N5415A AGILENT TECHNOLOGIES, N5415A Datasheet

InfiniiScan

N5415A

Manufacturer Part Number
N5415A
Description
InfiniiScan
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of N5415A

For Use With
9000 And 8000 Series Oscilloscopes
Lead Free Status / RoHS Status
na
Agilent Technologies
Infi niium 9000 Series Oscilloscopes
Data Sheet
Engineered for broadest measurement capability

N5415A Summary of contents

Page 1

... Agilent Technologies Infi niium 9000 Series Oscilloscopes Data Sheet Engineered for broadest measurement capability ...

Page 2

If you haven’t purchased an Agilent scope lately, why should you consider one now? If you’re like most engineers, you never know what your next project will demand from you. You need an oscilloscope that can adapt to a wide ...

Page 3

What makes the Infi niium 9000 Series the go-to scope for a whole range of test and debug challenges? It’s three instruments in one 1. Scope: The powerful features of our Infi niium Series oscilloscopes coupled with superior specifi cations ...

Page 4

It’s three instruments in one 1. Oscilloscope High-performance scope channels ensure superior viewing of signals under test. All models incorporate a powerful, feature-packed Infi - niium oscilloscope with responsive deep memory GHz bandwidth and 20 GSa/s high ...

Page 5

It’s three instruments in one 2. Logic analyzer MSO models add 16 high-speed timing channels with standard 128 Mpts digital memory, allowing you to retain fast 2 GSa/s sample rates over long periods of time. Use the timing channels to ...

Page 6

It’s three instruments in one 3. Protocol analyzer Does your design include a serial bus that is a key point for testing or debugging? Add protocol analysis capability to your scope for: • CAN • FlexRay • PCle • RS-232/UART ...

Page 7

Widest range of debug and compliance software applications: serial protocol-level Trigger and view on-screen serial decode packets. Trigger on and decode RS-232/UART transmission. Trigger on and decode CAN, LIN and FlexRay serial packets C/SPI ...

Page 8

Widest range of debug and compliance software applications: serial protocol and FPGA Trigger on and decode USB packets. Trigger on and decode MIPI packets Trigger on and decode PCIe serial packets. Trigger on and decode SATA serial packets 8 USB ...

Page 9

Widest range of debug and compliance software applications: serial physical-layer Check for USB compliance. Test DDR memory. Validate Ethernet compliance. Check for MIPI compliance. USB 2.0 compliance testing (N5416A or Option 029 on new scope purchases) Quickly determine USB compliance ...

Page 10

Widest range of debug and compliance software applications: Infi niiScan and jitter analysis Identify signal integrity issues with Infi niiScan Zone – Qualify triggering. Conduct jitter analysis. Analyze jitter plus RJ/DJ separation. Recover embedded clocks with serial data analysis (SDA). ...

Page 11

Widest range of debug and compliance software applications: viewing and analysis Use vector signal analysis software to see FFT-based spectrum analysis. Prove your designs conform to industry standards with a communication mask test kit. Use vector signal analysis software to ...

Page 12

Infi niium 9000 Series applications and upgrades Rapid FPGA debug. Use your scope to quickly make and analyze power measurements. increase your memory depth at any time after purchase. Upgrade your DSO to an MSO at any time after purchase. ...

Page 13

Agilent Infi niium portfolio Agilent’s real-time Infi niium lineup includes 9000, 90000A and 90000 X Series oscilloscopes. These share a number of advanced hardware and software technology blocks. Use the following selection guide to determine which best matches your specifi ...

Page 14

Agilent Infi niium 9000 Series oscilloscopes 15” XGA display makes it easier to view analog, digital and serial signals. Comprehensive built-in information system gives you fast answers to your questions. The task-oriented setup guide provides step-by-step instructions for several measurement ...

Page 15

AutoProbe interface automatically confi gures the attenuation ratio of the probe and provides probe power for Agilent’s active probes. Dedicated single acquisition button provides better control to capture a unique event. Pressing horizontal delay knob sets the delay to zero. ...

