HZ51 HAMEG, HZ51 Datasheet - Page 2

no-image

HZ51

Manufacturer Part Number
HZ51
Description
PROBE, 10X, 150MHZ
Manufacturer
HAMEG
Datasheet

Specifications of HZ51

Test Probe Type
Oscilloscope
Svhc
No SVHC (15-Dec-2010)
For Use With
Oscilloscope HM203-6
Channels:
Operating Modes:
X in XY-Mode:
Invert:
Bandwidth (-3 dB):
Rise time:
Overshoot:
Bandwith limiting (selectable): about 20 MHz (5 mV/ cm - 20 V/ cm)
Deflection Coefficients(CH1,2):14 calibrated steps
Inputs CH 1, 2:
Impedance:
Coupling:
Max. Input Voltage:
Y Delay Line (analog):
Measuring Circuits:
Analog mode only:
Auxiliary input:
Analog and Digital Mode
Automatic (Peak to Peak):
Normal (without peak):
Operating modes:
Slope:
Sources:
Coupling:
Video:
Indicator for trigger action: LED
External Trigger via:
Coupling:
Max. input voltage:
Digital mode
Pre/Post Trigger:
Analog mode
2nd Trigger
Analog mode
Accessories supplied: Line cord, Operating manual, 2 Probes 10:1 with attenuation ID, Windows Software for control and data transfer
Optional accessories: HO720 Dual-Interface RS-232/USB, HO730 Dual-Interface Ethernet/USB, HO740 Interface IEEE-488 (GPIB), HZ70 Opto-Interface (with optical
fiber cable)
Vertical Deflection
Analog:
Digital:
Analog:
Digital:
1 mV – 2 mV/cm (10 MHz) ± 5 % (0 - 10 MHz (-3 dB))
5 mV – 20 V/cm
variable (uncalibrated):
Function (selectable):
Coupling:
Max. input voltage:
Triggering
Min. signal height:
Frequency range:
Level control range:
Min. signal height:
Frequency range:
Level control range:
Standards:
Field:
Line:
Source:
Min. signal height:
Frequency range:
Coupling:
Level control range:
Horizontal Deflection
Operating modes:
Time base A:
Time base B:
X Magnification x10:
Variable time base A/B: cont. 1:2.5
Hold Off time:
Bandwidth X-Amplifier: 0 - 3 MHz (-3 dB)
Accuracy A and B:
Accuracy:
Valid at 23 °C after a 30 minute warm-up period
100 MHz CombiScope
2
2
CH 1 or CH 2 separate, DUAL (CH 1 and
CH 2 alternate or chopped), Addition
CH 1 or CH 2 separate, DUAL (CH 1 and
CH 2), Addition
CH 1
CH 1, CH 2
2 x 0 - 100 MHz
‹ 3.5 ns
max. 1 %
± 3 % (1-2-5 sequence)
› 2.5 :1 to › 50 V/cm
1 MΩ II 15 pF
DC, AC, GND (ground)
400 V (DC + peak AC)
70 ns
Measuring Category I
Extern Trigger, Z (unblank)
AC, DC
100 V (DC +peak AC)
5 mm
10 Hz - 200 MHz
from Peak- to Peak+
Slope/Video
5 mm
0 - 200 MHz
–10 cm to +10 cm
Slope/Video
positive, negative, both
CH 1, CH 2, alt. CH 1/2 (≥ 8 mm), Line, Ext.
AC: 10 Hz-200 MHz
DC: 0 -200 MHz
HF: 30 kHz–200 MHz
LF: 0 -5 kHz
Noise Rej. switchable
pos./neg. Sync. Impulse
525 Line/60 Hz Systems
625 Line/50 Hz Systems
even/odd/both
all/line number selectable
CH 1, CH 2, Ext.
Auxiliary Input (0.3 V
AC, DC
100 V (DC +peak AC)
-100 % to +400% related to complete memory
5 mm
0 - 200 MHz
DC
–10 cm to +10 cm
A, ALT (alternating A/B), B
0.5 s/cm - 50 ns/cm (1-2-5 sequence)
20 ms/cm – 50 ns/cm (1-2-5 sequence)
