MSO8104A AGILENT TECHNOLOGIES, MSO8104A Datasheet

OSCILLOSCOPE, 1GHZ, 20 CHANNEL, 4GSPS

MSO8104A

Manufacturer Part Number
MSO8104A
Description
OSCILLOSCOPE, 1GHZ, 20 CHANNEL, 4GSPS
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of MSO8104A

Scope Type
Analog / Digital
Scope Channels
4 Analog + 16 Digital
Bandwidth
1GHz
Meter Display Type
XGA TFT-LCD Color
Sampling Rate
4GSPS
Input Impedance
1Mohm
Rise Time
350ps
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Agilent Technologies
Infiniium 8000 Series Oscilloscopes
Superior mixed-signal analysis and debug
Data Sheet

MSO8104A Summary of contents

Page 1

... Agilent Technologies Infiniium 8000 Series Oscilloscopes Superior mixed-signal analysis and debug Data Sheet ...

Page 2

... DSO or MSO. With built-in GPIB and low 5U high profi le, it's ideal for rackmount applications. Infiniium 8000 Series oscilloscopes Model Bandwidth DSO8064A 600 MHz MSO8064A 600 HHz DSO8104A 1 GHz MSO8104A 1 GHz 2 Sample rate Standard memory 4-ch/2-ch 4-ch/2-ch 2 GSa/s/4 GSa/s 4 Mpts/8 Mpts 2 GSa/s/4 GSa/s ...

Page 3

What makes the Infiniium 8000 Series flexible enough for a whole range of test and debug challenges? Great measurement capability Oscilloscope: The powerful features of our Infi niium Series oscilloscopes, coupled with good scope specifi cations give you excellent signal ...

Page 4

Oscilloscope capabilities Scope channels ensure superior viewing of signals under test. All models incorporate a powerful, feature-packed Infi niium oscilloscope with responsive deep memory GHz bandwidth and 4 GSa/s high sample rates guarantee you’ll see a good ...

Page 5

MSO capabilities MSO models add 16 high-speed timing channels Use the timing channels to evaluate control signal relationships and data buses bits wide. Use symbols to more quickly interpret waveforms. Digital and mixed-signal trigger Trigger on and ...

Page 6

... Infiniium Features DSO8064A/MSO8064A, DSO8104A/MSO8104A Serial, parallel and wideband signal decode Whether you are working on serial, parallel or wideband signals, you can use the 8000 Series to decode your waveforms. When you are working on parallel waveforms, you can even customize the bus states to be displayed on the decode table ...

Page 7

... Infiniium Features (continued) DSO8064A/MSO8064A, DSO8104A/MSO8104A Simple zooming Zooming with Infiniium’s graphical user interface is simple and convenient. Just use the mouse to draw a box around the area of interest and click inside. Zoom uses the full display so you get meaningful vertical as well as horizontal resolution gains. ...

Page 8

... Infiniium Features (continued) DSO8064A/MSO8064A, DSO8104A/MSO8104A AutoMask and mask test Mask testing is simplified with AutoMask. Acquire a waveform, define tolerance limits, and create a test envelope. Mask testing provides a pass/fail comparison of an incoming signal to the test envelope. Easily test your design’s conformance to industry standards with the communication mask test kit option ...

Page 9

Connectivity and probing Connectivity Industry compatibility Export screen shots and waveforms in numerous industry-standard formats. In ad- dition, the 8000 Series supports compatibility with the following • IVI COM driver for application development environments such as Visual Studio, Agilent VEE, ...

Page 10

Up to 128 Mpts of MegaZoom fast deep memory sustains maximum sample rates for long time captures. Remote access via Web browser or programming environment with GPIB commands over LAN allows you to access your oscilloscope from any networked PC. ...

Page 11

MegaZoom technology enables you to quickly pan and zoom through the deepest waveforms for detailed analysis. USB 2.0 port directly on front panel makes it easy to save files to a USB mass storage device. AutoProbe interface completely configures your ...

