IRG4BC20K International Rectifier, IRG4BC20K Datasheet
IRG4BC20K
Specifications of IRG4BC20K
Available stocks
Related parts for IRG4BC20K
IRG4BC20K Summary of contents
Page 1
Features Features Features Features Features • High short circuit rating optimized for motor control, t =10µs, @360V V (start 15V GE • Combines low conduction losses with high switching speed • Latest generation design provides ...
Page 2
... IRG4BC20K Electrical Characteristics @ T Parameter V Collector-to-Emitter Breakdown Voltage (BR)CES Emitter-to-Collector Breakdown Voltage T V (BR)ECS Temperature Coeff. of Breakdown Voltage (BR)CES J V Collector-to-Emitter Saturation Voltage CE(ON) V Gate Threshold Voltage GE(th Temperature Coeff. of Threshold Voltage GE(th) J Forward Transconductance Zero Gate Voltage Collector Current CES I Gate-to-Emitter Leakage Current ...
Page 3
... Fig Typical Output Characteristics www.irf.com uty c yc le: 50 125° 90°C sink G ate drive as spec ified tio Frequency (kHz) (Load Current = I of fundamental) RMS 100 150 150 15V Fig Typical Transfer Characteristics IRG4BC20K T ria 50V CC 5µs PULSE WIDTH Gate-to-Emitter Voltage ( ...
Page 4
... IRG4BC20K 100 T , Case Temperature ( C Fig Maximum Collector Current vs. Case Temperature 0.50 1 0.20 0.10 0.05 0.1 0.02 0.01 SINGLE PULSE (THERMAL RESPONSE) 0.01 0.00001 0.0001 Fig Maximum Effective Transient Thermal Impedance, Junction-to-Case 15V PULSE WIDTH 4.0 3.0 2.0 1.0 125 150 -60 -40 -20 ° ...
Page 5
... Gate Resistance ( G G Fig Typical Switching Losses vs. Gate Resistance www.irf.com SHORTED 100 0 Fig Typical Gate Charge vs 0.1 -60 -40 - Fig Typical Switching Losses vs. IRG4BC20K = 400V = 9. Total Gate Charge (nC) G Gate-to-Emitter Voltage 50 = Ohm = 15V = 480V 9. 4 100 120 140 160 ° Junction Temperature ( ...
Page 6
... IRG4BC20K 5 Ohm 150 C ° 480V 15V 4.0 GE 3.0 2.0 1.0 0 Collector-to-emitter Current (A) C Fig Typical Switching Losses vs. Collector-to-Emitter Current 6 100 V = 20V 125 SAFE OPERATING AREA Fig Turn-Off SOA o 10 100 1000 , Collector-to-Emitter Voltage (V) www.irf.com ...
Page 7
... Clamped Inductive Load Test Circuit D river* 50V 1000V www.irf.com 480V . ff t=5µ IRG4BC20K 480V 25° 480µF 960V Fig. 13b - Pulsed Collector Current Test Circuit Fig. 14a - Switching Loss Test Circuit * Driver same type as D.U.T 480V Fig. 14b - Switching Loss Waveforms 7 ...
Page 8
... IRG4BC20K Notes: Q Repetitive rating 20V, pulse width limited by GE max. junction temperature. ( See fig. 13b ) 80%( 20V 10µ CES GE (See fig. 13a (. 2 2 (.255 (.240 (. (. 1.15 (. 4.06 (.160 (. 3.55 (.140) 0.93 (.037 0.69 (.027 (. (. (. (. CONFORMS TO JEDEC OUTLINE TO-220AB IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 ...
Page 9
Note: For the most current drawings please refer to the IR website at: http://www.irf.com/package/ ...