MAX7314ATG-T Maxim Integrated Products, MAX7314ATG-T Datasheet - Page 7

no-image

MAX7314ATG-T

Manufacturer Part Number
MAX7314ATG-T
Description
Communication ICs - Various
Manufacturer
Maxim Integrated Products
Type
Hot Insertion Protectionr
Datasheet

Specifications of MAX7314ATG-T

Mounting Style
SMD/SMT
Operating Supply Voltage
2.5 V, 3.3 V
Supply Type
Analog
Package / Case
TQFN-24 EP
Data Rate
400 Kbps
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2 V
Supply Current
0.057 mA
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Input ports registers reflect the incoming logic levels of
the port pins, regardless of whether the pin is defined
as an input or an output. Reading an input ports regis-
ter latches the current-input logic level of the affected
eight ports. Transition detection allows all ports config-
ured as inputs to be monitored for changes in their
logic status. The action of reading an input ports regis-
ter samples the corresponding 8 port bits’ input condi-
tion. This sample is continuously compared with the
actual input conditions. A detected change in input
condition causes the INT/O16 interrupt output to go
low, if configured as an interrupt output. The interrupt is
cleared either automatically if the changed input
returns to its original state, or when the appropriate
input ports register is read.
The INT/O16 pin can be configured as either an inter-
rupt output or as a 17th output port with the same static
or blink controls as the other 16 ports (Table 4).
The two blink phase 0 registers set the output logic lev-
els of the 16 ports P0–P15 (Table 8). These registers
control the port outputs if the blink function is disabled.
A duplicate pair of registers, the blink phase 1 registers,
are also used if the blink function is enabled (Table 9).
In blink mode, the port outputs can be flipped between
using the blink phase 0 registers and the blink phase 1
registers using hardware control (the BLINK input)
and/or software control (the blink flip flag in the configu-
ration register) (Table 4). The logic level of the BLINK
input can be read back through the blink status bit in
the configuration register (Table 4). The BLINK input,
therefore, can be used as a general-purpose logic input
(GPI port) if the blink function is not required.
Figure 2. 2-Wire Serial Interface Timing Details
Port Output Control and LED Blinking
Port Inputs and Transition Detection
SDA
SCL
t
HD,STA
START CONDITION
18-Port GPIO with LED Intensity Control,
_______________________________________________________________________________________
Interrupt, and Hot-Insertion Protection
t
LOW
t
R
t
SU,DAT
t
HIGH
t
F
t
HD,DAT
t
REPEATED START CONDITION
SU,STA
The MAX7314 includes an internal oscillator, nominally
32kHz, to generate PWM timing for LED intensity control.
PWM intensity control can be enabled on an output-by-
output basis, allowing the MAX7314 to provide any mix
of PWM LED drives and glitch-free logic outputs (Table
10). PWM can be disabled entirely, in which case all out-
put ports are static and the MAX7314 operating current
is lowest because the internal oscillator is turned off.
PWM intensity control uses a 4-bit master control and 4
bits of individual control per output (Tables 13, 14). The
4-bit master control provides 16 levels of overall intensi-
ty control, which applies to all PWM-enabled output
ports. The master control sets the maximum pulse
width from 1/15 to 15/15 of the PWM time period. The
individual settings comprise a 4-bit number, further
reducing the duty cycle to be from 1/16 to 15/16 of the
time window set by the master control.
For applications requiring the same PWM setting for all
output ports, a single global PWM control can be used
instead of all the individual controls to simplify the con-
trol software and provide 240 steps of intensity control
(Tables 10 and 13).
When the serial interface is idle and the PWM intensity
control is unused, the MAX7314 automatically enters
standby mode. If the PWM intensity control is used, the
operating current is slightly higher because the internal
PWM oscillator is running. When the serial interface is
active, the operating current also increases because
the MAX7314, like all I
transmission.
t
HD,STA
2
C slaves, has to monitor every
t
SU,STO
PWM Intensity Control
CONDITION
STOP
t
BUF
Standby Mode
CONDITION
START
7