Page 12

Agilent Infi niium portfolio Agilent’s Infi niium lineup includes 8000, 9000 and 90000A Series oscilloscopes. These share a number of advanced hardware and software technology blocks. Use the following selection guide to determine which best matches your specifi c needs. ...

Page 13

Infiniium Advanced Application Software The Agilent 8000 Series Infiniium oscilloscope offers a broad portfolio of add-on applications that enables you to customize your oscilloscope. These applications are available as add-on options at your initial scope purchase or as user-installed options ...

Page 14

Infiniium Advanced Application Software Automotive serial data analysis software (Option 008 or N5402A) The N5402A automotive serial data analysis software allows engineers to view both protocol layer information and physical layer signal characteristics for CAN and FlexRay buses inside a ...

Page 15

Infiniium Advanced Application Software EZJIT jitter analysis software (Option 002 or E2681A) The E2681A jitter analysis option provides the most commonly needed jitter measurements, including cycle- cycle jitter, N-cycle jitter, period jitter, time interval error, setup and hold time, measurement ...

Page 16

Infiniium Advanced Application Software USB 2.0 performance validation and compliance software (N5416A) The Infiniium USB 2.0 electrical performance validation and compliance option provides a fast and reliable way to verify USB electrical specification compliance for USB 2.0 devices, hosts, and ...

Page 17

Infiniium Advanced Application Software Infiniium user-defined function (Option 010 or N5430A) The Agilent N5430A Infiniium user- defined function opens up new possibilities for mathematical analysis features of Infiniium by creating a gateway to MATLAB from MathWorks (www.mathworks.com/). You can now ...

Page 18

... In addition, a selection of probes that specifically enhances or utilizes Infiniium 8000 Series are also listed. System bandwidth 1 GHz with MSO8104A and DSO8104A 600 MHz with MSO8064A and DSO8064A 1 GHz with MSO8104A and DSO8104A 1 600 MHz with MSO8064A and DSO8064 ...

Page 19

... Dynamic range 2,4 DC voltage measurement accuracy* Dual cursor Single cursor DSO8064A, MSO8064A, DSO8104A, MSO8104A DSO8064A/DSO8104A: 4 analog MSO8064A/MSO8104A: 4 analog + 16 digital DSO8064A/MSO8064A: 600 MHz DSO8104A/MSO8104A: 1 GHz DSO8064A/MSO8064A: 583 ps DSO8104A/MSO8104A: 350 ps 1 MΩ ± 1% (13 pF typical), 50 Ω ± 1.5% 1 mV/div to 5 V/div (1 MΩ) 1 mV/div to 1 V/div (50 Ω ...

Page 20

... MSO8064A, MSO8104A 16 digital – labeled D15 – D0 Pod 1: D7 – D0 Pod 2: D15 – D8 TTL, 5.0V CMOS, 3.3V CMOS, 2.5V CMOS, ECL, PECL, user defined ±8. increments ±40 V peak CAT I ±(100 threshold setting) ± ...

Page 21

... Modes Reference positions Jitter measurement floor Time interval error Period jitter N-cycle, cycle-cycle jitter (continued) DSO8064A, MSO8064A, DSO8104A, MSO8104A DSO8064A/MSO8064A 500 ps/div to 20 s/div 0 to ± 200 s 1 ps/div to current main time base setting 4 ps ±( • (years since manufacture)) ppm Values apply to period measurements of 0.5 Vpp sine waves with frequencies equal to 1/2 the oscilloscope bandwidth at 100 mV/div using ≥ ...

Page 22

... Filters (Sin[x])/x Interpolation Acquisition: digital channels Maximum input frequency Maximum real time sample rate Memory depth per channel Minimum width glitch detection 22 (continued) DSO8064A, MSO8064A, DSO8104A, MSO8104A 4 GSa/s 2 GSa/s 250 GSa/s 2 channels/4 channels 8 Mpts/4 Mpts 16 Mpts/8 Mpts 32 Mpts/16 Mpts 64 Mpts/32 Mpts ...

