66102 EATON POWERWARE/MGE OFFICE PROTECTION, 66102 Datasheet - Page 55

Network Management Card

66102

Manufacturer Part Number
66102
Description
Network Management Card
Manufacturer
EATON POWERWARE/MGE OFFICE PROTECTION
Datasheet

Specifications of 66102

For Use With
Central UPS Systems That Protect A Complete Network Or For UPS Systems Providing Back-up For Critical Equipment

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
66102-8
Manufacturer:
TE
Quantity:
20 000
Part Number:
66102-8
Manufacturer:
yazaki
Quantity:
17 000
Part Number:
66102-9
Manufacturer:
TE/AMP
Quantity:
30 000
Part Number:
66102-9
Manufacturer:
TE
Quantity:
48 000
Part Number:
66102-9
Manufacturer:
TE
Quantity:
35 000
Load not powered
UPS internal fault
Battery fault
UPS overload
UPS overtemperature
Imminent UPS shutoff
<Sensor name>: Humidity is above high threshold xx %
<Sensor name>: Temperature is below low threshold xx °C
<Sensor name>: Humidity is below low threshold xx %
<Sensor name>: <Input #1 label> <when closed label>
<Sensor name>: <Input #1 label> <when open label>
<Sensor name>: <Input #2 label> <when closed label>
<Sensor name>: <Input #2 label> <when open label>
7.1.2 Table of UPS events
List of time dated informations
Alarm on
Battery fuse blown
Battery temperature fault
Battery charger fault
Charger temperature fault
End of Warranty
End of battery life
End of life of the wearing parts
Outlet 1 open
Outlet 2 open
Chopper fault
Normal AC switch (Q1) open
Normal AC frequency out of tolerance
Normal AC fuses blown
Normal AC module fault
Normal AC voltage out of tolerance
Automatic Bypass switch (Q4S) open
Bypass AC frequency out of tolerance
Automatic Bypass fault
Automatic Bypass overload
Automatic Bypass overtemperature
Bypass AC phase out of tolerance
Automatic Bypass thermal overload
Load not protected - On Automatic Bypass
Bypass AC voltage out of tolerance
T H E
Network Management Card – User Manual
<Sensor name>: Temperature is above high threshold xx °C <Sensor name>: La température est au dessus du
U N I N T E R R U P T I B L E
P O W E R
34003991EN/GA
Load powered
UPS OK
Battery OK
UPS returns to normal load
UPS temperature OK
UPS OK
seuil haut xx °C
<Sensor name>: L'humidité est au dessus du seuil
haut xx %
<Sensor name>: La température est en dessous du
seuil bas xx °C
<Sensor name>: L'humidité est en dessous du seuil
bas xx %
<Sensor name>: <Input #1 label> <when closed label>
<Sensor name>: <Input #1 label> <when open label>
<Sensor name>: <Input #2 label> <when closed label>
<Sensor name>: <Input #2 label> <when open label>
Alarm off
Battery fuse OK
Battery temperature OK
Battery charger OK
Charger temperature OK
LCM message OK
LCM message OK
LCM message OK
Outlet 1 closed
Outlet 2 closed
Chopper OK
Normal AC switch (Q1) closed
Normal AC frequency OK
Normal AC fuses OK
Normal AC module OK
Normal AC voltage OK
Automatic Bypass switch (Q4S) closed
Bypass AC frequency OK
Automatic Bypass OK
Automatic Bypass load OK
Automatic Bypass temperature OK
Bypass AC phase OK
Automatic Bypass load OK
Load protected - Return from Bypass
Bypass AC voltage OK
P R O V I D E R
- 55 -

Related parts for 66102