MF010-0-LC1 Honeywell Sensing and Control, MF010-0-LC1 Datasheet - Page 3

no-image

MF010-0-LC1

Manufacturer Part Number
MF010-0-LC1
Description
GAS SENSORS
Manufacturer
Honeywell Sensing and Control
Series
-r
Type
Oxygenr
Datasheet

Specifications of MF010-0-LC1

Oxygen Range
1 mbar ~ 250 mbar
Accuracy
±2%
Output
0 ~ 10 V
Operating Temperature
-10°C ~ 50°C
Voltage - Supply
22.8 V ~ 25.2 V
Current - Supply
500mA
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Figure 1. Dimensional Drawing and Pinout (For reference only: mm/in.)
Figure 2. System Block Diagram
Order Guide
Catalog Listing
MF010 Series
MF020 Series
1 kOhm + LED
Ø26,5
[1.04]
[0.83]
21,0
Calibration
Varies with catalog listing.
Ø12,0
[0.47]
See Table 1.)
External Monitoring
(4 mA to 20 mA
User-Specified
or 0 V to 10 V
Connection Cable
Output)
Device
Description
Low temperature oxygen sensor (See Table 1 for specifics.)
High temperature oxygen sensor (See Table 2 for specifics.)
[0.35]
Ø9,0
0 V
MF010/MF020
Sensor
[3.46]
88,0
Supply
24 Vdc
Ø0,21
Power
[5.3]
105,0
[4.13]
[2.36]
60,0
Test
[1.09]
27,7
Ground
[0.83]
21,0
[0.69]
[1.18]
17,5
30,0
[0.55]
14,0
[1.65]
[1.38]
42,0
35,5
Figure 3. Sensor Mounting
Bar Probe
[1.67]
42,5
O-Ring
Weld Socket
Partition
Nut
1
2
3
4
5
6
7
Housing
Pin
Oxygen Sensors
Honeywell Sensing and Control
50 °C [122 °F] Max.
ground
Atmospheric Air
+24 Vdc
0 V
not assigned
input +24 Vdc
Channel 1
(4 mA to 20 mA)
Channel 2 (I/O)
calibration switch
15°
Partition
5
6
0 V or 4 mA = 0 Vol%O
10 V or 20 mA = 25 Vol%O
4
7
250 °C [482 °F] Max. (MF010)
400 °C [752 °F] Max. (MF020)
3
Bar Probe
1
2
5 V
0 V
Gas Mixture
2
2
3