KCG0601 Kingstate Electronics Corp., KCG0601 Datasheet - Page 5

MAGNETIC TRANSDUCER, PIN TYPE

KCG0601

Manufacturer Part Number
KCG0601
Description
MAGNETIC TRANSDUCER, PIN TYPE
Manufacturer
Kingstate Electronics Corp.
Datasheet

Specifications of KCG0601

Transducer Function
Buzzer
Current Rating
80mA
Resonant Frequency
3kHz
Sound Level Spl
77dB
Sound Level Distance
10cm
Coil Resistance
6ohm
Current Consumption
80mA
External Diameter
6.6mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KCG0601
Manufacturer:
KINGSTATE
Quantity:
20 000
G. ENVIRONMENT TEST 環境測試
H. RELIABILITY TEST 信賴性測試
TEST CONDITION.
Standard Test Condition : a) Temperature : +5 ~ +35℃ b) Humidity : 45-85%
Judgement Test Condition : a) Temperature : +25 ± 2℃
No.
No.
1
2
3
4
1
溫度/溼度循環測試
Operating
一般測試條件
爭議時測試條件
壽命測試
Temp./ Humidity
High temp. test
Thermal Shock
life test
Low temp. test
Item
熱衝擊試驗
高溫測試
低溫測試
Item
Cycle
志豐電子股份有限公司 KINGSTATE ELECTRONICS CORP 5/6
1.Continuous life test 高溫壽命測試(連續)
2.Intermittent life test 室溫壽命測試(間歇)
The part shall be subjected to 72 hours at +45℃ with 1.5V ,3000Hz
applied.
在+45℃環境下,輸入 1.5V ,3000Hz 連續操作 72 小時.
A duty cycle of 1 minute on, 1 minutes off, a minimum of 10000 times
at room temp.( +25±10℃) with 1.5V ,3000Hz applied.
在室溫下(+25±10℃), 輸入 1.5V ,3000Hz 通電 1 分鐘/斷電 1 分鐘,測試
10000 次循環.
:
: a) 溫度 : +25 ± 2℃
After being placed in a chamber at +70℃ for 96 hours.
置於+70℃環境中 96 小時
After being placed in a chamber at -30℃ for 96 hours.
置於-30℃環境中 96 小時
The part shall be subjected to 10 cycles. One cycle shall consist
of; 對單體施以熱衝擊試驗 10 次循環,其循環內容如圖示
The part shall be subjected to 10 cycles. One cycle shall be 24
hours and consist of;
單體承受溫度/溼度循環測試 10 次.其循環內容如圖示
+70℃
+25℃
a) 溫度 : +5 ~ +35℃
-30℃
30 min.
3hrs
a
Test condition
60 min.
12±0.5hrs
Test condition
b
+70℃
24hours
30 min.
3hrs
b) 濕度 : 45-85%
b) Humidity : 60-70%
b) 濕度 : 60-70%
c
a,b : 90~98%RH
c : 80~98%RH
c) Pressure : 860-1060mbar
c) 氣壓 : 860-1060mbar
c) Pressure : 860-1060mbar
c) 氣壓 : 860-1060mbar
KCG0601
After the test the part shall
meet specifications
with-out any degradation
in appearance and
performance except SPL.
after 4 hours at +25℃.
經測試後, 靜置於+25℃
(室溫)環境中 4 小時後,
單體除音壓外, 外觀及電
氣特性須符合規格. 輸出 音
壓變化量須在±10dBA 內.
After the test the part shall
meet specifications
with-out any degradation
in appearance and
performance except SPL.
after 4 hours at +25℃.
經測試後, 靜置於+25℃
(室溫)環境中 4 小時後,
單體除音壓外, 外觀及電
氣特性須符合規格. 輸出 音
壓變化量須在±10dBA 內.
Evaluation standard
Evaluation standard
the SPL should be in
±10dBA compared with
initial one.
the SPL should be in
±10dBA compared with
initial one.

Related parts for KCG0601