0-0035115-0 TE Connectivity, 0-0035115-0 Datasheet

no-image

0-0035115-0

Manufacturer Part Number
0-0035115-0
Description
Manufacturer
TE Connectivity
Type
Splice Terminalr
Datasheet

Specifications of 0-0035115-0

Wire Gauge
14-22
Body Plating
Tin
Body Material
Copper
Insulation
Nylon
Product Depth (mm)
8.71mm
Product Length (mm)
17.27mm
Color
Natural
Lead Free Status / RoHS Status
Compliant
Product Facts
Catalog 65472
Revised 04-04
www.tycoelectronics.com
For single and multiple wire
applications
Nylon or vinyl or PVF
insulated
Temperature ratings of
90°C, 105°C, 150°C
300V, 600V or 1000V rated
Crescent crimp configura-
tion
Covers wire ranges from
24 to 6 AWG [0.2 to 16 mm
509 to 42,700 CMA
Copper or steel splice
material
Plated or unplated
Solid or stranded copper
wire
and
approved
2
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
2
]
Closed End Splices
AMP Pre-insulated Closed
End Splices have been
designed specifically to
a n s w e r the need for inex-
pensive, insulated electrical
terminations. They can be
used in almost every type
of commercial application
where multiple wires need
to be brought together for
a reliable termination. (e.g.
large and small appliances
and the lighting industry).
The Closed End Splice
p roducts described in this
catalog accommodate wire
sizes from 24 through 6
AWG [0.2 to 16 mm
to 42,700 CMA. The appeal
of Closed End Splice pro d-
ucts lies in their bro a d
range of wire sizes, built in
p re-insulation, ease and
speed of application, uni-
f o rm re l i a b i l i t y, and low
installed cost.
As is true of all AMP termi-
nal and splice lines, careful-
ly engineered application
tooling has been developed
for the Closed End Splice
line to provide uniformly
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
2
] 509
high quality terminations.
Tool and terminal have
been designed as a team
to promote ease and speed
of application and at the
same time to provide pre-
cise crimping pressure for
every wire size combina-
tion. This connection
provides maximum
conductivity, tensile
strength, and high
resistance to corrosion.
The quality of performance,
the facility of installation
and the inherent simplicity
of Closed End Splices
make them ideal for many
industrial applications.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
Need more information?
Call Technical Support at the
numbers listed below.
Technical Support is staffed
with specialists well versed
in Tyco Electronics
products. They can provide
you with:
© Copyright 1994 by Tyco Electronics
All Rights Reserved.
AMP, BOMB-TAIL, CERTI-CRIMP,
AMP-TAPETRONIC are Trademarks.
Technical Support
Catalogs
Technical Documents
Product Samples
Tyco Electronics
Authorized Distributor
Locations
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK:44-141-810-8967
1

Related parts for 0-0035115-0

0-0035115-0 Summary of contents

Page 1

... Nylon or vinyl or PVF 2 insulated Temperature ratings of 90°C, 105°C, 150°C 300V, 600V or 1000V rated Crescent crimp configura- tion Covers wire ranges from AWG [0 509 to 42,700 CMA Copper or steel splice material Plated or unplated Solid or stranded copper wire and approved ...

Page 2

... Bulk package 2 Catalog 65472 Dimensions are in inches and Revised 04-04 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. Closed End Splices Vinyl BOMB-TAIL Splices — VS, ECV L Opening Dim. Dia. Material Color Max. Min. .750 .173 Blue Copper 19 ...

Page 3

... Closed End Splices Nylon Molded Splices — ECN, EC Wire Size Range AWG [0 CMA 509 to 13,100 Wire Size Wire Insulation [ Combination Color Circular Mils Charts Trans. 408- 22-14 1271 [0.3-2.0] Trans. 509-5,180 408- Black 8806 Trans. 408- 1021 Trans. 408- ...

Page 4

... Model 2614 or 1210 are the recommended tool 1 Bulk packaged 3 With foot pedal control 4 These dies may be used with Model 2614 Pneumatic Tool and Straight Action Adapter part number 354173-1 ...

Page 5

... C [ 0.3-3.0 ] 46866 C 2907 (46516) C 3,248-11,400 **Where listed Model 2614 or 1210 are the recommended tool 1 Bulk packaged 3 With foot pedal control 4 These dies may be used with Model 2614 Pneumatic Tool and Straight Action Adapter Part Number 354173-1 5 Model 2614 may be ordered with either a foot pedal or hand actuator 6 Limited wire size range ...

Page 6

... Wire Size Range AWG [0 CMA 509 to 13,100 Material Copper Tin plated Insulation — Nylon Wire Size Dimension [ Style Circular Mils Unstripped — Wire 22-18 Stripped [ 0.3-0.8.5 ] Wire 509-3,248 16-14 Stripped [ 1.4-2.0 ] Wire 2,050-5,180 12-10 Stripped [ 3.0-6.0 ] Wire 5,180-13,100 Unstripped — ...

