CS44600-CQZR Cirrus Logic Inc, CS44600-CQZR Datasheet - Page 63

Audio Amplifiers 6ch 24-bit 192kHz Dig. Amp Cntrlr T&R

CS44600-CQZR

Manufacturer Part Number
CS44600-CQZR
Description
Audio Amplifiers 6ch 24-bit 192kHz Dig. Amp Cntrlr T&R
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS44600-CQZR

Operating Supply Voltage
2.5 V
Supply Current
150 mA
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 10 C
Supply Type
Digital
Supply Voltage (max)
2.62 V
Supply Voltage (min)
2.37 V
Package / Case
LQFP-64
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
DS633F1
7.22.2 SRC Lock Interrupt (SRC_LOCK)
7.22.3 Ramp-Up Complete Interrupt (RMPUP_DONE)
7.22.4 Ramp-Down Complete Interrupt (RMPDN_DONE)
7.22.5 Mute Complete Interrupt (Mute_DONE)
7.22.6 Channel Over Flow Interrupt (OVFL_INT)
7.22.7 GPIO Interrupt Condition (GPIO_INT)
Default = 0
Function:
When high, indicates that on all active channels, the sample rate converters have achieved lock. This
interrupt is an edge-triggered event.
If this bit is set to a 1b, indicating a lock condition, and an SRC_UNLOCK condition is detected, then this
bit will be reset to 0b before a read of the Interrupt Status Register. Only the last valid state of the SRC
will be reported.
Default = 0
Function:
When high, indicates that all active channels have completed the configured ramp-up interval.
Default = 0
Function:
When high, indicates that all active channels have completed the configured ramp-down interval.
Default = 0
Function:
When high, indicates that all muted channels have completed the mute cycle-down interval as defined by
the SZC[1:0] bits in the
Default = 0
Function:
When high, indicates that the magnitude of an output sample on one of the channels has exceeded full
scale and has been clipped to positive or negative full scale as appropriate. This bit is the logical OR of
all the bits in the Channel Over Flow Status Register. Read the Channel Over Flow Status Register to
determine which channel(s) had the overflow condition.
Default = 0
Function:
When high, indicates that a transition as configured on one of the un-masked GPIO pins has occurred.
This bit is the logical OR of all the supported un-masked bits in the GPIO Status Register. Read the GPIO
Status Register to determine which GPIO input(s) caused the interrupt condition. The GPIO interrupt is
not removed by reading this register. The GPIO Status Register must be read to clear this interrupt. If the
GPIO input is configured as “edge trigger” the interrupt will clear. If the GPIO input is configured as “level
sensitive”, the interrupt condition will remain as long as the GPIO input remains at the active level.
“Volume Control Configuration (address 06h)” on page
55.
CS44600
63