I5S Fluke, I5S Datasheet - Page 7

AC Current Clamp

I5S

Manufacturer Part Number
I5S
Description
AC Current Clamp
Manufacturer
Fluke
Datasheet

Specifications of I5S

Accuracy
10mA To 1A 1% +/-5mA
External Width
1.7"
Bandwidth
5kHz
External Depth
4.6"
Cable Length
2.5m
Current Measuring Range
10mA To 5A
External Height
0.9"
Connector Type A
BNC Adapter
Lead Length
2.5m
Connector Type
BNC
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Measurement modes
Accuracy, resolution and range
7 Fluke Corporation Fluke 430 Series Three-Phase Power Quality Analyzers
Scope
Volts/Amps/Hertz
Dips and swells
Harmonics dc, 1 to 50
Power and energy
Flicker
Unbalance
Transients
Inrush currents
Mains signaling
Logger
System monitor
Volt/Amps/Hertz
Vrms (ac+dc)
Vpk
Voltage Crest Factor (CF)
Arms (ac+dc)
Apk using 1 mV/A scaling
A Crest Factor (CF)
Hz
Dips and swells
Vrms½ (ac+dc)
Arms½ (ac+dc)
Threshold levels
Duration
5
4
Fluke 435 @ 50 Hz nominal
Fluke 435 @ 60 Hz nominal
Fluke 434 @ 50 Hz nominal
Fluke 434 @ 60 Hz nominal
Fluke 435 with i430Flex
Fluke 435 with i430Flex
4
Fluke 434 with i400s
Fluke 434 with i400s
Fluke 435
Fluke 434
Fluke 435
Fluke 434
Fluke 435
Fluke 434
Fluke 435
Fluke 434
Measurement range
1 Vrms to 600 Vrms
600 Vrms to 1000 Vrms
1 Vrms to 1000 Vrms
1 Vpk to 1400 Vpk
1.0 to > 2.8
0 kArms to 20.00 kArms
0 kArms to 20.00 kArms
0 Arms to 40/400 Arms
30 Arms to 3000 Arms
0 Apk to 5500 Apk
1 to 10
42.500 Hz to 57.500 Hz
51.000 Hz to 69.000 Hz
42.50 Hz to 57.50 Hz
51.00 Hz to 69.00 Hz
0.0 % to 200 % of nominal voltage
0.0 % to 200 % of nominal voltage
0 Arms to 20,000 Arms
0 Arms to 20,000 Arms
0 Arms to 400 Arms
30 Arms to 3000 Arms
Programmable thresholds in percent of nominal voltage
Event detection based upon ½ cycle rms voltages
Captures dips, swells, interruptions and rapid voltage changes
hhh,mm,ss,mmm
Vrms, Arms, Vcursor, Acursor, Vfund, Afund, Hz, V phase angles, A phase angles
Vrms, Vpk, V Crest Factor, Arms, Apk, A Crest Factor, Hz
Vrms ½, Arms ½
Captures up to 1000 events with date, time, duration, magnitude and phase identification with
programmable thresholds
Harmonic Volts, THD Volt, Harmonic Amps, THD Amps, K Amps, Harmonic Watts, THD Watts, K Watts, Interharmonic
Volts
Watts, VA, VAR, Power factor, Cos j/DPF, Arms, Vrms, kWh, kVAh, kVARh, peak demand interval using trend,
KYZ revenue meter verification via optional input.
Pst(
Vneg, Vzero, Aneg, Azero, Vfund, Afund, Hz, V phase angles, A phase angles
Vrms, Arms, Vcursor, Acursor
Inrush Current, Inrush duration, Arms ½, Vrms ½
Relative signaling voltage and absolute signaling voltage averaged over three seconds for two selectable frequencies
Measures and records up to 100 parameters on all 4 phases simultaneously with selecable averaging time
Captures up to 10000 events with date, time, duration, magnitude and phase identification with programmable
thresholds
Vrms, Arms, Harmonic Volts, THD Volts, Plt, Vrms ½, Arms ½, Vneg, Hz, dips and swells, unbalance
All parameters are measured simultaneously in accordance with EN50160
Using Flagging to indicate unreliable readings according IEC61000-4-30
1min
4
, Interharmonic Amps
), Pst, Plt, PF5, Vrms ½, Arms ½, Dc, Dmax, TD
1
1
1
1
4
(relative to fundamental or to total rms)
Resolution
0.01 Vrms
0.01 Vrms
0.1 Vrms
1 V
0.01
0,001 Arms to 10 Arms
0,001 Arms to 10 Arms
0.1 and 1 Arms
1 Arms
1 A
0.01
0.001 Hz
0.001 Hz
0.01 Hz
0.01 Hz
0.1 Vrms
0.1 Vrms
0,001 Arms to 10 Arms
0,001 Arms to 10 Arms
0.1 Arms and 1 Arms
1 Arms
Half cycle
1
1
Accuracy
± 0.1 % of nominal voltage
± 0.1 %
± 0.5 % of nominal voltage
5 % of nominal voltage
± 5 %
± 0.5 % ± 5 counts
± 1 % ± 5 counts
± 1 % ± 5 counts
± 0.5 % ± 20 counts
± 5 %
± 5 %
± 0.01 Hz
± 0.01 Hz
± 0.01 Hz
± 0.01 Hz
± 0.2 % of nominal voltage ± 1 % of
nominal voltage
± 1 % ± 10 counts
± 2 % ± 10 counts
± 2 % ± 10 counts
± 1 % ± 20 counts
One cycle
3
3
3
3
3
3
3
3