MX0002B METRIX, MX0002B Datasheet - Page 2

ANALOGUE METER AND CLAMP

MX0002B

Manufacturer Part Number
MX0002B
Description
ANALOGUE METER AND CLAMP
Manufacturer
METRIX
Datasheet

Specifications of MX0002B

Voltage Measuring Range Dc
150mV To 1000V
Voltage Measuring Range Ac
5 To 1000V
Resistance Measuring Range
20kohm, 200kohm, 2Mohm
Current Range Dc
50µA To 10A
Current Range Ac
10A To 200A
Range Selection
Manual
External Height
150mm
External Width
98mm
Characteristics subject to modifications according to technological developments.
D i v i s i o n o f C h a u v i n A r n o u x
FRANCE
6, avenue du Pré de Challes - BP 330
74943 ANNECY-LE-VIEUX Cedex
Tel. : 33 4 50 64 22 22 - Fax : 33 4 50 64 22 13
190, rue Championnet
75876 PARIS Cedex 18
Tel. : 33 1 44 85 44 86 - Fax : 33 1 46 27 95 59
Using this continuity test with audible ‘beep’
signal connections can be checked when
carrying out resistance measurement.
An input as high as 400 Vrms results in no
damage to the device, even when carrying out
resistance measurement. This ohmmeter
function is protected by an electronic circuit
which, without a fuse, is both reliable and
extremely quick to react. The input terminals
can take transient pulses up to 6 kV.
As for the current ranges, they are protected
by high rupturing capacity (HRC) safety fuses
against 600 V.
TECHNICAL SPECIFICATION
GENERAL SPECIFICATION
• DC Voltages
• AC Voltages
• DC currents
• AC currents
• Resistances
• Continuity
• Other measurements
Protection on all ranges
Audible continuity test
MX 2B and MX 1: These hard-wearing instruments
are the “4X4’s” of the multimeter world!
Operating Temperature
Dimensions / weight
Classe de précision
Detection threshold
Chute de tension
Input Impedance
Input Impedance
Scale mid-point
Accuracy class
Accuracy class
Accuracy class
Accuracy class
Water-tightness
Length of scale
Bandwidth
Protection
Protection
Protection
Protection
Protection
Diode test
Line drop
Ranges
Ranges
Ranges
Ranges
Ranges
Supply
Safety
dB
1000 Vrms (150 V) - 1500 Vrms (500 V and 1.5 kV)
1000 Vrms (50 V) - 1500 Vrms (150 V to 1.5 kV)
320 Vrms (range
320 Vrms (range
5 V - 15 V - 50 V - 150 V - 500 V - 1,5 kV
1.6 A and 10 A fuses - 10 kA / 600 Vrms
UNITED KINGDOM
CA UK Ltd - Metrix
Waldeck House - Waldeck Road
Maidenhead SL6 8BR
Tel. : (01628) 788 888
Fax : (01628) 628 099
Electronic 400 Vrms(5s) + audible alarm
0.5 V - 1.5 V - 5 V - 15 V - 50 V -
16 Hz to 1 kHz (500 Hz / 1500 V)
In ohmmeter use an audible warning signal
lets the user know if an AC network voltage is
applied at the input.
There is also a visible indicator that lights up if
a fuse is blown.
The MX 2B comes with a current clamp for
current measurement that can be carried out
safely up to 200 A. The AM 13N clamp makes
current measurement possible without having
to break the circuit being measured.
1.6 A fuse - 10 kA / 600 Vrms
10 A
200
x 1
3
150 V - 500 V - 1.5 kV
With AM 13N clamp
AC current measurement
20 A
50 µA - 10 A
R < 150
20 k
3
2 k /V
< 0.5 V
MX 2B
x 10
15 V) - 500 Vrms (50 V) -
5 V) - 500 Vrms (15 V ) -
2 k
Safety Alarms
Yes
Yes
2.5
2.5
2
2
-
100 A
/V
3
IEC 61010-1, Cat.III, 600 V - Pollution level 2
x 100
20 k
200 A
3
40 x 98 x 150 mm / 420 g
1.5 V battery (AA, R6)
-10 to 50°C
80 mm
IP 65
For assistance and ordering
1000 Vrms (150 V) - 1500 Vrms (500 V and 1.5 kV)
1000 Vrms (50 V) - 1500 Vrms (150 V to 1.5 kV)
150 mV - 0.5 V - 1.5 V - 5 Vv - 15 V - 50 V -
50 - 500 µA - 5 - 150 - 500 mA - 1,5 - 10 A
320 Vrms (range
320 Vrms (range
5 V - 15 V - 50 V - 150 V - 500 V - 1,5 kV
1.6 A and 10 A fuses - 10 kA / 600 Vrms
1.6 A and 10 A fuses - 10 kA / 600 Vrms
Electronic 400 Vrms (5s) + audible alarm
500 µA - 5 - 150 - 500 mA - 1,5 - 10 A
The professionally designed casing is splash-
proof and, thanks to a shock-proof surround,
also resistant to knocks and drops. Its smooth
casing design also makes it easy to clean.
The MX 2B and the MX 1 are completely dou-
bly insulated devices, good for measurement
up to 1500 V. Furthermore, the SECUR’X case-
locking system prevents accidental disconnec-
ting of the measurement leads. It also prevents
the opening of the casing, to change the fuses
or the battery, whilst the measurement leads
are still connected.
16 Hz to 1 kHz (500 Hz / 1500 V)
Renowned rugged casing design
200
x 1
150 V - 500 V - 1.5 kV
Unfailing safety
1.2 V max
1.2 V max
R < 150
6.32 k /V
20 k
x 10
15 V) - 500 Vrms (50 V) -
2 k
MX 1
5 V) - 500 Vrms (15 V ) -
Yes
Yes
2.5
2.5
2.5
2
2
/V
20 k
x 100