U3401A AGILENT TECHNOLOGIES, U3401A Datasheet - Page 14

MULTIMETER, DIGITAL, BENCH, 4-1/2 DIGIT

U3401A

Manufacturer Part Number
U3401A
Description
MULTIMETER, DIGITAL, BENCH, 4-1/2 DIGIT
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of U3401A

Dmm Type
Bench
Voltage Measuring Range Dc
500mV To 1000V
Voltage Measuring Range Ac
500mV To 750V
Current Measuring Range Dc
500µA To 10A
Current Measuring Range Ac
500µA To 10A
Lead Free Status / RoHS Status
na
Supplemental measurement specifications
Measurement
AC+DC
voltage
AC current
AC+DC
current
Resistance
Measurement method
Crest factor
Input impedance
Maximum input voltage
Overload ranging
Input protection
Response time
Measurement method
Crest factor
Shunt resistance
Input protection
Response time
Measurement method
Crest factor
Measurement range
Response time
Measurement method
Open-circuit voltage
Zeroing error
Specification
AC+DC coupled true RMS: measures the AC component with up to 400 VDC bias on any range
Maximum 3:0 at full scale
U3401A: 1 MW in parallel with <100 pF
U3402A: 1 MW ± 2% in parallel with <120 pF
U3401A: 1000 V RMS/1400 V PEAK
U3402A: 750 V RMS/1100 V PEAK
2x10
1x10
Selects higher range if peak input overload is detected during auto range. Overload is reported in
manual ranging
U3401A: 1000 V RMS on all ranges
U3402A: 750 V RMS on all ranges
Approximately 1.5 seconds (2.5 seconds for U3402A) when the displayed reading reaches 99.9% AC
RMS value of the tested input signal at the same range
DC coupled to the fuse and current shunt, AC coupled true rms measurement (measures the AC
component only)
Maximum 3:0 at full scale
U3401A
U3402A
U3401A
Front panel fuse 630 mA, 500 V; internal 25 A, 440 V
U3402A
mA input terminal: 1200 mADC or AC RMS. Protected with 1.25 A/500 V, IEC-127 sheet, FH fuse
12 A input terminal: 10 ADC or AC RMS continuous; or 12 ADC or AC RMS for 30 seconds maximum.
Protected with 15 A/600 V, breaking capacity 10,000 A FH fuse
Approximately 1.5 seconds when the displayed reading reaches 99.9% AC RMS value of the tested
input signal at the same range
AC+DC coupled to the fuse and current shunt, AC+DC coupled true rms measurement
(measures the AC component only)
Maximum 3:0 at full scale
Vdc and Vac are automatically set at the same range
Approximately 1.5 seconds when the displayed reading reaches 99.9% AC RMS value of the tested
input signal at the same range
U3401A: 2-wire ohms
U3402A: 2-wire ohms or 4-wire ohms
U3401A: Limited to <+6 VDC
U3402A: Limited to <+5 VDC
0.05 W or less (excluding test lead resistance) in each range when Relative operation is used
0.01 W to 100 W for 500 µA to 10 A ranges
0.1 W to 10 W for 10 mA to 1.2 A ranges
0.01 W for 12 A range
7
6
V-Hz product on any range, normal mode input
V-Hz product on any range, common mode input