± 3 %
to 5 ns/cm
± 5 %
var. 1:10 (LED-Indication)
®
HM1008
pp
, 100 MHz)
Digital mode
Accuracy time base
MEMORY ZOOM:
Bandwidth X-Amplifier:
X Y phase shift ‹ 3°:
Acquisition (real time):
Acquisition (random sampling): 10 GSa/s
Bandwidth:
Memory:
Operating modes:
Resolution (vertical):
Resolution (horizontal):
Interpolation:
Delay:
Display refresh rate:
Display:
Reference Memories:
Operation:
Save/Recall (instrument parameter settings): 9
Signal display:
Frequency counter:
Auto Measurements:
Cursor Measurements:
Resolution Readout/Cursor: 1000 x 2000 Pts, Signals: 250 x 2000
Interfaces (plug-in):
Optional:
Number of Formula Sets:
Sources:
Targets:
Functions:
Display:
CRT:
Display area (with graticule): 8 cm x 10 cm
Acceleration voltage:
Component tester
Probe ADJ Output:
Trace rotation:
Line voltage:
Power consumption:
Protective system:
Weight:
Cabinet (W x H x D):
Ambient temperature:
X Y phase shift ‹ 3°:
Time base range (1-2-5 sequence)
Refresh Mode:
with Peak Detect:
Roll Mode:
Time base:
Display:
Digital Storage
Yt:
XY:
Display:
Operation/Measuring/Interfaces
analog:
digital:
6 digit resolution:
5 digit resolution:
Accuracy:
Analog mode:
also in digital mode:
Analog mode:
plus in digital mode:
Mathematic functions
Display
General Information
Test voltage:
Test current:
Reference Potential :
‹ 220 kHz
20 ms/cm - 5 ns/cm
20 ms/cm – 2 ms/cm (min. Pulse Width 10 ns)
50 s/cm – 50 ms/cm
50 ppm
± 1 %
max. 50,000:1
0 - 100 MHz (-3 dB)
‹ 100 MHz
2x 500 MSa/s, 1 GSa/s interleaved
2 x 0 - 100 MHz (random)
1 M-Samples per channel
Refresh, Average, Envelope/
Roll: Free Run/Triggered, Peak-Detect
8 Bit (25 Pts/cm)
11 Bit (200 Pts/cm)
8 Bit (25 Pts /cm)
Sinx/x, Dot Join (linear)
1 Million * 1/Sampling Rate to
4 Million * 1/Sampling Rate
max.170/s at 1 MPts
Dots (acquired points only), Vectors (partly
interpolated), optimal (complete memory
weighting and vectors)
9 with 2 kPts each (for recorded signals)
2 signals of 9 (free selectable)
Menu (multilingual), Autoset,
help functions (multilingual)
max. 4 traces
CH 1, 2 (Time Base A) in combination with
CH 1, 2 (Time Base B)
CH1,2 and ZOOM or Reference or Mathematics)
›1 MHz – 200 MHz
0.5 Hz – 1 MHz
50 ppm
Frequency, Period, Vdc, Vpp, Vp+, Vp-
V
Δt, 1/Δt (f), t
V
RS-232 (HO710)
IEEE-488, Ethernet, Dual-Interface
RS-232/USB
5 with 5 formulas each
CH 1, CH 2, Math 1-Math 5
5 math. memories, Math 1-5
ADD, SUB, 1/X, ABS, MUL, DIV, SQ, POS,
NEG, INV
max. 2 math. memories (Math 1-5)
D14-375GH
approx. 14 kV
approx. 7 V
max. 7 mA
Ground (safety earth)
1 kHz/1 MHz square wave signal 0.2 V
(tr ‹ 4 ns)
electronic
105 – 253 V, 50/60 Hz ± 10 %, CAT II
42 Watt at 230 V, 50 Hz
Safety class I (EN61010-1)
5.6 kg
285 x 125 x 380 mm
0° C ...+40° C
rms
pp
, V
, V
p
+, V
avg
p
rms
rms
-, V
r
, ΔV, V to GND, ratio X, ratio Y
(short circuit)
avg
(open circuit), approx. 50 Hz
, V
rms
, pulse count
pp