ZN-PD50-SU Omron, ZN-PD50-SU Datasheet

no-image

ZN-PD50-SU

Manufacturer Part Number
ZN-PD50-SU
Description
Air Particle Sensor
Manufacturer
Omron
Series
ZNr
Datasheet

Specifications of ZN-PD50-SU

Tool Type
Particle Sensor
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
Air Quality
Sensor
PC Software
System Requirements
Accessories(Order Separately)
Appearance
Appearance
Appearance
OMRON Corporation
Industrial Automation Company
Sensing Devices Division H.Q.
Growth Industry Promotion Dept.
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81) 75-344-7211/Fax: (81) 75-344-7107
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen,
Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
OMRON Industrial Automation Global: www.ia.omron.com
Ordering Information
Dimensions
ZN-PD03-S
30
Item
Air Particle Sensor
Particle measurement type
Air Particle Sensor
Dust measurement type
Item
Wave Inspire ES
Item
Change filter set for
Particle measurement type
Change filter set for
Dust measurement type
Exhaust tube(4m)
Exhaust tube(8m)
Filter for cleaning
85
Air intake
(diameter=10)
OS:Windows XP, Windows Vista
CPU :Compatible with Intel processors, 1GHz or higher
Memory: 1GB or more (2GB or more recommended)
120
Input/output
terminals
AC adaptor
terminal
LAN port
10.7
Measured particle diameter Model
0.3, 0.5, or 1.0 µm min.
5µm(10µm), 20µm(30µm),
50µm min.
(
Model
ZN-SW11-S
Model
ZN9-PF1-S
ZN9-PF2-S
ZN9-PT4-S
ZN9-PT8-S
ZN9-PC1-S
)is selectable.
85.7
90.7
61
(30.7)
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark, Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
Air outlet (diameter=10)
ZN-PD03-S
ZN-PD50-S
68
(Unit:mm)
Note 1. (
Note 2. Must be used with specified AC adapter.
Item
26
Measurement method
Light source
Measured particle diameter
Particle concentration
Sample flow rate
Status outputs(2 outputs)
System error status output
Trigger Input
Communication interface
Indicators
Measure Mode
Power supply voltage
Current consumption
Ambient temperature range
Ambient humidity range
Insulation resistance
Withstand voltage
Vibration resistance
Materials
Degree of protection
Installation method
Weight (Packed state)
Accessories
Specifications
) is selectable.
Φ57.9
ZN-PD50-S
Model
30
85
(Selectable particles/cf, particles/Litter, counts of particles per measurement time)
Air-intake tube(Tubing ID : Φ10mm, Length 1m)×1
Real-time mode (by second)/Cycle mode(by set cycle)/Trigger mode(by trigger)
120
Air intake
In the interest of product improvement,
specifications are subject to change without notice.
Authorized Distributor:
© OMRON Corporation 2008 All Rights Reserved.
Cat. No. E397-E1-01(WEB1)
Operating and storage : 35% to 85% (with no icing or condensation)
7-segment sub-display(green/6 digits):Selected particle diameter
Particle measurement type
0.3, 0.5, or 1.0 µm min.
0 to 100,000particles/cf
Operating : 0 to 35˚C
Storage : -15 to 50˚C (with no icing or condensation)
7-segment main display (red/6digits):Count value
Input/output
terminals
AC adaptor
terminal
ZN-PD03-S
110 to 55 Hz, 0.3-mm double amplitude, 50 min
LAN port
2.8Litter/min
Ethernet twisted-pair cable connector (TCP/IP)
(Status outputs linked with clean levels)
90° sideways light-scattering method
10.7
Clean Levels:4levels(adjustable)
Instruction Sheet, AC adapter
1,000 VAC, 50/60 Hz for 1 min
DIN track mount / Self standing
20 MΩ min. at 500 VDC
DC19V (See note 2.)
Semiconductor laser
Photo coupler output
Photo coupler input
Approx.1.7kg
85.7
90.7
1A MAX
61
ABS
IP20
(30.7)
5µm(10µm), 20µm(30µm), 50µm min.(See note 1.)
Dust measurement type
0 to 50,000particles/cf
Operating : 0 to 40˚C
Air outlet (diameter=10)
ZN-PD50-S
Air filter ×1
6.0Litter/min
Printed in Japan
(0709) (KW)
68
(Unit:mm)
26
Cost Effective and Wide range measurement size
(From Particle to Dust)
Optimized Quality Management
with Real-time Particle
Monitoring System
Production-Environmental
Sensing Series
Air Particle Sensor
ZN-PD-S
New
The First
Dust
( 5µm to 50µm)
measurement type
Particle
measurement type
( 0.3µm to 1µm)

Related parts for ZN-PD50-SU

ZN-PD50-SU Summary of contents

Page 1

... Installation method ZN9-PT8-S Exhaust tube(8m) Weight (Packed state) Accessories Filter for cleaning ZN9-PC1-S Air-intake tube(Tubing ID : Φ10mm, Length 1m)×1 Note selectable. Note 2. Must be used with specified AC adapter. Dimensions ZN-PD03-S (Unit:mm) ZN-PD50 Φ57.9 120 85 120 85 90.7 Air intake (diameter=10) LAN port Input/output terminals ...

Page 2

... Perhaps your production environment is affected by dust? The largest form of particles, typically carried by human operators and generated by machinery. The ZN-PD50-S Particle Sensor (Dust measurement type) provides the most simple and effective solution yet for monitoring dust levels. Measure dust levels and identify dust ...

Related keywords