Specifications of M101A

Voltage Measuring Range Dc
0.15V To 500V
Voltage Measuring Range Ac
1.5V To 500V
Resistance Measuring Range
1R To 1MR
Current Range Dc
50µA To 15A
Current Range Ac
1.5mA To 15A
Range
RoHS Compliant
Current Measuring Range Dc
50µA To 15A
Current Measuring Range Ac
1.5mA To
Rohs Compliant
NA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M101A
Manufacturer:
ST
0
Part Number:
M101A1
Quantity:
5 510
Part Number:
M101A1
Manufacturer:
MAXIM
Quantity:
5 510
Part Number:
M101A1
Manufacturer:
ST
0
Part Number:
M101AC
Manufacturer:
ST
0
Part Number:
M101AC
Manufacturer:
ST
Quantity:
20 000
Part Number:
M101AC(TSCDT)
Manufacturer:
ST-MICROE
Quantity:
5 495
Part Number:
M101AI
Manufacturer:
ST
Quantity:
20 000
Part Number:
M101AI/I/C
Manufacturer:
ST
0
Part Number:
M101AZ
Manufacturer:
ST
0
METRA HIT 1A and METRA HIT 2A
Analog Multimeters
METRA HIT 2A: Current Measuring Ranges
Resistance Measuring Ranges
2)
Capacitance Measuring Ranges
3)
Reference Conditions
Ambient temperature
Normal position
of use
Frequency
Line Voltage
Relative humidity
The instrument is equipped with half-wave rectification and is
RMS calibrated. It evaluates the arithmetic mean value of a
half-wave and displays different values for pulsating voltage and
current depending upon polarity.
Other influencing quantities:
Ambient Conditions
Storage temp. range -25 to 65° C (without battery)
Relative humidity
METRA HIT 2A: Accuracy (under reference conditions per IEC/EN 60 051)
Class 2.5 for
range: ±2%; in the 1.5 V~ range: +1/–2,5%,
class 2.5 for Ω (error relative to 52 mm scale length)
METRA HIT 2A: Additional accuracy class influence and Nominal Ranges of Use
Ambient temp.
Frequency
Other influencing quantities:
2
Rough measurements in the resistance measuring ranges, determination
of measured values with comparative scale
At a battery voltage of 1.5 V
Resistance
Current
150 mA
1.5 mA
15 mA
50 µA
1.5 A
x
x 10
x 100
x 1000
15 A
Capacitance
µF x 100
µF x 1000
µF x 10
µF x
1
and , max. additional intrinsic error in the 15 A
1
100Ω ... 100 kΩ
10 Ω ... 10 kΩ
3)
1 Ω ... 1 kΩ
1kΩ ... 1 MΩ
Scale Span
+23°C ±2 K
Horizontal
40 ... 60 Hz
For : sinusoidal
40 ... 60%
Up to 75%, no condensation allowed
For :
For : +13 ... +23 ... +35° C
1.5 ... 500 V ranges:
35 ... 40 ... 60 ... 1000 Hz
1.5 mA ... 1.5 A ranges:
35 ... 40 ... 60 ... 1000 Hz
15 A range:
40 ... 45 ... 60 ... 1000 Hz
0.158 V
1.16 V
1.25 V
1.25 V
1.95 V
0.43 V
Voltage Drop, Approx.
0 ... +23 ... +40° C
per IEC/EN 60 051
per IEC/EN 60 051
Value at Scale
Middle (R
2000 ... 200000 µF
180.00 Ω
18.00 Ω
18.00 kΩ
200 ... 20000 µF
1.8 0 kΩ
Scale Span
20 ... 2000 µF
2 ...
i
)
1.21 V
1.25 V
1.25 V
1.95 V
0.49 V
200 µF
Max. Measuring
Current I
0.083 mA
0.83 mA
Approx.
8.3 mA
83 mA
max
2)
,
:
Power Supply
Battery for resistance
measurement
Electrical Safety
Safety class
Measuring category
Nominal voltage
Test voltage
Fouling factor
Fuse links
METRA HIT 1A: Overload Capacity
METRA HIT 2A: Overload Capacity
1)
2)
3)
5000.0 mA –
Fuse F1 blows in the event of overloading.
Ranges are protected against overloading with PTC resistor
Max. 1 minute
150.0
500.0
500.0 mA –
150.0
500.0
0.15
15.0
50.0
50.0 µA –
50.0 mA –
0.15
15.0
50.0
150 mA –
0.5
1.5
5.0
0.5 mA –
5.0 mA –
0.5
1.5
5.0
1.5 mA –
1.5
50 µA –
15 mA –
15
Range
Range
V –
V –
V –
V –
V –
V –
V –
V –
V –
V –
V –
V –
V –
V –
V –
V –
A –
A –
500.0 mA
150.0 mA
10.0 mA
70.0 mA
20.0 mA
1.0 mA
5.0 mA
1.0 mA
5.0 mA
12.0 A
15.0 A
100 V
150 V
250 V
250 V
300 V
500 V
100 V
150 V
250 V
250 V
300 V
500 V
3.0 A
5.0 A
1.2 A
1.5 A
20 V
50 V
20 V
50 V
To
To
One 1.5 V mignon cell per IEC LR6/R6
(size AA), leak-proof
II per IEC/EN 61010-1:2001/
VDE 0411-1:2002
II
500 V
3.5 kV~
2
Replaceable
METRA HIT 1A:
F1: FF630mA/700V AC (50 kA), 6.3 x 32
F2: FF6.3A/500V AC (50 kA), 6.3 x 32
METRA HIT 2A:
F1: FF1.6A/700V AC (50 kA), 6.3 x 32
F2: FF16A/500V AC (50 kA), 6.3 x 32
Soldered permanently into place
750 mA / 600 V AC
3)
3)
1)
2)
2)
2)
2)
2)
2)
2)
3)
1)
2)
2)
2)
2)
2)
2)
2)
5000.0 mA
150.0
500.0
500.0 mA
150.0
500.0
GOSSEN METRAWATT GMBH
15.0
50.0
50.0 mA
15.0
50.0
150 mA
1.5
5.0
0.5 mA
5.0 mA
1.5
5.0
1.5 mA
1.5
15 mA
15
Range
Range
A
A
V
V
V
V
V
V
V
V
V
V
V
V
500.0 mA
150.0 mA
10.0 mA
70.0 mA
20.0 mA
5.0 mA
5.0 mA
12.0 A
15.0 A
150 V
250 V
300 V
500 V
150 V
250 V
300 V
500 V
3.0 A
5.0 A
1.2 A
1.5 A
25 V
50 V
25 V
50 V
To
To
3)
3)
2)
2)
2)
2)
2)
2)
3)
2)
2)
2)
2)
2)
2)