FLUKE-77-4 Fluke, FLUKE-77-4 Datasheet

MULTIMETER, DIGITAL, HANDHELD

FLUKE-77-4

Manufacturer Part Number
FLUKE-77-4
Description
MULTIMETER, DIGITAL, HANDHELD
Manufacturer
Fluke
Datasheet

Specifications of FLUKE-77-4

Dmm Type
Handheld
Voltage Measuring Range Dc
600mV To 1000V
Voltage Measuring Range Ac
6V To 1000V
Current Measuring Range Dc
60mA To 10A
Current Measuring Range Ac
60mA To 10A
Lead Free Status / RoHS Status
na
Fluke 77 IV Series Digital Multimeter
Specifications
Voltage DC
Voltage AC
Amps AC
Amps DC
Resistance
Capacitance
Frequency
Safety
Certifications
General Specifications
Maximum voltage between
any terminal and earth
ground
Surge protection
Ω Fuse for mA inputs
Ω Fuse for A inputs
Display
Altitude
Temperature
Temperature Coefficient
Electromagnetic
Compatibility (EN 61326-
1:1997)
Range:
Best Accuracy: +/- (0.3% + 1)
Best Resolution:0.1 mV
Range:
Best Accuracy: +/- (2.0% + 2)
Best Resolution:1.0 mV
Range:
Best Accuracy: +/- (1.5% + 2)
Best Resolution:0.01mA
Range:
Best Accuracy: +/- (2.5% + 2)
Best Resolution:0.01 mA
Range:
Best Accuracy: +/- (0.5% + 1)
Best Resolution:0.1Ω
Range:
Best Accuracy: +/- (1.2% + 2)
Best Resolution:1 nF
Range:
Best Accuracy: +/- (0.1% + 1)
Best Resolution:0.01Hz
ANSI/ISA S82.02.01, CSA C22.2-1010.1, IEC 61010 to 1000 V Measurement
Category III, 600 V Measurement Category IV
CSA, TÜV (EN61010), UL, Π, ; (N10140),VDE
1000V
8 kV peak per IEC 61010
440 mA, 1000 V FAST Fuse
11 A, 1000 V FAST Fuse
Digital:
Bar Graph: 33 segments; Updates 32/sec
Frequency: 10,000 counts
Capacitance:1,000 counts
Operating:2,000 meters
Storage: 12,000 meters
Operating:-10 °C to +50 °C
Storage: -40 °C to +60 °C
0.1 X (specified accuracy / °C (< 18 °C or > 28 °C)
In an RF field of 3 V/M, accuracy = specified accuracy except in temperature:
specified accuracy ± 5 °C (9 °F)
6000 counts, updates 4/sec
6.000V - 1000V
600.0 mV-1000V
60.00 mA – 10A
60.00 mA – 10A
600.0 Ω - 50 MΩ
1nF- 9,999 µF
99.99Hz- 99.99kHz

FLUKE-77-4 Summary of contents

Page 1

... Fluke 77 IV Series Digital Multimeter Specifications Voltage DC Range: Best Accuracy: +/- (0. Best Resolution:0.1 mV Voltage AC Range: Best Accuracy: +/- (2. Best Resolution:1.0 mV Amps AC Range: Best Accuracy: +/- (1. Best Resolution:0.01mA Amps DC Range: Best Accuracy: +/- (2. Best Resolution:0.01 mA Resistance Range: Best Accuracy: +/- (0. Best Resolution:0.1Ω Capacitance Range: Best Accuracy: +/- (1. ...

Page 2

... Relative Humidity (Maximum Non-condensing) Battery Life Size Weight http://us.fluke.com/usen/products/specificat...87(FlukeProducts)&category=HMA(FlukeProducts ( [4/14/08 9:25:05 AM ° ° °C 400 Hours Typical (Alkaline) Height: 4.3 cm Width Length:18.5 cm 420 g © 1995 - 2008 Fluke Corporation ...