72-8150 TENMA, 72-8150 Datasheet - Page 24

Capacitance Meter With Resistance

72-8150

Manufacturer Part Number
72-8150
Description
Capacitance Meter With Resistance
Manufacturer
TENMA
Datasheet

Specifications of 72-8150

Accuracy %
2%
External Height
6.77"
External Width
3.27"
External Depth
1.5"
No. Of Batteries
1
Kit Contents
Capacitance Meter, Test Clips, Owners Manual, 1 9V Battery
Lead Free Status / RoHS Status
na
C. Replacing the Fuse (see figure 8)
To avoid injury due to electrical shock or arc blast,
and to avoid damage to the Meter, use specified fuses
ONLY in accordance with the following procedure.
To replace the Meter’s fuse:
1.
2.
3.
4.
5.
6.
7.
Turn the Meter power off and remove all connections
from the terminals.
Remove the screw from the battery compartment, and
separate the battery compartment from the case bottom.
Remove the screws from the case bottom, and separate
the case top from the case bottom.
Remove the fuse by gently prying one end loose, then
take out the fuse from its bracket.
Install ONLY replacement fuses with the identical type
and specification as follows and make sure the fuse is
fixed firmly in the bracket.
Fuse 1: 0.315A, 250V, fast type fuse, 5x20 mm.
Replace the battery compartment and the case top, and
reinstall the screw.
Replace the case bottom and case top, and reinstall the
screws.
Warning
(figure 8)
24
Model 72-8150: OPERATING MANUAL