NFK2-SMPLX-SC FLUKE NETWORKS, NFK2-SMPLX-SC Datasheet - Page 4

50 Micron, 1m, Simplex Reference Cord Set, SC/SC

NFK2-SMPLX-SC

Manufacturer Part Number
NFK2-SMPLX-SC
Description
50 Micron, 1m, Simplex Reference Cord Set, SC/SC
Manufacturer
FLUKE NETWORKS
Datasheet

Specifications of NFK2-SMPLX-SC

Kit Contents
50 UM SiSimplex Test Reference Cord Set (SC/SC X 2), 1m
Mandrel
RoHS Compliant
Model
SFPOWERMETER
SFMULTIMODESOURCE
SFSINGLEMODESOURCE
SFSINGLEMODE2
FTK1000
FTK1300
FTK1350
FTK1450
FTK2000
FTK2100
FindFiber
FindFiber-6
Model
NFK1-SMPLX-SC
NFK1-SMPLX-LC
NFK1-SMPLX-ST
NFK2-SMPLX-SC
NFK2-SMPLX-LC
NFK2-SMPLX-ST
NFK3-SMPLX-SC
NFK3-SMPLX-LC
NFK3-SMPLX-ST
NFA-SC-SINGLE
NFA-LC-SINGLE
NFA-ST-SINGLE
SimpliFiber Pro Kit Ordering Information
SimpliFiber Pro Accessories Ordering Information
Description
SimpliFiber Pro optical power meter
SimpliFiber Pro multimode 850/1300 source
SimpliFiber Pro singlemode 1310/1500 source
SimpliFiber Pro singlemode 1490/1625 source
Basic Fiber Verification Kit: Includes SimpliFiber
Pro optical power meter, 850/1300 multimode
source, and carrying case
Multimode Fiber Verification Kit: Includes
SimpliFiber Pro optical power meter,
850/1300 multimode source, VisiFault VFL,
FT120 FiberViewer, FindFiber Remote ID sources,
and carrying case; ST and LC adapter
Multimode Fiber Verification Kit with FT500
FiberInspector Mini: Includes SimpliFiber Pro
optical power meter, 850/1300 multimode source,
VisiFault VFL, FT500 FiberInspector Mini,
FindFiber Remote ID sources, and carrying case;
ST and LC adapter
Complete Fiber Verification Kit with FT500
FiberInspector Mini: Includes SimpliFiber Pro
optical power meter, 850/1300 multimode source,
1310/1550 singlemode source, VisiFault VFL,
FT500 FiberInspector Mini, two (2) FindFiber
Remote ID sources, and carrying case; ST and LC
adapter, NFC-Kit-Box fiber optic cleaning kit
Singlemode Fiber Verification Kit: Includes
SimpliFiber Pro optical power meter,
1310/1550 singlemode source, and carrying case
Singlemode Fiber Verification Kit: Includes
SimpliFiber Pro optical power meter, 1310/1550
and 1490/1625 singlemode sources, and carrying
case
One (1) FindFiber Remote ID source
Set of six (6) FindFiber Remote ID sources
Description
62.5 uM simplex reference cord set (SC/SC x 2);
special patented damage-resistant end-faces
62.5 uM simplex reference cord set (SC/LC, LC/LC);
special patented damage-resistant end-faces
62.5 uM simplex reference cord set (SC/ST, ST/ST);
special patented damage-resistant end-faces
50 uM simplex reference cord set (SC/SC x 2);
special patented damage-resistant end-faces
50 uM simplex reference cord set (SC/LC, LC/LC);
special patented damage-resistant end-faces
50 uM simplex reference cord set (SC/ST, ST/ST);
special patented damage-resistant end-faces
SM simplex reference cord set (SC/SC x 2);
special patented damage-resistant end-faces
SM simplex reference cord set (SC/LC, LC/LC);
special patented damage-resistant end-faces
SM simplex reference cord set (SC/ST, ST/ST);
special patented damage-resistant end-faces
SC interchangeable adapter
LC interchangeable adapter
ST interchangeable adapter
General Specifications
Temperature range
Humidity range
Certifications
Dimensions
Weight
Optical Sources
Optical output connector
Emitter type
Emitter wavelengths
Power output (minimum)
Power output stability
(8 hours)
MM battery life
(2 x AA IEC LR6)
SM battery life
(2 x AA IEC LR6)
FindFiber battery life
(2 x AA IEC LR6)
Optical Power Meter
Power measurement accuracy
Optical connector
Detector type
Calibrated wavelengths
Power measurement range
Power measurement linearity
Resolution
Battery life
Memory
Serial communication
physical interface
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details,
go to www.flukenetworks.com/contact.
©
Printed in U.S.A. 11/2010 3390743B D-ENG-N
2010 Fluke Corporation. All rights reserved.
Operating: -10
Storage: -20
95% (10
75% (35
uncontrolled <10
CE, CSA, N10140, Class 1 laser-safe
Power meter: 6.4 in x 3.2 in x 1.5 in
(16.5 cm x 8.0 cm x 3.9 cm)
MM/SM sources: 5.6 in x 3.2 in x 1.6 in
(14.2 cm x 8.1 cm x 4.1 cm)
Power meter: 11.5 oz (325 g)
MM/SM sources: 9.8 oz (278 g)
Fixed SC
850/1300: LED
1310/1550: FP Laser
FindFiber: Laser
850, 1300, 1310, 1490, 1550, 1625
MM: ≥ -20 dBm
SM: ≥ 8 dBm minimum;
-7 dBm nominal
MM: +/- 0.1 dB over 8 hours
SM: +/- 0.25 dB over 8 hours
40 hours typical
30 hours typical
80 hours typical
Removable adapter; SC adapter standard;
Optional adapters include LC, ST
InGaAs
850, 1300, 1310, 1490, 1550, 1625
850: 10 to -52 dBm
1300, 1310, 1490, 1550, 1625: 10 to -60
dBm
850 nm: +/- 0.2 dB; +/- 0.2 dB for power
from 0 dBm to -45 dBm, +/- 0.25 dB for
power < -45 dBm; 1300 nm, 1310 nm, 1490
nm, 1550 nm, 1625 nm: +/- 0.1 dB; +/- 0.1
dB for power from 0 dBm to -55 dBm, +/-
0.2 dB for power > 0 dBm and < -55 dBm
0.01 dB
>50 hours typical
1000 loss or power measurements
USB
+/-0.25 dB
0
0
C to 35
C to 40
0
C to 50
0
C to 50
0
0
0
C
C) non-condensing;
C) non-condensing;
0
C
0
C