NI 5-G12-AP6X 50MM TURCK, NI 5-G12-AP6X 50MM Datasheet - Page 3

no-image

NI 5-G12-AP6X 50MM

Manufacturer Part Number
NI 5-G12-AP6X 50MM
Description
NI 5-G12-AP6X 50MM
Manufacturer
TURCK
Type
Inductiver
Datasheet

Specifications of NI 5-G12-AP6X 50MM

Body Style
Cylindrical
Function
Proximity
Output
PNP
Primary Type
Proximity
Range, Measurement
5 mm
Technology
Inductive
Termination
3-Wire Cable
Led Indicator
Output Energized (Additional Power on LED, Terminal Chamber Versions)
Environment Rating
NEMA 1, 3, 4, 6, 13; IP67
Operating Temperature
–13°F to +158°F
Voltage Drop
1.8 VDC at Max. Load Current
Sensors
General Specifications
M33
2-Wire AC w/o Short-Circuit Protection
Line Frequency. . . . . . . . . . . . . . . . . . . . . . . . . . . 40-60 Hz
Differential Travel (Hysteresis) . . . . . . . . . . . . . . . . . . . 3-15% (5% typical)
Voltage Drop Across Conducting Sensor . . . . . . . . . . . . . .
Continuous Load Current . . . . . . . . . . . . . . . . . . . . .
Off-State (Leakage) Current . . . . . . . . . . . . . . . . . . . .
Minimum Load Current . . . . . . . . . . . . . . . . . . . . . .
Inrush Current . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-On Effect . . . . . . . . . . . . . . . . . . . . . . . . . . Per IEC 947-5-2
Transient Protection . . . . . . . . . . . . . . . . . . . . . . . . Per EN 60947-5-2
Shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 g, 11 ms
Vibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Hz, 1 mm Amplitude in all 3 Planes
2-Wire DC AS-Interface
Ripple . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Differential Travel (Hysteresis) . . . . . . . . . . . . . . . . . . . 3-15% (5% typical)
Voltage Drop Across Conducting Sensor . . . . . . . . . . . . . .
Off-State (Leakage) Current . . . . . . . . . . . . . . . . . . . . <100 A
No-Load Current . . . . . . . . . . . . . . . . . . . . . . . . . . <30 mA
Time Delay Before Availability . . . . . . . . . . . . . . . . . . .
Power-On Effect . . . . . . . . . . . . . . . . . . . . . . . . . . Per IEC 947-5-2
Transient Protection . . . . . . . . . . . . . . . . . . . . . . . . Per EN 60947-5-2
Shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 g, 11 ms
Vibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Hz, 1 mm Amplitude in all 3 Planes
Repeatability . . . . . . . . . . . . . . . . . . . . . . . . . . . . £2% of Rated Operating Distance
E/A Configuration . . . . . . . . . . . . . . . . . . . . . . . . . (HEX)/ID-Code (HEX) 1/1
I/O Matrix Input . . . . . . . . . . . . . . . . . . . . . . . . . . 0=Switching Signal
I/O Matrix Input . . . . . . . . . . . . . . . . . . . . . . . . . .
I/O Matrix Input . . . . . . . . . . . . . . . . . . . . . . . . . .
2-Wire AC/DC w/Short-Circuit Protection
Line Frequency. . . . . . . . . . . . . . . . . . . . . . . . . . . 40-60 Hz
Differential Travel (Hysteresis) . . . . . . . . . . . . . . . . . . . 3-15% (5% typical)
Voltage Drop Across Conducting Sensor . . . . . . . . . . . . . .
Trigger Current for Overload Protection . . . . . . . . . . . . . . AC: 440 mA; DC: 330 mA
Continuous Load Current . . . . . . . . . . . . . . . . . . . . . AC: 400 mA; DC: 300 mA
Off-State (Leakage) Current . . . . . . . . . . . . . . . . . . . .
Minimum Load Current . . . . . . . . . . . . . . . . . . . . . .
Inrush Current . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.0 A ( 20 ms, 10% Duty Cycle)
Power-On Effect . . . . . . . . . . . . . . . . . . . . . . . . . . Per IEC 947-5-2
Transient Protection . . . . . . . . . . . . . . . . . . . . . . . . Per EN 60947-5-2
Shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 g, 11 ms
Vibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Hz, 1 mm Amplitude in all 3 Planes
Repeatability . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
8 and 12 mm 6.0 V at 100 mA
8 and 12 mm 100 mA
Bi 2-Q8SE-Ap/AN..£5% of Rated Operating Distance
1-3= Not Used
0-3-3= Not Used
8 and 12 mm 6.0 V at 100 mA
8 and 12 mm AC: 120 mA; DC: 120 mA
8 and 12 mm AC: 100 mA; DC: 100 mA
6.0 V at 400 mA
400 mA
1.7 mA
5.0 mA
8.0 A ( 10 ms, 5% Duty Cycle)
10%
1.8 V at 200 mA
6.0 V at 400 mA
1.7 mA (AC)
1.5 mA (DC)
3.0 mA
2% of Rated Operating Distance
ms

Related parts for NI 5-G12-AP6X 50MM