DUO-TOUCH
Supply Voltage and Current
Power Consumption
Supply Protection Circuitry
Output Configuration
(including Auxiliary N.C.
output 51/52)
Auxiliary Supply Voltage
(for solid-state outputs)
Auxiliary Solid-State
Output Current
Output Response Time
Input Requirements
Simultaneity Monitoring
Period
Z1/Z2 Courtesy Voltage
Status Indicators
Housing
Mounting
Vibration Resistance
Operating Conditions
Dimensions
Safety Category
Certifications
Banner Engineering Corp.
Banner Engineering Corp.
www.bannerengineering.com • Tel: 763.544.3164
www.bannerengineering.com • Tel: 763.544.3164
®
SG –
Minneapolis MN, U.S.A.
Minneapolis MN, U.S.A.
A1-A2: 115V ac (Model AT-GM-13A) or 230V ac (Model AT-HM-13A), +/- 15%; 50/60Hz
B1-B2: 24V dc, +/- 15%, 10% max. ripple
Approx. 4 W/7 VA
Protected against transient voltages and reverse polarity
Outputs (K1 and K2): four redundant (total of eight) safety relay (forced-guided) contacts
NOTE: Transient suppression is recommended when switching inductive loads. Install suppressors
24V dc @ 1A
(between Y30 & Y31)
500 mA max., short circuit protected
(Y32 or Y31)
35 milliseconds maximum ON to OFF
Outputs from actuating devices must each be capable of switching up to 20 mA @ 12V dc.
≤ 500 milliseconds
24V dc @ 150 mA (for STB button power)
4 green LED indicators:
Power ON
Input 1 energized
Input 2 energized
Output
Polycarbonate. Rated NEMA 1 (IEC IP20)
Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated
NEMA 3 (IEC IP54), or better.
10 to 55 Hz @ 0.35 mm displacement per IEC 68-2-6
Temperature: 0° to +50°C (+32° to 122°F)
Maximum Relative Humidity: 90% @ +50°C (non-condensing)
Heat Dissipation Considerations: See page 4.
See Figure 5.
4 per ISO 13849-1; Type IIIC per ISO 13851 (EN574)
Models AT-GM-13A and AT-HM-13A Two-Hand Control Modules
across load. Never install suppressors across output contacts (see Warning on page 7).
UL approval is in process
Contact ratings:
Maximum voltage: 250V ac or 250V dc
Maximum current: 6A ac or dc (resistive load)
Maximum power: 1500 VA, 150 watts
Mechanical life: 50,000,000 operations
Electrical life: 150,000 cycles (typically @ 1.5 kVA switching power)
Specifications
1 red LED indicator:
Fault
P/N 67241 rev. C