probe type)
-50…100 °C and 0…100 %rh
0…1 V = 0...100 %rh
0…1 V = -40...60 °C
with ROTRONIC interface cable
HW4 compliant
Yes (programmable, factory default = off)
Yes, analog & digital, programmable
FDA 21CFR Part 11 and GAMP compliant
3.2…5 VDC ±0 % / typically 4 mA
Polycarbonate or stainless steel
(depends on probe type)
Polyethylene insert, polycarbonate cage
CE-compliant 2007/108/EG
V+
GND (digital and power)
RXD (UART)
TXD (UART)
Analog signal, humidity
(0...100 %rh = 0...1 V)
Analog signal °C
(-40...60 °C = 0...1 V)
AGND (analog ground)
®
IN-1