ACDC-3400 IND Amprobe, ACDC-3400 IND Datasheet - Page 2

MULTIMETER, DIGITAL, CLAMP, 3-3/4 DIGIT

ACDC-3400 IND

Manufacturer Part Number
ACDC-3400 IND
Description
MULTIMETER, DIGITAL, CLAMP, 3-3/4 DIGIT
Manufacturer
Amprobe
Datasheet

Specifications of ACDC-3400 IND

Dmm Type
Clamp
Voltage Measuring Range Dc
660mV To 1000V
Voltage Measuring Range Ac
660mV To 750V
Current Measuring Range Dc
660A To 1000A
Current Measuring Range Ac
660A To 1000A
Lead Free Status / RoHS Status
na
ACDC-3400 IND CAT IV Industrial True RMS Clamp Meter
Specifications
DC Volts
AC Volts True RMS
AC coupled TRMS
AC Current True RMS
DC Current
Overload protection
Resistance
Amprobe® Test Tools
Input impedance
Overload protection
Peak Hold
Crest factor
Input impedance
Overload protection
Peak Hold
AC coupled TRMS
Crest factor
Overload protection
Open circuit volts
Overload protection
(valid for 23 °C ± 5 °C, for less than 75% relative humidity).
Ranges
660.0 mV, 6.600 V, 66.00 V, 660.0 V, 1000 V
660 mV: >100 MΩ; 6.6 V:10 MΩ; 66 V to 1000 V: 9.1 MΩ
1000 VDC or 750 VAC rms
Ranges
660.0 mV
6.600V, 66.00V
660.0V, 750V
Frequency*
* Frequency: 10% to 100% of voltage range
Ranges
66.00V, 660.0V, 750V
5% to 100% of range
≤ 3
660 mV: >100 MΩ; 6.6 V:10 MΩ; 66 V to 750 V: 9.1 MΩ
1000 VDC or 750 VAC rms
Ranges
660.0A
660.0A
1000 A
1000 A
Frequency*
* Frequency: 10% to 100% of current range
Ranges
660.0A, 1000A
5% to 100% of range
≤ 3
1000A AC
Range
660.0A
1000A
1000A DC
Range
660.0Ω, 6.600kΩ, 66.00kΩ, 660.0kΩ
6.600MΩ
66.00MΩ
-0.8 Vdc typical , (-1.2 Vdc on 660 Ω range)
1000 VDC or 750 VAC rms
Frequency
50 to 100 Hz
50 to 500 Hz
50 to 500 Hz
50 to 1 kHz
Frequency
50 to 500 Hz
Frequency
50 to 60 Hz
61 to 400 Hz
50 to 60 Hz
61 to 400 Hz
50 to 1kHz
Frequency
50 to 400 Hz
Accuracy
± (2.0% rdg + 5 dgts)
± (3.0% rdg + 5 dgts)
Accuracy
± (1.5% rdg + 8 dgts)
± (1.5% rdg + 8 dgts)
± (1.5% rdg + 8 dgts)
± (0.1% rdg + 5 dgts)
Accuracy
± (3.0% rdg + 300 dgts)
Accuracy
± (2.0% rdg + 10 dgts)
± (3.0% rdg + 10 dgts)
± (2.5% rdg + 10 dgts)
± (3.5% rdg + 10 dgts)
± (0.1% rdg + 5 dgts)
Accuracy
± (3.0% rdg + 200 dgts)
Accuracy
± (1.0% rdg + 5 dgts)
± (2.0% rdg + 5 dgts)
± (3.5% rdg + 5 dgts)
Accuracy
± (0.5% rdg + 2 dgts)
Data Sheet