ZAA-2 Omron, ZAA-2 Datasheet
ZAA-2
Specifications of ZAA-2
ZAA2NC
Related parts for ZAA-2
ZAA-2 Summary of contents
Page 1
General-purpose Basic Switch Z Best-selling Basic Switch Boasting High Precision and Wide Variety • A large switching capacity with high repeat accuracy. • A wide range of variations in contact form for your selection: basic, split-contact and ...
Page 2
Model Number Legend Basic Models Actuator 1. Ratings 01: 0.1 A (micro load) None: Pin plunger 15 Slim spring plunger D: Short spring plunger 2. Contact Gap ...
Page 3
Ordering Information Basic Models (General-purpose) Classification Actuator Contact gap Terminal *1 Pin plunger Slim spring plunger Short spring plunger Low OP Panel mount plunger Medium OP High OP Panel mount roller plunger Panel mount cross roller plunger Leaf spring Roller ...
Page 4
Classification Actuator Contact gap Terminal *1 Hinge cross roller lever Unidirectional short hinge roller Parallel Z-15GW2277-B lever Reverse hinge lever *2 Reverse short hinge roller lever *2 Reverse hinge roller lever *2 *1. : Solder terminal : Screw terminal *2. ...
Page 5
Drip-proof Models Classification Contact gap Drip-proof terminal protective cover Actuator Terminal *1 Pin plunger Short spring plunger Low OP Spring plunger High OP Panel mount plunger Panel mount roller plunger Panel mount cross roller plunger Leaf spring Roller leaf spring ...
Page 6
Specifications ■ Characteristics Z-15 Classification (except micro load Item and flexible rod) 0. m/s (*1) Operating speed Mechanical 240 operations/min Operating frequency 20 operations/min Electrical Contact resistance 15 mΩ max. (initial value) 50 mΩ max. (initial value) ...
Page 7
... The AC ratings of molded terminals are 125 and 250 V only. 7. The ratings values apply under the following test conditions: (1) Ambient temperature: 20±2°C (2) Ambient humidity: 65±5%RH (3) Operating frequency: 20 operations/min 8. Consult Omron regarding CCC standards and ratings. General-purpose Basic Switch Inductive load (A) Inductive load Motor load ...
Page 8
Engineering Data ■ Mechanical Durability 10,000 Ambient temperature: 20±2°C Ambient humidity: 65±5%RH 5,000 Without load Operating frequency: 240 operations/min 3,000 1,000 500 300 100 0 0.1 0.2 0.3 0.4 0.5 ■ Structure Basic Models Contact Form (SPDT) COM NC NO ...
Page 9
Dimensions ■ General-purpose and Split Contact Models Note: Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions Terminals General-purpose Models Screw Terminals (-B) 9 ± 0.2 17.45 COM ...
Page 10
Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 ...
Page 11
Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 ...
Page 12
Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 ...
Page 13
Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 ...
Page 14
Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 ...
Page 15
Drip-proof Models (without Terminal Protective Cover) Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in ...
Page 16
Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 ...
Page 17
Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 ...
Page 18
Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 ...
Page 19
Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 ...
Page 20
Drip-proof Models (with Terminal Protective Cover) Note: Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Pin Plunger PT Z-15GA55-B5V OP 19.2 Z-15GK3A55-B5V PT OP 19.2 Panel Mount Plunger ...
Page 21
Note: Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Long Hinge Lever Z-15GW44A55-B5V 20.2 16.9 19.2 Hinge Lever Z-15GWA55-B5V 20.2 16.9 19.2 Short Hinge Roller Lever Z-15GW22A55-B5V 20.2 16.9 ...
Page 22
... VCT (vinyl-insulated cable) Note models with molded terminals are approved by UL, CSA, or EN. 2. Molded terminals are not available on all models. Contact your OMRON representative for applicable products. ■ Maintained Contact Models Note: Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. ...
Page 23
Safety Precautions Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide, “Snap Action Switches, Technical Information” for correct use. Precautions for Safe Use Terminal Connection When soldering ...
Page 24
Tightening The suitable tightening torque for screw terminals is given below. • Screw terminals except for those on Split-contact Models (Z-10FY-B): 0.78 to 1.18 N·m • Screw terminals on Split-contact Models (Z-10FY-B): 0.49 to 1.18 N·m Operation • Make sure ...
Page 25
... If an Actuator is used in a pressed state for an extended period of time at low temperatures, it may return slowly or it may not return at all. OMRON can provide special Actuators for use at low temperature with rubber boots or rubber caps made of silicon rubber, which has superior resistance to cold. Ask your OMRON representative for details ...
Page 26
... All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B ...