SMD03 PEAK, SMD03 Datasheet

no-image

SMD03

Manufacturer Part Number
SMD03
Description
TWEEZERS, SMD
Manufacturer
PEAK
Datasheet

Specifications of SMD03

Svhc
No SVHC (18-Jun-2010)

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SMD030-2
Manufacturer:
TYCO
Quantity:
8 000
Part Number:
SMD030-2
Manufacturer:
RAYCHEM
Quantity:
20 000
Part Number:
SMD030F-2
Manufacturer:
Raychem
Quantity:
2 000
Part Number:
SMD030F-2
Manufacturer:
TYCO
Quantity:
20 000
Company:
Part Number:
SMD030F-2
Quantity:
994
Company:
Part Number:
SMD030F-2
Quantity:
858
Company:
Part Number:
SMD030F-2
Quantity:
1 023
Part Number:
SMD030F-2018-2
Manufacturer:
LITTELFUSE
Quantity:
1 150
Part Number:
SMD030F-2018-2
0
Part Number:
SMD03C
Manufacturer:
SECOS
Quantity:
20 000
Probe Compensation Procedure
Once the Tweezers have been connected to the Atlas LCR, it is necessary to perform a simple probe compensation
procedure. This ensures that the tweezers’ own inductance, capacitance and resistance are taken into account when
measuring components.
Ensure that the Atlas LCR is switched off, then press and hold the on-test button down until the following message is
displayed:
Probe Compensation
The Atlas LCR will then ask you to short the probes:
Please short the probes
Use the supplied Peak Dog-Tag for this purpose. Keep the
tips in good contact with the Peak Dog-Tag until the Atlas
LCR instructs you to open the probes. This is very
important if good probe compensation is to be achieved.
Now open the probes
Simply let the tweezers open and ensure that you are not touching the tips
at all.
If this has been successful, the Atlas LCR will display OK before
switching off. The Atlas LCR is now ready to use.
Peak Electronic Design Limited – Atlas House, Kiln Lane, Harpur Ind. Est., Buxton, Derbyshire, SK17 9JL, UK.
www.peakelec.co.uk Tel. +44 (0) 1298 70012 Fax. +44 (0) 1298 70046
components. Testing of components “in-circuit” will result in
unpredictable measurements.
The Atlas LCR is designed to test discrete, unconnected
Connect the Atlas LCR to the Tweezers
The pins of the tweezers cable are square section and must be
carefully inserted into the square holes of the Atlas LCR cable.
The pins do not require forcing into the sockets. If you are having
difficulty, look carefully at the orientation of the square section
hole and pin and ensure that they are aligned before inserted.
Connection polarity is unimportant for most applications.
In the interests of development, information in this guide is subject to change without notice
Surface Mount Device Probe Tweezers
©
User Guide Supplement
Peak Electronic Design Limited 2003
for the Atlas LCR
Model SMD03
E&OE
electronic design ltd