884X-SHORT Fluke, 884X-SHORT Datasheet - Page 2

no-image

884X-SHORT

Manufacturer Part Number
884X-SHORT
Description
4-Wire Short
Manufacturer
Fluke
Datasheets

Specifications of 884X-SHORT

Accessory Type
4 Terminal Shorting Bar
For Use With
Shorting DMM Input Source And Sense Terminals
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
Test leads, probes, and probe tips
8845A-EFPT Fine Point Extended Test Probe
Adapter Set
Specifications
TL2X4W-PTII 2X4 Wire Ohms Test Lead
Specifications
Materials
Color
Safety
Operating
voltage
Current
Maximum voltage between test lead and ground:
1000 V
Maximum transient overvoltage and input voltage
combined: 1000 V
Maximum current: 500 mA
Temperature
Altitude
Safety
One pair (red
Snaps onto
Designed to
Adapter allows access to hard-to-reach test
Tips are insulated to the point to prevent short-
Perform 4-
Two conduc-
Excellent resolution and accuracy
and black)
DMM probes
with .080 in
(2 mm) O.D.
Tips
IEC 1010 standard
points
ing of adjacent components
wire measure-
ments with
only two test
leads
tors per lead
(one source
and one
measure)
Tip: Stainless steel Tip insulation:
Kynar Body: Polypropylene, fire
retardant, UL94 V-2 rated
One red, one black
IEC 1010-2-031, Category II, P2
compliant
300 V rms/dc
3 A
Operating: 0 to 55 °C < 90 %
relative humidity
Storage: -40° C to 170 °C
2000 m
Complies with EN/IED 61010-031
and CAN/CSA C22.2 No. 61010-1-
04 for Measurement Category 1
1000 V
cont.
884X-Short 4-wire short
884x-RTD 100 Ohm RTD
Temperature Probe
Specifications
Resistance
Temperature coefficient 0.00385 Ω/Ω °C nominal
Temperature range
Drift rate
Sheath material
Leads
Termination
Time constant
Bending radius
Calibration
Immersion
Accuracy (includes cali-
bration uncertainty and
short-term stability)
Size
Marking
4-terminal shorting bar
4 mm banana terminals
Used to null out front end
Manufactured using a
Mineral-insulated
sized and orientated to
short DMM input source and
sense terminals
offsets or as required by the
calibration procedure
coil suspension element
design for increased
shock and vibration
resistance
sheath with a minimum
bend radius of 19 mm
(3/4 in) for flexibility
and durability
Nominal 100 Ω
-200 °C to 300 °C (transition and cable
temperature: 0 °C to 150 °C)
+ 0.13 °C at 0 °C after 1000 hours at
300 °C
316 stainless steel
Teflon
copper, 22 AWG
4-wire banana
Four seconds maximum for 63.2 %
response to step change in water moving
at 3 fps
19 mm (3/4 in) except for 50 mm (2 in)
area of sheath near tip
Includes manufacturer’s NIST-traceable
calibration and table with R vs. T values
in 1 °C increments from -196 °C to 300 °C.
Callendar – van Dusen coefficients
included
At least 100 mm (4 in) recommended
± 0.050 °C at -196 °C
± 0.050 °C at 0 °C
± 0.051 °C at 200 °C
± 0.055 °C at 300 °C
9 in L x 3/16 in diameter
Each RTD is marked with the Fluke name
and part number
-insulated, nickel-plated stranded

Related parts for 884X-SHORT