Page 16

Connectivity and probing Connectivity Industry compatibility Export screen shots and waveforms in numerous industry-standard formats. In addition, the 9000 Series supports compatibility with the following • MATLAB Basic and Advanced (add as 061 and 062 on new scope orders) • ...

Page 17

Infi niium 9000 Series performance characteristics Vertical: scope channels 1 Analog bandwidth (–3 dB) 50 Ω 1MΩ Typical Rise Time / Fall Time 10 Ω Typical Rise Time / Fall Time 20 ...

Page 18

Infi niium 9000 Series performance characteristics Vertical: scope channels (con’t) Offset accuracy 3 Dynamic range 1,2, DC voltage measurement accuracy 9064A Volts/div full BW 500 MHz fi lter 10 mV 213 uV 138 470 uV 175 uV ...

Page 19

Infi niium 9000 Series performance characteristics Horizontal Channel-to-channel skew (digital) Glitch detect (digital) Main time base range Horizontal position range Delayed sweep range Resolution Modes Reference positions Channel deskew Time scale accuracy 2,3,4,5 Delta-time measurement accuracy Absolute averaging disabled Absolute ...

Page 20

Infi niium 9000 Series performance characteristics Acquisition Maximum real-time sample rate Memory depth per channel Standard Option 50M Option 100 Option 200 Option 500 Sampling Modes Real-time Real-time with peak detect Real-time with high resolution Real-time with roll mode (200 ...

Page 21

Infi niium 9000 Series performance characteristics Trigger: digital channels MSO Models Threshold range (user defined) Threshold accuracy Measurements and math Waveform measurements Voltage (scope channels) Time (digital channels) Time (scope channels) Mixed (scope channels only) Frequency domain Level qualification Eye-diagram ...

Page 22

Infi niium 9000 Series performance characteristics Trigger modes Edge (analog and digital) Edge transition (analog) Edge then edge (time) (analog and digital) Edge then edge (event) (analog and digital) Glitch (analog and digital) Line Pulse width (analog and digital) 4 ...

Page 23

Infi niium 9000 Series performance characteristics Display Display Display intensity grayscale Resolution Annotation Grids Waveform styles Waveform update rate (10 GS/s, 50 ns/div, sin(x)/x: on) Computer system and peripherals, I/O ports Computer system and peripherals Operating system CPU PC system ...

Page 24

Infi niium 9000 Series performance characteristics General characteristics Temperature Operating Non-operating Humidity Operating Non-operating Altitude Operating Non-operating Vibration Operating Non-operating Power Typical operator noise Weight Dimensions (with feet retracted) Safety 24 5 ° °C –40 °C to ...

Page 25

Infi niium 9000 Series ordering information How to configure an Infiniium 9000 Series 1. Choose needed bandwidth 2. Choose MSO or DSO 3. Choose desired software applications 4. Choose memory depth upgrade 5. Choose any additional probes and accessories Analog ...

Page 26

Infi niium 9000 Series ordering information SW Applications RS-232/UART triggering and decode EZJIT jitter analysis software High-speed SDA and clock recovery EZJIT Plus jitter analysis software USB triggering and decode PCI Express 1.1 triggering and decode I²C/SPI triggering and decode ...

Page 27

Upgrades Post-sales upgrades → DSO MSO upgrades N2901D DSO9064A to MSO9064A Upgrade Kit N2901A DSO9104A to MSO9104A Upgrade Kit N2901B DSO9254A to MSO9254A Upgrade Kit N2901C DSO9404A to MSO9404A Upgrade Kit Oscilloscopes bandwidth upgrades N2905A Upgrade to 2.5 GHz bandwidth ...

Page 28

... Spain 34 (91) 631 3300 Sweden 0200- Switzerland 0800 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: July 8, 2010 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2011 Printed in USA, April 15, 2011 5990-3746EN ...