FLUKE-353 Fluke, FLUKE-353 Datasheet - Page 2

MULTIMETER, DIGITAL, CLAMP, 4 DIGIT

FLUKE-353

Manufacturer Part Number
FLUKE-353
Description
MULTIMETER, DIGITAL, CLAMP, 4 DIGIT
Manufacturer
Fluke
Datasheets

Specifications of FLUKE-353

Dmm Type
Clamp
Current Measuring Range Dc
0A To 2000A
Current Measuring Range Ac
0A To 2000A
No. Of Digits / Alpha
4
Dmm Response Type
True RMS
Dmm Functions
AC/DC Current
Current Ac Max
2kA
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
Specifications
Electrical specifications
Current measurement dc and ac 10 Hz to 100 Hz
Crest Factor (50/60 Hz)
*Add 2 % to error spec for CF > 2
Current measurement ac 100.1 Hz to 1 kHz
Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz
600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.
Voltage measurement (355 only) ac 100.1 Hz to 1 kHz
600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.
Ohms measurement (355 only)
2 Fluke Corporation
Range
40 A
400 A
2000 A;
1400 ac rms
Range
40 A
400 A
2000 A;
1400 ac rms
Range
4 V
40 V
400 V
600 V ac rms
1000 V dc
Range
4 V
40 V
400 V
600 V ac rms
Range
400 W
4 kW
40 kW
400 kW
Range
40 A
400 A
2000 A; 1400 ac rms
Resolution
Resolution
Resolution
Resolution
100 mV
100 mV
100 mA
100 mA
10 mV
10 mV
10 mA
10 mA
1 mV
1 mV
1 V
1 V
1 V
1 A
1 A
Fluke 355/353 True-rms 2000 A Clamp Meters
1.5 % rdg + 15 digits
3.5 % rdg + 15 digits
Crest Factor*
2 @ 33 A, 2.4 @ 27 A
2 @ 330 A, 2.4 @ 270 A
2 @ 1000 A, 2.4 @ 833 A
1.5 % rdg + 5 digits
1.5 % rdg + 5 digits
3.5 % rdg + 5 digits
3.5 % rdg + 5 digits
Accuracy > 10 A
1 % rdg + 10 digits
3 % rdg + 10 digits
Accuracy, A
1 % rdg + 5 digits
1 % rdg + 5 digits
1 % rdg + 5 digits
1 % rdg + 5 digits
3 % rdg + 5 digits
3 % rdg + 5 digits
3 % rdg + 5 digits
Accuracy
Accuracy
Resolution
Trigger Level for
Trigger Level for
100 W
0.1 W
10 W
1 W
Inrush
0.50 A
Inrush
0.50 A
5.0 A
5.0 A
5 A
5 A
Trigger Level for Hz
Trigger Level for Hz
Filter OFF
Filter OFF
0.050 V
0.050 V
0.25 V
0.25 V
N/A
6 V
6 V
6 V
6 V
Trigger Level
Trigger Level
Filter OFF
Filter OFF
for Hz
2.50 A
2.50 A
for Hz
2.5 A
2.5 A
8 A
8 A
1.5 % + 5 digits
1.5 % + 5 digits
1.5 % + 5 digits
1.5 % + 5 digits
Trigger Level for Hz
Trigger Level for Hz
Accuracy
Filter ON
Filter ON
0.050 V
0.050 V
Trigger Level
Trigger Level
0.25 V
0.25 V
N/A
6 V
6 V
6 V
6 V
Filter ON
Filter ON
for Hz
0.50 A
for Hz
0.50 A
2.5 A
2.5 A
8 A
8 A