CM-3 3M, CM-3 Datasheet - Page 3

Gas Detector

CM-3

Manufacturer Part Number
CM-3
Description
Gas Detector
Manufacturer
3M
Datasheet

Specifications of CM-3

Gas Detector Type
Single Gas
No. Of Sensors
1
For Use With
Ventilation Control And HVAC/bldg. Automation Systems
Lead Free Status / RoHS Status
na

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CM-322522-2R2K
Manufacturer:
Bourns
Quantity:
450
Part Number:
CM-322522-470K
Manufacturer:
Bourns
Quantity:
1 050
Part Number:
CM-322522-4R7K
Manufacturer:
Bourns
Quantity:
3 070
Part Number:
CM-322522-680K
Manufacturer:
Bourns
Quantity:
1 471
Part Number:
CM-322522-R56K
Manufacturer:
MURATA
Quantity:
611
Carbon Monoxide Detectors
Nitrogen Dioxide
For Homes, Offices, Warehouses, Commercial Buildings, Enclosed Parking Garages, Vehicle Maintenance Facilities
CM-1B
CO alarm, detector and controller for
use in commercial applications.
• Digital meter (0-250 ppm)
• 12-24 VAC or VDC operation
• Dual relays: fan (SPDT) and
• 85 dBA buzzer
• Fan relay actuation:
• Alarm relay actuation:
• Optional transformer for
CM-E1
UL listed CO detector for use with fire
and security alarm systems.
• UL 2075 listed
• Flush or surface mount
• 9-32 VAC or VDC operation
• SPDT alarm relay
• LED status display
• 85 dBA buzzer
• SPDT trouble re lay
• Designed to meet the NFPA
For Parking Garages, Warehouses,
Maintenance Facilities, Ice Skating Arenas
ND-1
Detector and controller for detection
and ventilation of nitrogen dioxide
from diesel exhaust fumes.
• Digital meter (0-9ppm)
• 12-24 VAC or VDC operation
• Adjustable relay set points
• NEMA 1 enclosure
• SPDT fan relay
• N.O. alarm relay
alarm (N.O.)
35 ppm CO after 5 min.
100 ppm CO after 30 min.
200 ppm CO after 10 min.
120V operation
720-2009 standard for CO sensor
functionality and sensitivity testing
(sold separately)
®
ND-2
Detector and controller for detection
and ventilation of nitrogen dioxide
from diesel exhaust fumes.
• Digital meter (0-9ppm)
• 12-24 VAC or VDC operation
• Adjustable relay set point
• NEMA 1 enclosure
• SPDT fan relay
• 4-20mA output (0-6ppm)
• Compatible with DVP-120
CM-2B
Analog CO transducer with solid state
sensor for use with HVAC/Building
Automation Systems.
• Digital meter (0-250ppm)
• 24 VAC or VDC operation
• 4-20mA output
• NEMA 1 enclosure
• Compatible to DVP-120
CM-21A
CO detector and ventilation controller
for use in commercial applications.
• Status LED’s
• 12-24 VAC or VDC operation
• Dual relays: fan (SPDT) and alarm
• Fan relay actuation: Selectable at 25
• Alarm relay actuation:
• Mounts in 4 x 4 box
(N.O.)
ppm, 35 ppm (default), 50 ppm or
100 ppm CO within 5 min.
Selectable at 100 ppm CO within 3
hours or 200 ppm CO within 10 min.
CM-3
Analog CO transducer with
electrochemical sensor for use with
HVAC/Building Automation Systems.
• Digital meter (0-250ppm)
• 12-24V operation
• 4-20mA output
• NEMA 1 enclosure
• Compatible to DVP-120
• 5 Amp SPDT adjustable fan
CM-4
Analog CO transducer for use with
SS103 Controllers or DVP-120.
• Mounts on 4 x 4 box
• 0 to 250 ppm CO range
• Analog output 1-2.9V and 4-20mA
• Status LED’s
• 12-24 VDC or VAC operations
control relay
For Bathrooms, Conference Rooms, Restaurants, Lounges
AQC-12
Hydrocarbon detector and
ventilation controller, stand-alone or
for use with systems.
• SPDT alarm relay
• Adjustable time delay and sensitiv-
• Detects cigarette smoke, VOCs
• 120 VAC operations
Air Quality Controllers
ity settings
and many other gases
CM-15 / CM-15A
UL listed CO detectors for use with fire
and security alarm systems.
• UL 2075 listed
• Flush or surface mount
• 12-24 VAC or VDC operation
• SPDT alarm relay
• LED status display
• 85 dBA buzzer (CM-15A)
• N.C. trouble relay
• MEA Approved
CS102A
Analog CO transducer with
electrochemical sensor for use with
SS103 controllers.
• Mounts on 4x4 box
• 0 to 250 ppm CO range
• Analog output 1-2.9V
• Status LED’s
AQC-21
Hydrocarbon detector and
ventilation controller, stand-alone
or for use with systems.
• SPDT alarm relay
• Adjustable time delay and
• Detects cigarette smoke, VOCs
• 12-24 VAC or VDC operation
sensitivity settings
and many other gases.