Page 7

... These dies may be used with Model 2614 Pneumatic Tool and Straight Action Adapter part number 354173-1 5 Model 2614 may be ordered with either a foot pedal or hand actuator 6 Limited wire size; see Instruction Sheet 408-9906 Catalog 65472 Dimensions are in inches and Revised 04-04 millimeters unless otherwise specified ...

Page 8

... WIRE SIZE 22-10 SOL. OR STR. 600 Volt Max. Building Wiring 105°C 1000 Volt Max. Fixtures & Signs MAX. NO. OF ADDITIONAL WIRES OF ONE WIRE SIZE WIRE NO. OF SIZE WIRES NO. 22 NO. 20 NO. 18 NO. 16 NO. 14 NO 4-14 3-8 2-7 2 3-13 2-7 1-6 3 ...

Page 9

... ULLISTED AND CSACERTIFIED WIRE COMBINATIONS WIRE SIZE 22-10 SOL. OR STR. 424 C 300 Volt Max. 90°C Max. LISTED NO. OF ADDITIONAL WIRES OF ONE WIRE SIZE WIRE NO. OF SIZE WIRES NO. 22 NO. 20 NO. 18 NO. 16 NO. 14 NO 4-12 3-8 2-7 1-4 2 3-11 2-7 1-6 1-3 3 ...

Page 10

... SOL. OR STR. WIRE COMB. CHAR T Catalog No.34306,34349 & 34864 Circular Mil Range 3,248 — 4,872 Use “18- 16-14 ECV” Tooling Strip Length— 8.73 mm [.344 in.] Min .— 10.32 mm [.406 in.] Max. ULLISTED AND CSACERTIFIED WIRE COMBINATIONS WIRE SIZE 22-16 SOL. OR STR. ...

Page 11

... Strip Length — 11.11 mm [.438 in.] Min.— 12.70 mm [.500 in.] Max. ULLISTED AND CSACERTIFIED WIRE COMBINATIONS WIRE SIZE 22-10 SOL. OR STR. 424 C 300 Volt Max. 90°C Max. LISTED NO. OF ADDITIONAL WIRES OF ONE WIRE SIZE WIRE NO. OF SIZE WIRES NO. 22 NO. 20 NO. 18 NO. 16 NO. 14 NO 5-6 3-5 2 4-5 3-4 2 ...

Page 12

... WIRE SIZE 18-6 SOL. OR STR. LISTED 600 Volt Max. Building Wiring 1000 Volt Max. Fixtures & Signs 105°C MAX. NO. OF ADDITIONAL WIRES OF ONE WIRE SIZE WIRE NO. OF SIZE WIRES NO. 18 NO. 16 NO. 14 NO 12-15 7-13 5-7 2 11-14 7-12 4-7 3 10-13 ...

Page 13

... Strip Length— 10.72 mm [.422 in.] Min.— ULLISTED AND CSACERTIFIED WIRE LR 7189 424 C CERTIFIED LISTED 105°C MAX. WIRE NO. OF NO. 18 NO. 16 SIZE WIRES NO. 22 NO. 20 NO. 18 NO. 16 NO. 14 NO. 12 NO. 10 2-7 1-4 1 4-14 1-6 1-3 2 3-13 1-6 1-3 3 2-12 1-5 ...

Page 14

... Strip Length—10.72 mm [.422 in.] Min.— 11.51 mm [.453 in.] Max. ULLISTED AND CSACERTIFIED WIRE COMBINATIONS WIRE SIZE 22-10 SOL. OR STR. 300 Volt Max. 105°C Max. NO. OF ADDITIONAL WIRES OF ONE WIRE SIZE NO. OF WIRES NO. 22 NO. 20 NO. 18 NO. 16 NO. 14 NO 4-16 3-9 2-7 1-4 1-2 2 3-15 2-8 ...

Page 15

... Dimensions are in inches and Revised 04-04 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. 408-2907 TO BE SOLD ONLY WITH CU INSTALLATION INSTRUCTIONS Use “18-10 ECV— ECN or 22-14 ECN” Tooling 424 C LISTED WIRE NO. OF NO. 14 NO. 12 SIZE WIRES 1-4 1-2 1 ...

Page 16

... Max. ULLISTED AND CSACERTIFIED WIRE COMBINATIONS WIRE SIZE 22-10 STR. 300 Volt Max. 150°C [302°F] Max. NO. OF ADDITIONAL WIRES OF ONE WIRE SIZE NO. OF WIRES NO. 22 NO. 20 NO. 18 NO. 16 NO. 14 NO 4-14 3-8 2-7 1-4 1-2 2 3-13 2-7 ...

Related keywords