10014 3M Interconnect Solutions, 10014 Datasheet

no-image

10014

Manufacturer Part Number
10014
Description
Manufacturer
3M Interconnect Solutions
Type
Splice Terminalr
Datasheet

Specifications of 10014

Body Plating
Tin
Body Material
Copper
Insulation
Non-Insulated
Product Depth (mm)
27mm
Color
Not Required
Lead Free Status / RoHS Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
10014-3
Manufacturer:
RFMD
Quantity:
5 000
Part Number:
10014-3
Manufacturer:
ANAREN
Quantity:
20 000
Part Number:
10014-30
Manufacturer:
M/A-COM
Quantity:
5 000
Part Number:
10014-30
Manufacturer:
ANAREN
Quantity:
20 000
Part Number:
100141-1
Manufacturer:
TYCO
Quantity:
37 629
Company:
Part Number:
100141F
Quantity:
2 235
Part Number:
100141F*
Manufacturer:
S/PHI
Quantity:
104
Part Number:
100141F****
Manufacturer:
CY
Quantity:
240
Part Number:
100141FC
Manufacturer:
FSC
Quantity:
56
Part Number:
100141FC
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
100143434
Manufacturer:
ST
0
Part Number:
100143434
Manufacturer:
ST
Quantity:
20 000
Part Number:
100144FC
Manufacturer:
NSC
Quantity:
200
Part Number:
100145-501
Manufacturer:
ST
0
Part Number:
100145717
Manufacturer:
ST
0
Scotchlok
10000 Series
Data Sheet
1. Product Description
Scotchlok
tors consist of a series of inline connectors
from 6 AWG through 1,000 kcmil (MCM)
designed for connecting copper conductors.
Each connector is tin plated to resist corro-
sion and can be installed with standard in-
dustry tooling. Chamfered ends and cable
stops ensure simplicity and ease of installa-
tion.
The Scotchlok connectors consist of a series
of compression sleeves from 6 AWG
through 1,000 kcmil and a series of long-
barreled sleeves from 2/0 through 1,000
kcmil.
The connector features are:
— One-piece, seamless tin-plated copper.
— Simple application using readily
— Cable stops in center of connector.
— Chamfered ends for ease of conductor
— U.L. Listed, CSA Certified.
— Both standard and long-barrel connec-
— U.L. Listed with Burndy, T&B and
2. Applications
— To splice copper conductors from
— Low voltage and high voltage (up to
— For maximum current-carrying
available tools.
insertion.
tors are available in most sizes.
Anderson crimping tools.
6 AWG through 1,000 kcmil.
35 kV).
requirements, long-barreled connectors
are available.
Copper Compression Connec-
Copper Compression Connectors
3. Data
Physical and Electrical
The Scotchlok 10000 and 11000 series cop-
per connectors, crimped with approved die
sets, can be used on cables with a rated oper-
ating temperature of 90 C and an emergen-
cy overload rating of 130 C.
3A.
Connector
Scotchlok
Number
10001
10002
10003
10004
10005
10006
10007
10008
10009
10010
10014
10019
10024
11006
11007
11008
11009
11010
10011
11011
11014
11019
11024
Conductor
(AWG or
kcmil)
1000
1000
LISTED
Size
250
250
300
300
350
350
500
500
750
750
1/0
2/0
2/0
3/0
3/0
4/0
4/0
540H
6
4
2
1
CONNECTOR DIMENSIONS AND SELECTION GUIDE
Dimensions in Inches and (Millimeters)
4.13 (104,8)
4.13 (104,8)
4.63 (117,5)
5.88 (149,3)
6.13 (155,6)
1.75 (44,4)
1.75 (44,4)
1.88 (47,7)
1.88 (47,7)
1.88 (47,7)
2.00 (50,8)
3.13 (79,4)
2.13 (54,0)
3.13 (79,4)
2.13 (54,0)
3.38 (85,8)
2.25 (57,2)
3.38 (85,8)
2.25 (57,2)
2.38 (60,4)
2.88 (73,1)
3.38 (85,8)
3.88 (98,5)
Length
0.39 (10,0)
0.43 (11,2)
0.43 (11,2)
0.49 (12,4)
0.49 (12,4)
0.54 (13,9)
0.54 (13,9)
0.59 (15,1)
0.59 (15,1)
0.65 (16,5)
0.65 (16,5)
0.70 (17,8)
0.70 (17,8)
0.83 (21,2)
0.83 (21,2)
1.03 (26,2)
1.03 (26,2)
1.17 (29,8)
1.17 (29,8)
0.19 (5,0)
0.24 (6,2)
0.30 (7,8)
0.35 (9,1)
Diameter
Table 1
Inside
The connectors pass the requirements of UL
486A, Underwriters Laboratories standards
for safety. The current rating of these con-
nectors meets or exceeds the current rating
of the conductor size for which it is in-
tended.
0.41 (10,6)
0.46 (11,7)
0.51 (13,0)
0.56 (14,2)
0.56 (14,2)
0.61 (15,7)
0.61 (15,7)
0.68 (17,4)
0.68 (17,4)
0.75 (19,0)
0.75 (19,0)
0.81 (20,7)
0.81 (20,7)
0.87 (22,2)
0.87 (22,2)
1.06 (27,0)
1.06 (27,0)
1.29 (33,0)
1.29 (33,0)
1.50 (38,1)
1.50 (38,1)
0.29 (7,3)
0.34 (8,6)
Diameter
Outside
0.025 (0,64)
0.025 (0,64)
0.025 (0,64)
0.025 (0,64)
0.030 (0,76)
0.030 (0,76)
0.030 (0,76)
0.030 (0,76)
0.030 (0,76)
0.040 (1,00)
0.040 (1,00)
0.040 (1,00)
0.040 (1,00)
0.040 (1,00)
0.040 (1,00)
0.045 (1,14)
0.045 (1,14)
0.050 (1,40)
0.050 (1,40)
0.070 (1,80)
0.070 (1,80)
0.080 (2,03)
0.080 (2,03)
Chamfer
Orange
Orange
Brown
Green
Purple
Purple
Yellow
Yellow
Brown
Brown
Color
Code
Black
Black
White
White
Black
Black
Grey
Blue
Pink
Red
Red

Related parts for 10014

10014 Summary of contents

Page 1

... 2.25 (57,2) 0.65 (16,5) 11010 300 4.13 (104,8) 0.65 (16,5) 10011 350 2.38 (60,4) 0.70 (17,8) 11011 350 4.13 (104,8) 0.70 (17,8) 10014 500 2.88 (73,1) 0.83 (21,2) 11014 500 4.63 (117,5) 0.83 (21,2) 10019 750 3.38 (85,8) 1.03 (26,2) 11019 750 5 ...

Page 2

... BG (4) 10009 250 W166 (3) 11009 250 W166 (4) 10010 300 — 11010 300 — 10011 350 — 11011 350 — 10014 500 — 11014 500 — 10019 750 — 11019 750 — 10024 1000 — 11024 1000 — * Y45 and Y46 accept all Y35 dies (“U” series). For Y45 use PT6515 adapter. For Y46 use PUADP adapter. ...

Page 3

... Installation Techniques Make connections for Scotchlok compres- sion connectors with the approved crimping tool and die sets as listed in Table 2. When inserting conductors, make sure ends are pushed tight against cable stops ...

Page 4

Important Notice Electrical Products Division 6801 River Place Blvd. Austin, TX 78726-9000 Recycled paper 40% pre-consumer 10% post-consumer ...

Related keywords