PQ40120QGA08NRS-G SYNQOR, PQ40120QGA08NRS-G Datasheet
PQ40120QGA08NRS-G
Specifications of PQ40120QGA08NRS-G
Related parts for PQ40120QGA08NRS-G
PQ40120QGA08NRS-G Summary of contents
Page 1
... UL/cUL 60950-1 recognized (US & Canada), basic insulation rating • TUV certified to EN60950-1 • Meets 72/23/EEC and 93/68/EEC directives which facilitates CE Marking in user’s end product • Board and plastic components meet UL94V-0 flamma- bility requirements www.synqor.com T echnical T echnical S pecification S ...
Page 2
... Notes: 1. SENSE(–) should be connected to Vout(–) either remotely or at the converter. 2. Leave TRIM pin open for nominal output voltage. 3. SENSE(+) should be connected to Vout(+) either remotely or at the converter. www.synqor.com Input: 18-75 V 18-75 V Input: 12.0 V Output: 12.0 V Output: 8.33 A Current: 8.33 A ...
Page 3
... Isolation Voltage (dielectric strength) Isolation Resistance 2 Isolation Capacitance Note 1: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Note 2: Higher values of isolation capacitance can be added external to the module. Product # PQ40120QGA08 Phone 1-888-567-9596 =48Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C ambient tem- Min ...
Page 4
... Needle Flame Test (IEC 695-2-2) IEC 61000-4-2 GR-1089-CORE Telcordia (Bellcore) GR-513 • An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or download from the SynQor website. QUALIFICATION TESTING Parameter P # Units ...
Page 5
... C (nominal input voltage, 48V input). ° Figure 6: Thermal plot of converter at 8.33 amp load current with 55 air flowing at the rate of 200 LFM. Air is flowing across the converter sideways from pin 3 to pin 1 (24V input). www.synqor.com Input: 18-75 V 18-75 V Input: 12.0 V Output: 12.0 V Output: 8 ...
Page 6
... Figure 12: Thermal plot of converter at 8.1 amp load current with 85 air flowing at the rate of 200 LFM. Air is flowing across the converter from input to output (48V input). www.synqor.com Input: 18-75 V 18-75 V Input: 12.0 V Output: 12.0 V Output: 8 ...
Page 7
... ESR capacitor tantalum capacitor Figure 18: Input Terminal Ripple Current full rated output cur- rent and nominal input voltage with 10 electrolytic capacitor (200 mA/div). See Figure 17. www.synqor.com Doc.# 005-2QG128D Rev. A Input: 18-75 V 18-75 V Input: 12.0 V Output: 12.0 V Output: 8 ...
Page 8
... Vin 48 Vin -80 75 Vin -90 -100 10,000 100,000 Figure 24: Magnitude of incremental forward transmission ( out / for minimum, nominal, and maximum input voltage at full rated power. www.synqor.com Input: 18-75 V 18-75 V Input: 12.0 V Output: 12.0 V Output: 8.33 A Current: 8.33 A Current: Quarter-brick P ackage: ...
Page 9
... Figure 26: Magnitude of incremental input impedance ( for minimum, nominal, and maximum input voltage at full rated power. +80 ºC +25 ºC -40 ºC 20.0 19.5 19.0 18.5 18 www.synqor.com Input: 18-75 V 18-75 V Input: 12.0 V Output: 12.0 V Output: 8.33 A Current: 8.33 A Current: Quarter-brick P ackage: Quarter-brick ...
Page 10
... Note: the output over-voltage protection circuit senses the voltage across the output (pins 8 and 4) to determine when it should trig- ON/OFF ON/OFF Vin( _ Vin Positive Logic (Permanently Enabled) 5V TTL/ ON/OFF CMOS Vin Direct Logic Drive www.synqor.com Input: 18-75 V 18-75 V Input: 12.0 V Output: 12.0 V Output: 8.33 A Current: 8.33 A Current: Quarter-brick P ackage: ...
Page 11
... Decrease in Vout when the temperature at the sensed location reaches the Over- Temperature Shutdown value. It will allow the converter to turn on again when the temperature of the sensed location falls by the amount of the Over-Temperature Shutdown Restart Hysteresis value. www.synqor.com Input: 18-75 V 18-75 V Input: 12.0 V Output: 12 ...
Page 12
... Input System Instability: This condition can occur because any DC/DC converter appears incrementally as a negative resistance load. A detailed application note titled “Input System Instability” is available on the SynQor website which provides an understanding of why this instability arises, and shows the preferred solution for correcting it. ...
Page 13
... Substances) Directive bans the use of Lead, Cadmium, Hexavalent Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor product is 6/6 RoHS compliant. For more information please refer to SynQor’s RoHS addendum available at our RoHS Compliance / Lead Free Initiative web page or e-mail us at rohs@synqor ...
Page 14
... SynQor. Information furnished by SynQor is believed to be accurate and reliable. However, no responsibility is assumed by SynQor for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SynQor ...