TT-LF312-2-6 10020-2-6 TESTEC, TT-LF312-2-6 10020-2-6 Datasheet - Page 15

PROBE, OSCILLOSCOPE, DOUBLE, LOW FREQ

TT-LF312-2-6 10020-2-6

Manufacturer Part Number
TT-LF312-2-6 10020-2-6
Description
PROBE, OSCILLOSCOPE, DOUBLE, LOW FREQ
Manufacturer
TESTEC
Datasheet

Specifications of TT-LF312-2-6 10020-2-6

Svhc
No SVHC (15-Dec-2010)
Attenuation
X1 / X10
Bandwidth
150MHz
Capacitance Max
15.5pF
Input Impedance
10Mohm
Input Voltage Max
600V
Lead Length
1.2m
Rise Time
2.3ns
Technische Änderungen vorbehalten / All specifications and characteristics are subject to change without notice
Power requirements (optional): removeable battery pack (4 x AA Cells)
or Mains Adaptor 6VDC/90mA or regulated 9VDC/70mA
Dimensions: (L x W x H) 111mm x 22mm x 14mm
Length: BNC Cable 125cm - Input Leads 50cm
Weight: 300g
Specifications
- Absolute max. Voltage CAT I
- Source Impedance (typical)
(either inputs to ground)
- Common Mode Range
- Differential Range
Attenuation Ratio
Input Impedance
- Offset (typical)
- Noise (typical)
CMRR (typical)
Input Voltage
Ordernumber
Bandwidth
Rise Time
Accuracy
- Swing
Output
Type
500k
-80dB @ 100Hz, -50dB @ 10MHz
±20V (DC + peak AC or rms)
±60V (DC + peak AC or rms)
±60V (DC + peak AC or rms)
DC to 200MHz (-3dB)
±2V (into 50
// 7pF each side to ground
TT-SI 200
0,3mVrms
15135
1,75ns
<±2mV
1:10
50
±1%
Hardcase included
load)