608-H2 TESTO, 608-H2 Datasheet - Page 23

HYGROMETER

608-H2

Manufacturer Part Number
608-H2
Description
HYGROMETER
Manufacturer
TESTO
Datasheet

Specifications of 608-H2

Humidity Range
2% To 98%
Resolution (°c)
0.1°C
External Height
120mm
External Width
89mm
External Depth
40mm
Svhc
No SVHC (15-Dec-2010)
Accuracy %
2%
Battery Size Code
9V
Operating Temperature Max
70°C
Connection cable for unlimited Pt100 stationary probes with screw terminals (4-wire technology), max. cable length: 20 m
Stationary probe with stainless steel sleeve, TC
Type K
Magnetic probe, adhesive force approx. 20 N, with
magnets, for measurements on metal surfaces, TC
Type K
Magnetic probe, adhesive force approx. 10 N, with
magnets, for higher temp., for measurements on
metal surfaces, TC Type K
Pipe wrap probe for pipe diameter 5 to 65 mm, with
exchangeable measuring head. Meas. range short-
term to +280°C, TC Type K
Pipe wrap probe with Velcro strip, for temperature
measurement on pipes with diameter up to max. 120
mm, Tmax +120°C, TC Type K
Thermocouple with TC adapter, flexible, 800mm
long, fibre glass, TC Type K
Thermocouple with TC adapter, flexible, 1500mm
long, fibre glass, TC Type K
Thermocouple with TC adapter, flexible, 1500mm
long, PTFE, TC Type K
Immersion tip, flexible, TC Type K
Immersion measurement tip, flexible, for
measurements in air/exhaust gases (not suitable
for measurements in smelters), TC Type K
Stub probe, IP 54
Stationary probe with aluminium sleeve, IP 65
Accurate imm./pen. probe, 6m cable, IP 67
Accurate immersion/penetration probe, cable: 1.5
m long, IP 67
Wall surface temperature probe, e.g. to prove
damage in building material
Stainless steel NTC food probe (IP65) with PUR
cable
Pipe wrap probe with Velcro for pipe diameter to
max. 75 mm, Tmax. +75°C, NTC
* Probe tested to EN 12830 for suitability in the transport and storage sectors
testo Saveris
Pt100
TC
NTC
%RH
Robust, Pt100 stainless steel food probe (IP65)
Robust, waterproof Pt100
immersion/penetration probe
Robust air probe, T/C Type K
Waterproof NTC immersion/penetration probe
Humidity / Temperature Probe 12mm
Humidity / Temperature Probe 4 mm
The specified accuracy class of the Saveris radio and Ethernet probe is achieved using these external probes.
Additional information at
Plug-in probes
Plug-in probes
Plug-in probes
Plug-in probes
*According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
Accessories: External temperature probes
Illustration
Conn.: Fixed cable
Fixed cable
Illustration
Conn.: Fixed cable 1.9 m
Conn.: Fixed cable 1.2 m
Fixed cable
Conn.: Fixed cable 1.6 m
Conn.: Fixed cable 1.5 m
Illustration
Conn.: Fixed cable; Cable/length: 2.4 m
Conn.: Fixed cable; Cable/length: 6 m
Conn.: Fixed cable; Cable/length: 1.5 m
Conn.: Fixed cable; Cable/length: 1.6 m
Conn.: Fixed cable
Conn.: Fixed cable; Cable/length: 1.5 m
Illustration
www.testo.com
www.testo.com
Ø 3 mm
75 mm
35 mm
300 mm
Ø 1.5 mm
Ø 1.5 mm
Ø 1.5 mm
1500 mm
1500 mm
395 mm
800 mm
Ø 6 mm
Conn.: Fixed cable 1.2 m
Ø 3 mm
Ø 3 mm
40 mm
40 mm
40 mm
Conn.: Fixed cable; Cable/length: 3 m
Ø 20 mm
125 mm
Ø 4 mm
Ø 3 mm
35 mm
Ø 1.5 mm
115 mm
500 mm
125 mm
115 mm
Ø 4 mm
Ø 6 mm
Ø 4 mm
Ø 5 mm
40 mm
Ø 12 mm
114 mm
Ø 5 mm
Ø 4 mm
1000 mm
Ø 21 mm
Ø 3.7 mm
Ø 3 mm
15 mm
50 mm
Ø 4 mm
Ø 3 mm
Ø 3 mm
50 mm
Ø 3 mm
15 mm
2) Long-term measurement range +125°C, short-term +150°C or +140°C (2 minutes)
Meas. range
-50 to +400 °C
-50 to +400 °C
Meas. range
-50 to +205 °C
-60 to +400 °C
-50 to +170 °C
-50 to +400 °C
-60 to +130 °C
-50 to +120 °C
-50 to +400 °C
-50 to +400 °C
-50 to +250 °C
-200 to +1000
°C
-200 to
+1300 °C
Meas. range
-20 to +70 °C
-30 to +90 °C
-35 to +80 °C
-35 to +80 °C
-50 to +80 °C
-50 to +150 °C
-50 to +150 °C
-50 to +70 °C
Meas. range
-20 to +70 °C, 0
to +100 %RH
0 to +40 °C, 0 to
+100 %RH
2)
Class A (-50 to +300 °C),
Class B (remaining range)
Accuracy
Class A (-50 to +300 °C),
Class B (remaining range)
Accuracy
Class 2*
Class 2*
Class 2*
Class 2*
Class 2*
Class 1*
Class 2*
Class 2*
Class 2*
Class 1*
Class 1*
Accuracy
±0.2 °C (-20 to +40 °C)
±0.4 °C (+40.1 to +70 °C)
±0.2 °C (0 to +70 °C)
±0.5 °C (remaining range)
±0.2 °C (-25 to +74.9 °C)
±0.4 °C (remaining range)
±0.2 °C (-25 to +74.9 °C)
±0.4 °C (remaining range)
±0.2 °C (0 to +70 °C)
±0.5% of mv (+100 to +150 °C)
±0.2 °C (-25 to +74.9 °C)
±0.4 °C (remaining range)
±0.5% of mv (+100 to +150 °C)
±0.2 °C (-25 to +74.9 °C)
±0.4 °C (remaining range)
±0.2 °C (-25 to +70 °C)
±0.4 °C (-50 to -25.1 °C)
Accuracy
±0,3 °C, ±2 %RH (2 to 98
%RH)
±0,3 °C, ±2 %RH (2 to 98
%RH)
t99
10 s
12 s
t99
20 s
25 s
150
s
5 s
90 s
5 s
5 s
5 s
5 s
4 s
t99
15 s
190
s
5 s
5 s
20 s
8 s
10 s
Part no.
0609 2272
0609 1273
0554 0213
Part no.
0628 7533
0602 1793
0602 4792
0602 4892
0602 4592
0628 0020
0602 0644
0602 0645
0602 0646
0602 5792
0602 5693
Part no.
0628 7510
0628 7503*
0610 1725*
0628 0006*
0628 7507
0613 2211*
0613 1212
0613 4611
Part no.
0572 6172
0572 6174
23