LAN8187-JT SMSC, LAN8187-JT Datasheet - Page 43

Ethernet ICs HiPerfrm Ethrnt PHY

LAN8187-JT

Manufacturer Part Number
LAN8187-JT
Description
Ethernet ICs HiPerfrm Ethrnt PHY
Manufacturer
SMSC
Type
MII/RMII Ethernet Transceiverr
Datasheet

Specifications of LAN8187-JT

Ethernet Connection Type
10 Base-T, 100 Base-TX
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Product
Ethernet Transceivers
Number Of Transceivers
1
Standard Supported
802.3ab
Data Rate
10 MB, 100 MB
Supply Voltage (max)
3.3 V
Supply Voltage (min)
1.8 V
Supply Current (max)
39 mA, 81.6 mA
Maximum Operating Temperature
+ 70 C
Package / Case
TQFP-64
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LAN8187-JT
Manufacturer:
Standard
Quantity:
1 040
Part Number:
LAN8187-JT
Manufacturer:
STM
Quantity:
5 362
Part Number:
LAN8187-JT
Manufacturer:
SMSC
Quantity:
20 000
Company:
Part Number:
LAN8187-JT
Quantity:
114
±15kV ESD Protected MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX & flexPWR
Datasheet
SMSC LAN8187/LAN8187i
ADDRESS
ADDRESS
ADDRESS
ADDRESS
3.15:10
4.11:10
2.15:0
3.9:4
3.3:0
4.15
4.14
4.13
4.12
1.4
1.3
1.2
1.1
1.0
Note: For Revision “B” devices, the default Revision Number is 3h.
PHY ID Number
Revision Number
PHY ID Number
Auto-Negotiate
Pause Operation
Jabber Detect
Remote Fault
Model Number
Capabilities
Remote Fault
Link Status
Extended
Next Page
Reserved
Reserved
NAME
Ability
NAME
NAME
NAME
Table 5.34 Register 4 - Auto Negotiation Advertisement
Table 5.31 Register 1 - Basic Status (continued)
1 = remote fault condition detected
0 = no remote fault
1 = able to perform auto-negotiation function
0 = unable to perform auto-negotiation function
1 = link is up,
0 = link is down
1 = jabber condition detected
0 = no jabber condition detected
1 = supports extended capabilities registers
0 = does not support extended capabilities registers
Assigned to the 3rd through 18th bits of the
Organizationally Unique Identifier (OUI), respectively.
OUI=00800Fh
Assigned to the 19
Six-bit manufacturer’s model number.
Four-bit manufacturer’s revision number.
Table 5.32 Register 2 - PHY Identifier 1
Table 5.33 Register 3 - PHY Identifier 2
1 = next page capable,
0 = no next page ability
This Phy does not support next page ability.
1 = remote fault detected,
0 = no remote fault
00 = No PAUSE
01 = Symmetric PAUSE
10 = Asymmetric PAUSE toward link partner
11 = Both Symmetric PAUSE and Asymmetric
PAUSE toward local device
DATASHEET
DESCRIPTION
th
DESCRIPTION
DESCRIPTION
DESCRIPTION
43
through 24
®
Technology
th
bits of the OUI.
MODE
MODE
MODE
R/W
MODE
RW
RO
RO
RO/
RO/
RO/
RW
RW
Revision 1.7 (03-04-11)
RW
RW
RO
RO
LH
LH
LL
DEFAULT
DEFAULT
DEFAULT
DEFAULT
0007h
C0h
0Ch
00
4h
0
0
0
0
1
0
0
1

Related parts for LAN8187-JT