PMT211A PMK, PMT211A Datasheet - Page 2

PASSIVE PROBE, 250MHZ 10:1

PMT211A

Manufacturer Part Number
PMT211A
Description
PASSIVE PROBE, 250MHZ 10:1
Manufacturer
PMK
Datasheet

Specifications of PMT211A

Test Probe Type
Oscilloscope
Accuracy
± 2%
Approval Category
300V CATII
Attenuation
10
Capacitance Max
12.5pF
Frequency Measuring Range
250 MHz
Resistanc
RoHS Compliant
For Use With
Oscilloscopes
PMT 211A
Datasheet
This datasheet supersedes all previously published material. Specifications that are defined typical
are not guaranteed and are published as general information to the user. The instrument should
have warmed up for at least 20 minutes and the environmental conditions must not exceed the spe-
cified limits of the probe. Note that specifications are subject to change without notice.
Electrical specifications
Attenuation ratio
Voltage coefficient
Probe bandwidth
Probe risetime
Maximum rated input voltage
Measurement category I:
Measurement category II:
Pollution degree
Voltage derating
(1) Connected to oscilloscope with an input impedance of 1 MΩ ± 1 %.
(2) at 15 pF input capacitance of the measuring instrument.
400
300
200
100
0
0,1
Typical voltage derating PMT211A
(1)
Measurement category I
1
Frequency [MHz]
(2)
10
100
10:1
0.0025 % / V
250 MHz
1.4 nsec
400 V rms, 1250 V transient overvoltage
300 V rms, CAT II
2
1000
Note that the max. input voltage
rating of the probe decreases as
the frequency of the applied signal
increases.
© 2007 PMK GmbH
± 2 % at DC
(typical)
(-3 dB)
(10 % – 90 %)
(typical)
2