Specifications of 9600

Voltage Measuring Range Ac
50V To 600V
Meter Display Type
Light
Lead Free Status / RoHS Status
na

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
96001-02
Manufacturer:
SML
Quantity:
6 237
Part Number:
96001-14
Manufacturer:
HARRIS
Quantity:
6 243
Part Number:
96001-B02
Manufacturer:
HARRIS
Quantity:
6 222
Part Number:
9600DC
Manufacturer:
PHI
Quantity:
6 226
Part Number:
9600PC
Manufacturer:
NEC
Quantity:
6 240
Part Number:
9600PF4
Manufacturer:
HIFN
Quantity:
20 000
Company:
Part Number:
9600PF4
Quantity:
9 969
Part Number:
9600PF4/2
Manufacturer:
HIFN
Quantity:
20 000
Company:
Part Number:
9600PF4/2
Quantity:
9 969
22
TRIPLETT Railroad Test Sets
TRIPLETT Railroad Test Sets
Model 2000
The Model 2000 is the perfect test set when no
Cab Filters are needed.
Cat. No. 2010:
Model 2002
The Model 2002 also includes all of the
features of the Model 2000 with the addition
of Cab Filters. The Model 2002 was designed
for rapid transit / commuter type railroads
using 100Hz and 200Hz coding systems.
Cat. No. 2012:
Base unit with no Cab Filters
Upgradable to a 2001, 2002 or 2003
Auto Polarity in DC functions
Selectable DC Amps Polarity
Direct measurement of Code Parameters
Relay Contact On Time (Dry Contact)
Ohmmeter Voltage Mode detects either
Field replaceable protective window
requires no adjustment
polarity voltage including AC
100Hz and 200Hz Cab Filters
All Pass position - bypasses Cab Filters
Auto Polarity in DC functions
Selectable DC Amps Polarity
Direct measurement of Code Parameters
Relay Contact On Time (Dry Contact)
Ohmmeter Voltage Mode detects either
Field replaceable protective window
requires no adjustment
polarity voltage including AC
Model 2000
Model 2002
○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○
Model 2001
The Model 2001 includes all of the features
of the Model 2000 with the addition of Cab
Filters. The Model 2001 was designed for
passenger railroads using 100Hz and 250Hz
coding systems.
Cat. No. 2011:
Model 2003
The Model 2003 also includes all of the
features of the Model 2000 with the addition
of Cab Filters. The Model 2003 was designed
for railroads using 60Hz and 100Hz coding
systems.
Cat. No. 2013:
100Hz and 250Hz Cab Filters
All Pass position - bypasses Cab Filters
Auto Polarity in DC functions
Selectable DC Amps Polarity
Direct measurement of Code Parameters
Relay Contact On Time (Dry Contact)
Ohmmeter Voltage Mode detects either
Field replaceable protective window
requires no adjustment
polarity voltage including AC
60Hz and 100Hz Cab Filters
All Pass position - bypasses Cab Filters
Auto Polarity in DC functions
Selectable DC Amps Polarity
Direct measurement of Code Parameters
Relay Contact On Time (Dry Contact)
requires no adjustment
Ohmmeter Voltage Mode detects either
polarity voltage including AC
Field replaceable protective window
Model 2001
Model 2003
○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○
2000 Series Specifications
2000 Series Specifications
DC Voltage
Ranges:
Accuracy:
Sensitivity: 1000 ohms per volt
AC Voltage
Ranges:
Accuracy:
Sensitivity: 288 ohms per volt
Calibration: Average responding, RMS calibrated
Frequency Response: 25 Hz to 400 Hz
DC MilliAmps
Ranges:
Accuracy:
Burden Volts: 60 mV nominal
DC Amps
Ranges:
Accuracy:
Burden Volts: 60 mV nominal
AC Amps
Ranges:
Accuracy:
Burden Volts: 60 mV nominal
Calibration: Average responding, RMS calibrated
Frequency Response: 25 Hz to 400 Hz
Cab Filter Response (all AC Ranges)
60 Hz Filter:
100 Hz Filter:
200 Hz Filter:
250 Hz Filter:
All filters introduce an additional ± 1.5% level error
Code Functions (all AC and DC Ranges)
On Time:
Rate:
Peak Hold: Captures and holds highest level peak
Peak Follow: Displays all peaks > 25% of previous peaks
Ohmmeter
Voltage Sense Mode:
Resistance Measurement Mode:
Dry Contact
Allowable Contact Resistance: 0 to 100 ohms
Test Voltage:
Test Current:
On Time:
Rate:
Peak Hold: Pointer will deflect to full scale and remain there with
Power Requirements
Batteries:
Battery Life:320 hours (Typical)
Meter Movement
Electrical: 100 µ A ± 1% at full scale
Construction: Taut band, shock mounted, 100 degree deflection,
Physical Specifications
Size:
Weight:
Operating Temperature Range: -40 ° C to +85 ° C
Included Accessories
Yellow Padded Carrying Case, Shoulder Strap, Right Angle Safety
Test Leads, Batteries, Spare Fuse, Instruction Manual, Calibration
Certificate & Sticker
Warranty
One Year on Construction & Calibration
a 2.0 millisecond or longer contact closure
(can be disabled via jumper in the field)
0.6, 3, 15, 60, and 300 VDC
± 1.5% of full scale
1.5, 3, 15, 150, 300, and 600 VAC
± 3.0% of full scale
15, 60, and 300 mA DC
± 1.5% of full scale
1.5, 6, and 30 Amps DC
± 1.5% of full scale
1.5, 6, and 30 Amps AC
± 3.0% of full scale
Range:
Accuracy:
Range:
Accuracy:
Range:
Accuracy:
Sensitivity: 1000 ohms per volt
Ranges:
Center Scale: 5 and 500 ohms
Accuracy:
Open Circuit Voltage: 1.0 to 1.8 VDC
Range:
Accuracy:
Range:
Accuracy:
Two, 9 volt alkaline (NEDA 1604)
One, 1.5 volt alkaline D-cell (NEDA 13F)
2000 hours in Sleep Mode
5.0" wide x 6.5" high x 3.2" deep
Approx. 2.75 lbs. Approx. 4.75 lbs. w/ case and leads
critically damped, Mirrored Scale, Bar-ring magnet
57 to 63 Hz (2003)
92 to 100 Hz (2001, 2002 & 2003)
196 to 204 Hz (2002)
245 to 255 Hz (2001)
3% to 100%
± 3.0% of full scale
30 to 500cpm
± 3.0% of scale length
15 V AC or DC
± 20% Typical
R x 1 and R x 100
± 2% of scale length ± 0.5 ohms
7.5 to 15 VDC
830 µ A max
0 to 100 %
± 2% of full scale
30 to 500 cycles per minute
± 3% of scale length