Page 23

... TV Violation triggers Pulse width Setup/hold Transition (continued) DSO8064A, MSO8064A, DSO8104A, MSO8104A DC to 600 MHz: 0.6 div 600 MHz to 1 GHz: 1.5 div (50 Ω 600 MHz: 300 mVp-p ± 8 div from center screen (1 MΩ) ± 8 div from center screen (50 Ω) ± ...

Page 24

... Software triggers on the user-defined zones on screen. Zones can be specified as either “must intersect” or “must not intersect.” four zones can be defined. MSO8064A, MSO8104A ±8 10-mV increments ±(100 threshold setting) TTL=1.4 V, 5.0 V CMOS=2.5 V, 3.3 V CMOS=1.65 V, 2.5 V CMOS=1.25 V, ECL=–1.3 V, PECL=3 ...

Page 25

... Signal-to-noise ratio Window modes (continued) DSO8064A, MSO8064A, DSO8104A, MSO8104A Peak-to-peak, minimum, maximum, average, RMS, amplitude, base, top, overshoot, preshoot, upper, middle, lower, runt (with InfiniiScan) Period, frequency, positive width, negative width, duty cycle, delta time Rise time, fall time, Tmin, Tmax, channel-to-channel phase, setup time, hold time ...

Page 26

Infiniium Performance Characteristics Display Display Display Intensity grayscale: Resolution Annotation Grids Waveform styles Waveform update rate Real time mode (nominal) Computer system and peripherals, I/O ports Computer system and peripherals Operating system CPU PC system memory Drives Peripherals File types ...

Page 27

... FFT amplitude readings are affected by input amplifier roll-off; DSO8064A and MSO8064A: – 600 MHz, with amplitude decreasing as frequency increases above 600 MHz; DSO8104A and MSO8104A: – GHz, with amplitude decreasing as frequency increases above 1 GHz. 8 Noise floor varies with memory depth and with averaging on or off. ...

Page 28

... GSa/s 4 GSa/s 4 GSa/s 8 Mpts 8 Mpts 8 Mpts 1 Description 16 Mpts on 2 channels, 8 Mpts on 4 channels 32 Mpts on 2 channels, 16 Mpts on 4 channels 64 Mpts on 2 channels, 32 Mpts on 4 channels 128 Mpts on 2 channels, 64 Mpts on 4 channels MSO8104A 1 GHz 4 analog + 16 logic 4 GSa/s 8 Mpts ...

Page 29

Infiniium Ordering Information Application options Options Description Digital analysis N5397A FPGA dynamic probe for Xilinx N5433A FPGA dynamic probe for Altera Serial data analysis Option 007 or N5391A Low-speed serial data analysis software for I Option 008 or N5402A Automotive ...

Page 30

Infiniium Ordering Information Other options Option Description Option 017 ≥ removable hard disk drive. Replaces ≥ internal hard disk with a ≥ (factory installed) removable hard disk. Order the N5422A for additional hard disk ...

Page 31

... N5416A USB 2.0 Electrical Performance Validation and Compliance Software U7233A DDR1 Compliance Test Application N5415A InfiniiScan Event Identification Software N5430A Infiniium User-Defined Function Application Software Multiple form factors from 20 MHz to >90 GHz 2 C and SPI Agilent Technologies Oscilloscopes | Industry leading specs Publication type Publication number Data sheet 5968-7141EN/ENUS ...

Page 32

... Spain 34 (91) 631 3300 Sweden 0200- United Kingdom 44 (0) 118 9276201 For other unlisted Countries: www.agilent.com/find/contactus Revised: October 14, 2010 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2011 Printed in USA, January 14, 2011 5989-4271EN ...